  1. Replies
    1
    Views
    96

    My guess without knowing what the point is would...

    My guess without knowing what the point is would be that the controller is not allowing the point to be written to.
  2. Replies
    2
    Views
    95

    If the OCC Heat is set higher than the OCC Cool...

    If the OCC Heat is set higher than the OCC Cool that is a problem. Cool setpoint needs to be higher than heat setpoint. Recheck the occupied cool, standby cool, unoccupied cool, occupied heat,...
  3. Replies
    11
    Views
    419

    I had my cert in Richmond 8 years ago and have...

    I had my cert in Richmond 8 years ago and have seen the training material and tests of MOV and there us huge difference. Vern has an easy going personality and Richmond was like boot camp. I have...
  4. Is the old condenser a Trane? If so the control...

    Is the old condenser a Trane? If so the control transformer is usually in the condensing unit. If your original condensing unit had the transformer in it and you are using a basic thermostat like the...
  5. Replies
    11
    Views
    419

    His classes are like a vacation compared to the...

    His classes are like a vacation compared to the AX courses in Richmond. The 4 days in class in Richmond were the craziest I have ever spent.
  6. Replies
    10
    Views
    342

    That is a slick design.

    That is a slick design.
  7. Replies
    7
    Views
    319

    I thought the blue light was Kmart and the blue...

    I thought the blue light was Kmart and the blue koolaid was JCI?
  8. Replies
    7
    Views
    319

    Translation; Looking for pirated copy of software...

    Translation; Looking for pirated copy of software not available to non JCI.
  9. Replies
    11
    Views
    419

    Pre-requisite: There are pre-course study...

    Pre-requisite:
    There are pre-course study materials in the form of Computer-Based Training modules that enrolled students will need to complete before they come to class. These materials will take...
  10. Here is an option. Kele UCS-221E 2-STAGE...

    Here is an option. Kele UCS-221E 2-STAGE SEQUENCER
  11. Thermostat analog output will probably not be...

    Thermostat analog output will probably not be able to drive a DC coil of a relay. Considering the thermostat cooling output is 2-10VDC I think you may find that using a solid state relay will not be...
  12. I have seen many strainers, balancing valves and...

    I have seen many strainers, balancing valves and even connecting hoses full of rust and sludge. Pull them apart, back flushing does not always work.
  13. Replies
    3
    Views
    241

    The last ones I had with those symptoms nothing I...

    The last ones I had with those symptoms nothing I did corrected it. Ended up replacing them.
  14. Replies
    4
    Views
    357

    For an induction load I would use voltage and...

    For an induction load I would use voltage and horsepower as deciding factor.
  15. Thread: Drake Chiller

    by hvac69
    Replies
    27
    Views
    828

    Had a Carrier RTU that two out four TXV bulbs...

    Had a Carrier RTU that two out four TXV bulbs were on the wrong circuits from the factory.
  16. Thread: Drake Chiller

    by hvac69
    Replies
    27
    Views
    828

    With that much material in the driers I am...

    With that much material in the driers I am wondering what the ORI and bypass valves look like internally or if they are even operational.
  17. Thread: Drake Chiller

    by hvac69
    Replies
    27
    Views
    828

    Oh well. Not my problem anyways.

    Oh well. Not my problem anyways.
  18. Replies
    18
    Views
    739

    Is this network part of the building network or...

    Is this network part of the building network or just for hvac and now door control? If it is part of the buildings structured network they need to adhere to the network structure Which apparently...
  19. Replies
    18
    Views
    739

    There is program that is needed to change it, but...

    There is program that is needed to change it, but I have never done it though. If you also have BACnet IP devices you will have to change every device address as well that is using BACnet IP. Is this...
  20. Replies
    18
    Views
    739

    Amazing they push the issue to you when they are...

    Amazing they push the issue to you when they are the ones that caused it and would be easy for them to fix. All they need to do is address their door controller to match the existing network...
  21. Thread: Drake Chiller

    by hvac69
    Replies
    27
    Views
    828

    Model of chiller, refrigerant, self contained or...

    Model of chiller, refrigerant, self contained or split? If split, what is the length and size of discharge and liquid lines. Pressures, superheat and subcooling readings? With that pressure drop I...
  22. Replies
    14
    Views
    563

    Are the 15 stations listed under...

    Are the 15 stations listed under Station/Config/Drivers/Niagara network?
  23. Replies
    14
    Views
    563

    The license file.

    The license file.
  24. Replies
    3
    Views
    244

    The CCN driver does not support maintenance...

    The CCN driver does not support maintenance tables along with other configuration tables as you can see which ones are gray. There used to be an enhanced version driver listed, also grayed out. I...
  25. Replies
    6
    Views
    279

    The setpoint limits are not in effect if The...

    The setpoint limits are not in effect if The thumb wheel is disabled. Disabled means they can play with the setpoint until their fingers fall off and nothing will happen and your setpoints will be...
  26. Replies
    6
    Views
    279

    Not knowing exactly what controllers you have...

