    ahh so giant air restrictive cardboard...

    ahh so giant air restrictive cardboard installation instructions and screws and the like aren't supposed to be wedged back into the coil before slapping it on top of the furnace???...
  2. Replies
    16
    Views
    2,777

    Guys teflon is the miracle cure for leaks just...

    Guys teflon is the miracle cure for leaks just "spread it on" like butter that plumbers motto was "can't see it from my house" btw;)
  3. Replies
    10
    Views
    2,192

    true, but if i can feel air commin out the vent...

    true, but if i can feel air commin out the vent and system cfms look good then i'm happy :D
  4. Replies
    45
    Views
    3,834

    Erm the general consensus is fluke, i carry fluke...

    Erm the general consensus is fluke, i carry fluke and fieldpeice only cause i don't care about the fieldpiece breaking, and i use the fluke as a backup.. incase i need accuracy...
  5. Replies
    10
    Views
    2,192

    you can use an amp meter and thermocouple running...

    you can use an amp meter and thermocouple running the systems heat strips get a temp rise and calculate cfm's by applying cfm's = (ampsxvoltsx3.413)/deltaTx1.08 loads cheaper than flowhood /...
  6. Replies
    10
    Views
    496

    almost sounds like an obstruction did you get a...

    almost sounds like an obstruction did you get a pressure reading during this phenomenon?