  1. Replies
    52
    Views
    4,046

    That's interesting Neil. Yes lots of crap...

    That's interesting Neil. Yes lots of crap collects and the adjoining case had a plugged drain last week. But my case in question has been good. Once I took panels Nd shelves off I discovered a very...
  2. Replies
    52
    Views
    4,046

    Yes I did in post #24. And JP if you remove the...

    Yes I did in post #24. And JP if you remove the TXV and service it and even change power head why not just replace it? For the cost of time to sweat it out ( even better if they are flare), re-...
  3. Replies
    52
    Views
    4,046

    If we suspect a restriction we are changing the...

    If we suspect a restriction we are changing the TXV. It's sweat no flare
  4. Replies
    52
    Views
    4,046

    yes cant tell sometimes if site is full or...

    yes cant tell sometimes if site is full or not...system has a pump down service switch...yes site full and not bubbling...as I mentioned this store is less than 5 years old with all new equipment...
  5. Replies
    52
    Views
    4,046

    Pumped down and checked sight. Checked SH as per...

    Pumped down and checked sight. Checked SH as per manufacturer instructions. Everything bang on. My mistake on the defrost. it is 4 times a day for 40 minutes off time. Removed product, shelves and...
  6. Replies
    52
    Views
    4,046

    what can I say snapper I'm a terrible lier!...I...

    what can I say snapper I'm a terrible lier!...I do know both coils are clean...screens..I'm assuming in the TX?
  7. Replies
    52
    Views
    4,046

    Thanks guys It's a hill Phoenix 05DMH12 Off...

    Thanks guys
    It's a hill Phoenix 05DMH12
    Off time defrost 6 times daily can't remember for how long. But it was fine for 3-4 years since installed new
    What I read they want 6-8 SH at bulb. I will...
  8. Replies
    52
    Views
    4,046

    A motor up top too? Really hey? Haven't seen that...

    A motor up top too? Really hey? Haven't seen that yet. Yes one TXV. I never looked at the sight glass when I was on the roof as I just opened the electrical panel.
    Monday will have to get their...
  9. Replies
    52
    Views
    4,046

    No the fan/ fans are definitely running. I...

    No the fan/ fans are definitely running. I checked motors etc. they are definately operational. less than 5 year old hill pheniox systems. Roof top air cooled condensers. This 12 foot is on its own...
  10. Replies
    52
    Views
    4,046

    open dairy half coil freezing

    customer has a 24 foot and 12 foot open coolers side by side. the 12 foot has been having issues for last couple months. one call it was to warm. then month later to cold. problem now is approx half...
  11. So I went back and changed the cold control from...

    So I went back and changed the cold control from the original one to a habco. Superheat was ill high at 20-22 but supply temp was 35f and system shut off at 35-36 and back on at 40-42 ish. Running...
  12. From what they said nobody has touched the system...

    From what they said nobody has touched the system since the new compressor/ condensing unit was installed 4 or so months ago. Yes it's always been 134a. Ambient was around 60f round condenser.
    So I...
  13. Sorry guys guess I've confused you. The evap box...

    Sorry guys guess I've confused you. The evap box and condensing unit beside each other above cooler. Can't find a factory charge nameplate. So I was going to pull charge. See what I have. Pressure...
  14. yes it's not outdoor ambient cold, but with the...

    yes it's not outdoor ambient cold, but with the summer heat it gets quite warm in the partial attic space it is located......but as it's winter here on the west coast and not below freezing temp...
  15. no sorry...the cooler is build into a wall...evap...

    no sorry...the cooler is build into a wall...evap in an insulated box and condensing unit in unconditioned space above..as opposed to most systems we see with everything below that you can remove to...
  16. thanks...for these systems I use seperate guages...

    thanks...for these systems I use seperate guages without hoses, just quick connects so not to lose gas...yes sensing tube is mounted inside coil...it's worked fine for months...it's an older unit...
  17. beverage cooler evaporator freeze up problem

    This customer has a new air cooled condensing unit (4 months old) on this old 2 door glass cooler. critically charged cap tube system. I was called as cooler was warm. found evap frozen solid...I...
  18. The pipes are sloped properly. I pulled out...

    The pipes are sloped properly. I pulled out blower and looked at primary HX. No water or staining in housing. Some rust on ends as it meets cabnet. I'm on the wet coast. Relatively mild and wet...
  19. Oh and as far a smell in burner box it was hard...

    Oh and as far a smell in burner box it was hard to tell in the mouldy, wet and rat **** infested crawl. Yes that bad. Not to mention 2 feet clearance!
  20. Right. Never had access to our analyzer today,...

    Right. Never had access to our analyzer today, but as it is not very (3-5 years) old I wouldn't suspect HE clogged or cracked, but anything is possible. Thanks
  21. Bryant condensing furnace rollout continueous trip

    havent worked on may Bryants but this Plus 90i is horizontal left in one tight spot! There is no model or serial anywhere but it has to be a 340-AAv or 350-AAV or MAV. ANyway it continues to trip out...
Results 1 to 21 of 21