    Not knowing exactly what controllers you have this is an example of a typical VAV. If the high setpoint limit is set to 74 and the thumb wheel is set to 85 the active cool setpoint will be 76 and and...
  27. Replies
    27
    Views
    1,413

    I am with my 4th company in 28 years and have...

    I am with my 4th company in 28 years and have never found the one. The first one was great, but eventually I got bored after 6 years and realized I didn't want to do residential work and my boss...
  28. Replies
    11
    Views
    1,904

    Something tells me the same knitwit did both the...

    Something tells me the same knitwit did both the floor and the HVAC. Paint the trim yellow with black stripes as a warning for the trip and fall hazard.
  29. Replies
    7
    Views
    497

    Talk to someone that knows computers and have...

    Talk to someone that knows computers and have them enable JAVA.
  30. Replies
    89
    Views
    5,395

    Things happen. Normally that's what insurance is...

    Things happen. Normally that's what insurance is for. But power loss to building and or short at AC unit taking out board in MRI is more suspect than anything. Like others said how do they handle...
  31. The last time I was hurt, I tore my meniscus in...

    The last time I was hurt, I tore my meniscus in two places and required surgery. The wonderful insurance company sent me a letter stating that they felt I had case of liability against the building...
  32. Gets frustrating when people want it fixed but...

    Gets frustrating when people want it fixed but dont want too see it getting done, dont want to pay extra to get it done so no one see it getting done or is disrupted or inconvenienced. Gets worst...
  33. Thread: hvacpro

    by hvac69
    Replies
    25
    Views
    2,145

    LOL

    LOL
  34. Like I always say no matter how big the building...

    Like I always say no matter how big the building what you need to work on will be over someones desk, cubicle or head. I can understand the old office suite that has been fitted out numerous times,...
  35. Replies
    28
    Views
    1,418

    I think the sarcasm was in the first line.

    I think the sarcasm was in the first line.
  36. Replies
    7
    Views
    1,073

    I bought some directly from Flambeau for a Dwyer...

    I bought some directly from Flambeau for a Dwyer digital wet manometer and a Fluke insulation tester. Not built like a pelican style case, more like a standard pistol case, but suited my needs to...
  37. Replies
    3
    Views
    266

    CCN Setup, export data base

    CCN Setup, export data base
  38. Replies
    26
    Views
    1,820

    I have done it years ago in unit heaters at the...

    I have done it years ago in unit heaters at the instruction of my boss, with the correct wire size drill bits. Being older and wiser I dont see how much money was saved by the time I pulled them out,...
  39. PSIO are obsolete. The last story I heard as of a...

    PSIO are obsolete. The last story I heard as of a year ago, you can send them back to Carrier and they will attempt to fix and reprogram. Some serious money even if they cant fix it. The only...
  40. I would expect it to be installed in the hood as...

    I would expect it to be installed in the hood as previously stated.
  41. Replies
    8
    Views
    954

    You will need someone familiar with that...

    You will need someone familiar with that controller programming to change the damper output from the floating digital outputs to an analog. Sounds like someone installed the wrong actuator or the...
  42. If so there is usually no quantity of refrigerant...

    If so there is usually no quantity of refrigerant on the label just type.
  43. Replies
    3
    Views
    525

    If you are connecting using a web browser see...

    If you are connecting using a web browser see what version of Java you have. Anything past version 7 update 23 is an issue unless the Jace is running 3.5 or later with updated jars.
  44. Thread: VMA1420 issues

    by hvac69
    Replies
    18
    Views
    1,002

    You need to set either the common setpoint to...

    You need to set either the common setpoint to zero or the heating and cooling setpoints to zero.

    This is from the application manual.
    Actual Heating Setpoint = Heating Setpoint + Remote...
  45. Replies
    6
    Views
    1,833

    Oh yeah, I see the nice clean spot on the...

    Oh yeah, I see the nice clean spot on the housing. Oops
  46. Replies
    31
    Views
    2,870

    Magnum Research Lone Eagle I think. That an an...

    Magnum Research Lone Eagle I think. That an an XP100 were two on my to purchase someday list. I would just like the opportunity to shoot them at this point.
  47. Replies
    31
    Views
    2,870

    I purchased this about 20 years ago and installed...

    I purchased this about 20 years ago and installed the 2x scope and exotic hardwood square butt conversion grips shortly after. Have taken it hunting a couple of times but never had the opportunity to...
  48. Replies
    31
    Views
    2,870

    I had a Security Six in .357 and sold it years...

    I had a Security Six in .357 and sold it years ago to fund a Colt Python in the early 90's. I should have kept the security six as well.
  49. Replies
    6
    Views
    335

    Tristate control is a floating point control...

    Tristate control is a floating point control allowing for positions anywhere between zero and full stroke of an actuator. Power is applied to the directional contacts for a calculated length of time...
  50. Replies
    45
    Views
    2,613

    There is not enough load on the LPS monitoring...

    There is not enough load on the LPS monitoring input for the bypass timer to operate. Would need to connect a relay coil to terminal 1 and use the relay contacts across the LPS. But as discussed...