Search:

Type: Posts; User: gazoo

Page 1 of 12 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    3
    Views
    562

    thanks guys a mil...

    thanks guys a mil...
  2. Thread: Jace Serial

    by gazoo
    Replies
    2
    Views
    229

    thanks a mil....

    thanks a mil....
  3. Thread: Jace Serial

    by gazoo
    Replies
    2
    Views
    229

    Jace Serial

    is there a way to find remote jace serial number by way of workbench instead of physically seeing it on the jace itself?
  4. Replies
    1
    Views
    174

    Distech Stale Points

    i have a distech ec bos jace that is looking at proxy points in a ECP 500 gfx controller. The problem i am getting is that the points keep coming in and out of stale/ok. any ideas out there why...
  5. Replies
    3
    Views
    562

    Siemens Duct Size

    would anyone know the PPCL code for calculating CFM of a rectangular or round duct?
  6. Replies
    2
    Views
    219

    Px Button Question

    how do i get a button background to not only change color on alarm but flash also? i got the change color part but the flash part eludes me.
  7. Replies
    2
    Views
    311

    Siemens Graphic Question

    i have several floors in a building that are pretty much "cookie cutter". bunch of same type TEC 2023 or 2020. every floor has a graphic with information blocks representing temperature. my...
  8. Replies
    9
    Views
    1,047

    found the issue. the point for the damper and...

    found the issue. the point for the damper and another created point went to the same physical address but the one created from point editor was not set to L type. messed everything up. dont know...
  9. Replies
    5
    Views
    338

    Distech Double Duct

    anyone have a good double duct Ec-gFx Program that incorporates air flow and not just temp control?
  10. Thread: Circon Basic

    by gazoo
    Replies
    0
    Views
    156

    Circon Basic

    for uinteger to percent representation in a snvt_percent 32767 is auto. 20000 is 100 percent. what is the number for 0 percent and for "null"?
  11. Thread: Carrier Pilot

    by gazoo
    Replies
    6
    Views
    300

    could i get the docks please. thanks

    could i get the docks please. thanks
  12. Replies
    1
    Views
    224

    Siemens Databse Transfer?

    when i go and upload points from my panel to computer database some point give a comment of "saved in memory" while others say "saved in databse" why is that?
  13. Thread: Distech Debug

    by gazoo
    Replies
    2
    Views
    306

    Distech Debug

    i am getting the following errors when i debug a distech program:

    Too many failures when sending the Debug command to the device. Debugging has been aborted.
    Unable to send the Stop Debug...
  14. Thread: Niagara Alarm

    by gazoo
    Replies
    3
    Views
    329

    thats another issue. i get the email alarm but...

    thats another issue. i get the email alarm but the alarm console does not show an alarm.
  15. Thread: Niagara Alarm

    by gazoo
    Replies
    3
    Views
    329

    Niagara Alarm

    i keep getting an alarm that has a source of "NiagaraNetworkAlarm". i am trying to track it down. when i go to properties in niagara network last alarm showing was several days ago. i just...
  16. Thread: Niagara Spy

    by gazoo
    Replies
    2
    Views
    306

    Niagara Spy

    when i right click the station if have the option of "spy" or "spy local". what is the difference?
  17. Replies
    2
    Views
    228

    Px Browser point conversion

    i have temps in my workbench px view coming thru as F but my IE browser Px view is coming in a C. Any ideas how i get the browser to read in F?
  18. Thread: Point Precision

    by gazoo
    Replies
    2
    Views
    284

    thanks.

    thanks.
  19. Replies
    2
    Views
    280

    found the problem. the fallback had to be set to...

    found the problem. the fallback had to be set to nan. thanks for the help.
  20. Replies
    16
    Views
    492

    i had something like this happen before. one...

    i had something like this happen before. one time it was one of the boards was grounding the lan taking down several of the controllers. the other time was polarity. our controllers were being fed...
  21. Replies
    2
    Views
    280

    Tridium Numeric Writable Issue

    i right clicked a numeric writable point and put it in override. when i put it to auto the point stays in the override command percentage. any ideas out there?
  22. Thread: Point Precision

    by gazoo
    Replies
    2
    Views
    284

    Point Precision

    trying to use the program service to change the precision of points from 3 to 2 places after. any help would be appreciated.
  23. Replies
    2
    Views
    300

    got it. thanks.

    got it. thanks.
  24. Replies
    2
    Views
    300

    Px Graphic Command

    i am having trouble linking an image for a enum output point. is this possible or can you only link an image to a boolean point?
  25. Thread: Lonmaker Handle

    by gazoo
    Replies
    1
    Views
    246

    Lonmaker Handle

    i have a subsystem icon with a different handle than the subset that it takes you to. any one have an idea why?
  26. Thread: Lonmaker upgrade

    by gazoo
    Replies
    4
    Views
    411

    Does anyone have experience updating old lonmaker...

