    compu-aire troubleshooting manuals

    Does anyone have a troubleshooting manual for both the unit and the controller. i could only find installation/operation on the web site.
    i wanted to know if i can run the fan on "on" instead of...
  2. Replies
    22
    Views
    2,067

    i just had the same problem installed phase...

    i just had the same problem
    installed phase monitor- alarm on under/over voltage almost everyday.
    i thought that was causing the fuse to blow almost every two days but i finally spent time on...
  3. Replies
    22
    Views
    2,067

    I had that problem before. Almost every week the...

    I had that problem before. Almost every week the fuse blow.
    Check temp on the fuses using infared thermometer, line side and load side if there is difference in temp change the fuse holder.
  4. Replies
    17
    Views
    2,210

    Thanks time builder I will try that.

    Thanks time builder I will try that.
  5. Replies
    17
    Views
    2,210

    @BKS60, yes i have bypass the n/o contacts for...

    @BKS60, yes i have bypass the n/o contacts for the breaker of that compressor. and i swap all the relays from the 1st circuit but it still trips. i will try to spin the shaft on each cond fan...
  6. Replies
    32
    Views
    2,525

    you will need 14/3 wires. fujitsu uses high...

    you will need 14/3 wires. fujitsu uses high voltage control wires for communication on 3rd
    wire.1st and 2nd is to power the indoor unit.
  7. Replies
    17
    Views
    2,210

    @coolerguy, their is no ucp board on this system,...

    @coolerguy, their is no ucp board on this system, only relays, and timer motors for circuit 1 and 2.
  8. Replies
    17
    Views
    2,210

    @BKS60-only the 2nd circuit trips. after i reset...

    @BKS60-only the 2nd circuit trips. after i reset the system, pressures, amps, superheat and subcool is good. i'm in the process of putting a tattle tale on all the safeties. belts and filters are...
  9. Replies
    17
    Views
    2,210

    trane voyager locking out

    trane raucc60ee
    hi anyone have an idea why this trane locking out. it trips almost everyday or sometimes once a week. by the time i get the call, all the safety controls already closed. anyone has...
  10. Replies
    72
    Views
    5,338

    Please make it a habit to purge nitrogen into a...

    Please make it a habit to purge nitrogen into a brand new piping install especially on this city multi systems.