  1. Replies
    6
    Views
    263

    Typically it's the start component malfunctioning...

    Typically it's the start component malfunctioning when this happens. If that's not the problem it very would could be the pump. It's weird that it will run in low but not high. I see this on a daily...
  2. Replies
    774
    Views
    54,375

    Would there be any discounts on buying 2 of the...

    Would there be any discounts on buying 2 of the 911's and 1 each of the other 2?
  3. Replies
    27
    Views
    933

    Since it's a piston it wouldn't have a check...

    Since it's a piston it wouldn't have a check valve. Piston to large or not seating properly in the piston body.
  4. Replies
    28
    Views
    996

    Wrong Again !

    Wrong Again !
  5. +1

    +1
  6. I've been ridiculed for having "too many" or...

    I've been ridiculed for having "too many" or "don't need that" type of thing as well. Honestly, if it weren't guys/gals on this page I wouldn't know what's what ! I've witnessed on a Pro HVAC FB page...
  7. Replies
    8
    Views
    329

    Wow

    Wow
  8. Replies
    11
    Views
    673

    Very common for me as well !

    Very common for me as well !
  9. For round pipe, "I" multiply the duct x 4 and add...

    For round pipe, "I" multiply the duct x 4 and add 4. Then remove 1 1/2" of insulation to staple. For larger square or rectangular duct I add the four sides up then add 6. Always use pins on the...
  10. Replies
    25
    Views
    1,316

    You usually check delta t for a normal check. It...

    You usually check delta t for a normal check. It doesn't take long to recover a few pounds of refrigerant. You don't have the time to do it right don't do it at all . You are not doing the customer...
  11. Typically it's the the tube coming from the...

    Typically it's the the tube coming from the bottom of the liquid header. All the refrigerant then goes through the sub cooler circuit to the LLFD. I'd imagine you could re route the refrigerant...
  12. Replies
    11
    Views
    819

    Before long you will be chasing a tiny leak...

    Before long you will be chasing a tiny leak inside your Sman. It's inevitable
  13. Why isn't Hilti being discussed ? If you truly...

    Why isn't Hilti being discussed ? If you truly want the best , then this is what I recommend.
  14. Replies
    10
    Views
    437

    A & B are data / C & D are 24volt. Newer OD units...

    A & B are data / C & D are 24volt. Newer OD units only need A&B. If using communicating , there is a option to use R &G at the indoor board to monitor a float switch. It can be NO or NC and must be...
  15. Replies
    25
    Views
    835

    I simply use a toggle switch with a male and...

    I simply use a toggle switch with a male and female connector to control the fan manually .
  16. Replies
    7
    Views
    323

    We are member and have been taking the whole...

    We are member and have been taking the whole house approach. It's very informative and has helped us grow. We are now able to solve envelope issues the right way. It's definitely a learning curve and...
  17. Replies
    3
    Views
    146

    No sir ! It can only be done with a WIRED control...

    No sir ! It can only be done with a WIRED control .
  18. Replies
    5
    Views
    286

    You can defrost with or without the furnace ....

    You can defrost with or without the furnace . They have a HP lock out temp,furnace lockout temp, and defrost with furnace option. Get the install instructions for the UI your using and gain control .
  19. Replies
    71
    Views
    4,479

    Our local Carrier South Central has them at 220$...

    Our local Carrier South Central has them at 220$ plus 10% off door busters ( tools before 9 am).
  20. Replies
    71
    Views
    4,479

    Just picked up the pro PAC for just 200$. I own...

    Just picked up the pro PAC for just 200$. I own just about every tool bag known and this is hands down the best in comfort and organization . It stands up on its own unlike most . I am able to carry...
  21. Replies
    6
    Views
    396

    Yes it is !

    Yes it is !
  22. Replies
    6
    Views
    396

    Where are you reading this information ? We...

    Where are you reading this information ? We install GS systems daily with or without zoning with no major issues . Ductwork is sized for 100% capacity and the systems takes care of the rest .
  23. Thread: TEZ8

    by meh70087
    Replies
    4
    Views
    415

    The problem has been resolved by Appion . All new...

    The problem has been resolved by Appion . All new pumps . From what I understood any pump with a serial of CT13T or E13T may have a part that appion didn't approve of from one of their vendors ....
  24. Thread: TEZ8

    by meh70087
    Replies
    4
    Views
    415

    TEZ8

    What is that causes the TEZ8 to stop pulling ? Out of the 5 at our shop we are now down to 2 that will actually pull 50 microns. Mine dumped on me this evening ! They run but will not move anyone of...
  25. Replies
    3
    Views
    562

    Just attended the CM class in Houston . The ME...

    Just attended the CM class in Houston . The ME -PAD will be released sometime in the near future to take the place of these devices . It is for CM/M&P series , including the maintenance tool, and DSB...