    Does anyone have experience updating old lonmaker to new turbo?
  27. Thread: Lonmaker upgrade

    by gazoo
    Replies
    4
    Views
    411

    Lonmaker upgrade

    I have an old version of lonmaker 3.01 that I have to upgrade to lonmaker turbo...I looked at echelon site but ever since they redid there web site I can't find info as easy as before... Anyone have...
  28. Replies
    9
    Views
    1,047

    im thinking more along these lines....would you...

    im thinking more along these lines....would you know the procedure for upgrading firmware? have 2.8.2 right now...
  29. Thread: tabbed pane

    by gazoo
    Replies
    7
    Views
    314

    yes. it says "CanvasPane (Root)"

    yes. it says "CanvasPane (Root)"
  30. Thread: tabbed pane

    by gazoo
    Replies
    7
    Views
    314

    the main canvass pane(root) or canvas...

    the main canvass pane(root) or canvas panes(Content) under tabbed pane?
  31. Thread: tabbed pane

    by gazoo
    Replies
    7
    Views
    314

    tabbed pane

    I have schedules set up on a tabbed pane px page. when i click the tabs for different schedules the screen does not change. anyone have an idea what is going on?
  32. Replies
    9
    Views
    1,047

    they are the older 0020,0023 controllers. Blue...

    they are the older 0020,0023 controllers. Blue covers. they are not controlled by ppcl other than day/night mode. i tried to delete and readd but still same issue persists. only when i cold start...
  33. Replies
    9
    Views
    1,047

    Siemens TEC issue

    I am having a freaky thing happening with my TEC controllers. The damper command point on all of them is going to fail. Any ideas out there as to why?
  34. Replies
    4
    Views
    378

    sorry. did not scroll far enough. you are...

    sorry. did not scroll far enough. you are correct. thanks.
  35. Replies
    4
    Views
    378

    it does not. it is not giving info as to which...

    it does not. it is not giving info as to which class the alarm is associated with.
  36. Replies
    4
    Views
    378

    Program Service Tridium

    I am trying to find which points belong to a certain alarm class. having problems. nothing comes up.
  37. Replies
    14
    Views
    875

    Yes sir

    Yes sir
  38. Replies
    14
    Views
    875

    It was provided and licensed by myself. ...

    It was provided and licensed by myself. Everything works fine on niagara side.
  39. Replies
    14
    Views
    875

    I have 15 stations pulled in. It is ditech...

    I have 15 stations pulled in. It is ditech controls supervisor. Could it be they have a different setup?
  40. Replies
    14
    Views
    875

    i wonder about this. i have 12 jaces added to...

    i wonder about this. i have 12 jaces added to tree.
  41. Replies
    14
    Views
    875

    i have device.limit="1" what would this...

    i have device.limit="1"

    what would this mean?
  42. Replies
    14
    Views
    875

    what would i look for?

    what would i look for?
  43. Replies
    14
    Views
    875

    Station Supervisor ax

    how does one know if supervisor is a small, medium, or large building version?
  44. Thread: EC BOS ?

    by gazoo
    Replies
    4
    Views
    332

    thanks very much

    thanks very much
  45. Thread: EC BOS ?

    by gazoo
    Replies
    4
    Views
    332

    EC BOS ?

    where can i find the serial number for the jace? can i find it somewhere in the workbench?
  46. Thread: tridium alarming

    by gazoo
    Replies
    1
    Views
    317

    tridium alarming

    how do you acknowledge an alarm after you force clear it from the alarm console?
  47. Replies
    18
    Views
    4,047

    in the trace...what is a U mean?

    in the trace...what is a U mean?
  48. Thread: Siemens Backup

    by gazoo
    Replies
    1
    Views
    375

    Siemens Backup

    what is the difference between "Insight Backup Utility" and "Database Transfer"?
  49. Replies
    1
    Views
    317

    Niagara Station Save

    is using the station copier in the platform the same as right clicking the station and saving station?
  50. make sure the wire is all low cap. extremely...

    make sure the wire is all low cap. extremely important. makes all the difference. Make sure that it is only grounded at one point.