Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: DCSCO

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    371

    Blew out pilot feed tube and pilot assy. Good as...

    Blew out pilot feed tube and pilot assy. Good as new.
  2. Replies
    2
    Views
    371

    Robertshaw pilots do have a NG or propane orifice...

    Robertshaw pilots do have a NG or propane orifice at the pilot connection.


    Sent from my iPhone using Tapatalk
  3. Replies
    6
    Views
    503

    The furnace input = 75000 x 1450 in BTU's...

    The furnace input = 75000 x 1450 in BTU's
    Furnace output = heat content of feed water at 245 into steam at 335#, found in steam tables.
  4. Replies
    2
    Views
    371

    Pilot Flame is not what it should be

    Hello folks,

    Have a gas pilot question on a heat and glow fireplace. It's a 8000TDR Nat gas log set. The system has a powerpile and a thermocouple. The pilot flame impinges on the power pile...
  5. Replies
    25
    Views
    961

    Just two. A yellow jacket and one of those 6 d...

    Just two. A yellow jacket and one of those 6 d cell robinair thermoster models. Have the battery compartment wired shut.
  6. Replies
    17
    Views
    29,464

    Nortiz Tankless

    You gave three plumbers a try. Ask Nortiz for their district rep. If the unit is undersized, overheating would not be a problem. To descale the heat exchanger, you need an acid that disolves your...
  7. Replies
    17
    Views
    29,464

    Kellym, Find your local Nortitz rep. The guy...

    Kellym,

    Find your local Nortitz rep. The guy that trains the local plumbers and offers technical support. Explain problems, insist he come out. Also, find out from the rep, who the area...
  8. Replies
    20
    Views
    2,132

    Try moving the max temp setpoint up to 180 or...

    Try moving the max temp setpoint up to 180 or target temp down. Are the boilers step control or modulating?
  9. Replies
    1
    Views
    493

    York OT Turbo Pac, guess my weight

    Replacement time for some vintage 1979 York Turbo Pac chillers. Specifically, m/n OT C3C1B2 OJA, 250 ton units. The units are 172" overall lenght. Does anyone have the rigging weight for these...
  10. Thread: York YS chillers

    by DCSCO
    Replies
    23
    Views
    2,567

    Davo 200#'s low could mean a leak on the flange...

    Davo
    200#'s low could mean a leak on the flange to the oil seperator. I've found a leak there by the breeze of R-22 hitting my face as I pulled the insulation from the flange. Flange bolts hand...
  11. Replies
    4
    Views
    2,379

    The installations that I have seen, the back side...

    The installations that I have seen, the back side of the sterilizer, the instrument storage room, is not held to comfort cooling standards. It is exhausted and cooled by transfer air from the front...
  12. Replies
    5
    Views
    795

    Just picked up some Zurn for 1/2 and 3/4. They...

    Just picked up some Zurn for 1/2 and 3/4. They are hard for my old hands to crimp with. A rachet sounds more better.
  13. Thread: Caption this

    by DCSCO
    Replies
    22
    Views
    1,235

    If my breasts were this big, I'd get the male...

    If my breasts were this big, I'd get the male vote.
  14. Replies
    18
    Views
    1,731

    What is the problem?

    [/Quote] Over the past 7 years, I have had to replace my Trane unit twice,,,I have technicians coming to my apartment regulary to flush out the black water...nor will Trane honor the warranty on...
  15. Replies
    18
    Views
    1,731

    Your water treatment problems

    whoops
  16. Replies
    18
    Views
    1,731

    Heywood, I know that you wrote you have a closed...

    Heywood,
    I know that you wrote you have a closed loop, but just to make sure, inquire if you have a closed loop or open loop. Open loop circulates through a cooling tower. A closed loop rejects...
  17. Thread: Tools N Taxes

    by DCSCO
    Replies
    0
    Views
    353

    Tools N Taxes

    How many of us deduct tool expense from our income taxes. I've deducted tools, computer, uniform cleaning, safety items, training, licenses (fees). Am I forgetting anything? I haven't started the...
  18. Thread: Selfish Bosses

    by DCSCO
    Replies
    91
    Views
    3,408

    81 Your boss is trying to protect his...

    81
    Your boss is trying to protect his investment, you have to protect yours. Two years is too long. I would agree to one year prorated and only if you walk away from the job. You quit in six...
  19. Replies
    7
    Views
    446

    I have been with successor contractor following...

    I have been with successor contractor following LB&B. Thier contract closeout practice is hostile as opposed to professional from my limited view. However, they had the good sense to walk away from...
  20. Replies
    159
    Views
    22,750

    Get the quietest one. Put your and your...

    Get the quietest one. Put your and your coworkers working environment first. Screamers be damned. What did you say?
  21. Thread: Blood Suckers

    by DCSCO
    Replies
    16
    Views
    1,433

    They called me in New Years Day, My 56? days...

    They called me in New Years Day, My 56? days should be up shortly.
  22. Thread: York Screws...

    by DCSCO
    Replies
    11
    Views
    1,537

    If the training center still exists in York, PA. ...

    If the training center still exists in York, PA. Give them a call for the publication #'s. I remember (3) binders each for the chiller and solid state starter.
  23. Thread: Jci

    by DCSCO
    Replies
    86
    Views
    6,452

    My opinion of JCI is based on observation and...

    My opinion of JCI is based on observation and heresay and a few facts.
    JCI is a money maker. They have always provided high level returns to share holders. I believe that HVAC is the smallest part...
  24. Replies
    47
    Views
    6,636

    You have to isolate and pump de-limer. However,...

    You have to isolate and pump de-limer. However, I think that tankless only operate when water flows. Solids that form flow out with the water.
  25. Replies
    14
    Views
    1,302

    Kool, The high pressure drop mentioned was for...

    Kool,
    The high pressure drop mentioned was for the TES. Specifically, for serpentine coil in water bath type. The delta P through the chiller may be 7 of water, the TES can be more than 3 times...
Results 1 to 25 of 77
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event