Search:

Type: Posts; User: tranedog

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. I really would have liked to see the wrap...

    I really would have liked to see the wrap installed per manufacture specifications to get the correct "R" value... It is suppose to have a 3/4 inch air gap between the duct and under side of the wrap...
  2. Replies
    18
    Views
    1,426

    Where are you located? We could make you...

    Where are you located? We could make you something... Empire Metal Products, Phoenix, AZ www.empiremetalproducts.com


    Sent from my iPad using Tapatalk HD
  3. Replies
    5
    Views
    793

    Copeland X reference Sent from my DROID RAZR...

    Copeland X reference

    Sent from my DROID RAZR using Tapatalk 2
  4. Replies
    5
    Views
    793

    They also have a FREE APP with that info...

    They also have a FREE APP with that info...
  5. Replies
    14
    Views
    4,037

    Are you allow to do that there??? It isn't a code...

    Are you allow to do that there??? It isn't a code violation??? Looks Great...
  6. Replies
    63
    Views
    4,929

    Yeah... God loves us SERVICE TECHNICIANS Sent...

    Yeah... God loves us SERVICE TECHNICIANS

    Sent from my DROID RAZR using Tapatalk 2
  7. Replies
    63
    Views
    4,929

    Sorry but you are incorrect! Sent from my...

    Sorry but you are incorrect!

    Sent from my DROID RAZR using Tapatalk 2
  8. Replies
    63
    Views
    4,929

    It is soooo possible to have this happen so if...

    It is soooo possible to have this happen so if anyone tells it cant they are full of crap! It not an install related problem... it is an act of God, period. You of had a Surge Protector on your...
  9. Replies
    319
    Views
    23,377

    I haven't had any problems with using it in...

    I haven't had any problems with using it in direct sun... never has gone black

    Sent from my DROID RAZR using Tapatalk 2
  10. Replies
    31
    Views
    7,951

    I worked at Service Experts it was way beyond...

    I worked at Service Experts it was way beyond corporate... the Manager was a two face b****!
  11. Replies
    319
    Views
    23,377

    Call Travis @ Tech Support they will take care of...

    Call Travis @ Tech Support they will take care of you... they are awesome! :troll2:
  12. Replies
    17
    Views
    1,481

    The main reason why the capacity starts to tank...

    The main reason why the capacity starts to tank at temperature above 95* is due to the scroll compressor not the r410a... scroll compressor just dont hold there capacity above 95* as well as...
  13. Replies
    17
    Views
    1,481

    I have been around since we use R12 in...

    I have been around since we use R12 in Residential Air Conditioning and then we went to R22 and now we are using R410a... I like working with R410a better than the rest and as long as you design your...
  14. Thread: Cooked by Cap

    by tranedog
    Replies
    1
    Views
    1,217

    Cooked by Cap

    https://plus.google.com/photos/116517504827586863327/albums/5756251585759213137?authkey=CJXc0eO6io-m5gE
  15. Replies
    6
    Views
    1,821

    Here is the link to the information regarding the...

    Here is the link to the information regarding the #9 Item i.e. Drip Guard

    https://docs.google.com/open?id=0B7bGB2quXfyoZWQ3YWIxZmItMmM1Mi00YTU5LTgwZDYtODliMzNhMTAzMGNh
  16. Replies
    6
    Views
    1,821

    9) UPFLOW AIR HANDLER BAFFLE - This baffle is...

    9) UPFLOW AIR HANDLER BAFFLE - This baffle is only included
    with Air Handler models. See note below.
    NOTE: Be careful not to discard the baffle. It is located under
    the collection cells in the...
  17. Thread: sight glass??

    by tranedog
    Replies
    42
    Views
    4,058

    The Refrigerant manufactures say... do not use a...

    The Refrigerant manufactures say... do not use a sight glass on any R-4XX blend system because they will show bubbles due to the chemistry of the blended refrigerants...
  18. Replies
    27
    Views
    2,011

    Please reference the following website- 29.92...

    Please reference the following website-
    29.92 inch Hg Vac. = 0 microns boiling point of water will be 80 F
    29.90 = 500 microns -10 F
    28.92 = 25401.07 microns
    1” Hg Vac. = 25401.07 microns

    ...
  19. Replies
    27
    Views
    2,011

    Oh BARBAR.... please read all my posts... I...

    Oh BARBAR.... please read all my posts... I stated all the exceptions and minus 10 degrees (F) at 500 microns is the boiling point of h2o (ie WATER)... And TRANEDOG has been MISTAKEN but NEVER...
  20. Replies
    27
    Views
    2,011

    you guys are hilarious.... too big of a vacuum...

    you guys are hilarious.... too big of a vacuum pump will freeze water during an evacuation... I don't know what to say about this whole thread besides... O My Gosh....
  21. Replies
    27
    Views
    2,011

    Really... really???? OMGosh...

    Really... really???? OMGosh...
  22. Replies
    11
    Views
    2,040

    AWESOME!!!

    AWESOME!!!
  23. Replies
    27
    Views
    2,011

    a vacuum lowers your boiling point temperature...

    a vacuum lowers your boiling point temperature from sea-level pressure ie. 212 degrees (F) to -10 degrees (F) at 500 microns so if you are boiling you are not freezing... da-dut-da :-)
  24. Replies
    16
    Views
    1,214

    btu test and amps

    btu test and amps
  25. Replies
    27
    Views
    2,011

    No... not if you are triple evac in cold climate...

    No... not if you are triple evac in cold climate or walk-in freeze. if you are not in a cold (freezing / wet atmosphere) then no need to triple evac just evac down to 500 micron min.