Search:

Type: Posts; User: jason12000

Page 1 of 3 1 2 3

Search: Search took 0.02 seconds.

  1. Replies
    15
    Views
    630

    Replace with 410. It's a blend so how much of...

    Replace with 410. It's a blend so how much of which are you reusing. Filter on the outside and replace with copper is an excellent idea. Blow out piston and clear screen while you have an open...
  2. Replies
    7
    Views
    601

    Mark an outline in hidden areas and photograph...

    Mark an outline in hidden areas and photograph it. Write on the paperwork if unit is moved or tampered with in any way this will void all warranties, and all visits and charges will apply.

    Sent...
  3. Replies
    13
    Views
    770

    At least you got WB readings. Try taking the txv...

    At least you got WB readings. Try taking the txv bulb off and see if anything changes. SH, SC, airflow correct?

    Sent from my SM-G920V using Tapatalk
  4. Replies
    24
    Views
    1,178

    695961 Sent from my SM-G920V using Tapatalk

    695961

    Sent from my SM-G920V using Tapatalk
  5. Replies
    11
    Views
    650

    That's a fixed orifice wearing a hat. Sent...

    That's a fixed orifice wearing a hat.

    Sent from my SM-G920V using Tapatalk
  6. Replies
    49
    Views
    2,478

    Before I add refrigerant to a system I always...

    Before I add refrigerant to a system I always check airflow. Does that thermometer of yours have a CFM button on it?

    Sent from my SM-G920V using Tapatalk
  7. Replies
    12
    Views
    669

    Check the fan blades for mold/mildew build up....

    Check the fan blades for mold/mildew build up. Low airflow will give a code of low refrigerant. Most newer models have sensors for the coils and won't let it get to the icing up stage. Brand? Model?...
  8. Thread: More heat!

    by jason12000
    Replies
    13
    Views
    1,463

    Needs another coupling, that'll fix it. Sent...

    Needs another coupling, that'll fix it.

    Sent from my SM-G920V using Tapatalk
  9. Replies
    18
    Views
    1,026

    Redline looks sweet. I had a mongoose among...

    Redline looks sweet. I had a mongoose among others. Nice post.

    Sent from my SM-G920V using Tapatalk
  10. Replies
    16
    Views
    1,376

    Recommendations from teachers is a plus. You...

    Recommendations from teachers is a plus. You don't have the bad habits other techs have picked up over the years. The new employer can mold you how he wants you to be. At least as much as you agree...
  11. Replies
    2
    Views
    560

    http://images.tapatalk-cdn.com/15/07/31/3bdcaa27fe...

    http://images.tapatalk-cdn.com/15/07/31/3bdcaa27fe6cd10fde3bb8fe8d4d1bc5.jpg

    Sent from my SM-G920V using Tapatalk
  12. Thread: Tap a talk

    by jason12000
    Replies
    0
    Views
    367

    Tap a talk

    I am a pro member but can't access it through tap a talk. I see the pro sub forum, but only get the announcement. Help.

    Sent from my SM-G920V using Tapatalk
  13. What a great thread. I had to replace a txv on...

    What a great thread.
    I had to replace a txv on an evap. two other techs from our co. had misdiagnosed. When I finished and showed the customer that everything was working, she tipped me $100. Long...
  14. Replies
    21
    Views
    4,064

    I had heard about the supco's performing this way...

    I had heard about the supco's performing this way a while back and switched to the compressor defender. I haven't experienced any failure like this one. The first thing they are going to say is...
  15. Thread: HVAC Agent

    by jason12000
    Replies
    8
    Views
    1,986

    sorry, double post

    sorry, double post
  16. Thread: HVAC Agent

    by jason12000
    Replies
    8
    Views
    1,986

    I still use that site just in case, but it seems...

    I still use that site just in case, but it seems craigslist is the best resource. Also try Industry papers like Indoor Comfort, or something from the local supply houses.
  17. Replies
    4
    Views
    891

    Got rain gear. Any advice on weather proof tool...

    Got rain gear. Any advice on weather proof tool bags and the like.
  18. Replies
    4
    Views
    891

    Moving to Oregon. Need advise.

    I'm going to be moving to Portland, OR, from CA and wanted advise on equipment differences. Are there a lot more oil furnaces, boilers, geo thermal, etc. I'm BPI, NATE, NCI cert. just not familiar...
  19. Replies
    18
    Views
    6,637

    Thanks for sharing. Those are really cool.

    Thanks for sharing. Those are really cool.
  20. Replies
    27
    Views
    3,914

    Is this only on 22 to 410a change outs or all...

    Is this only on 22 to 410a change outs or all installs?
  21. Replies
    39
    Views
    9,094

    Beautiful work. An eye for detail as it should be.

    Beautiful work. An eye for detail as it should be.
  22. Replies
    57
    Views
    9,086

    Let's check the compressor trap and see if we...

    Let's check the compressor trap and see if we caught anything? Hey, it worked.
  23. Thread: Fujitsu

    by jason12000
    Replies
    14
    Views
    2,515

    When you are in front of the system call tech...

    When you are in front of the system call tech support. They will have you remove the #3 wire and test wire to terminal and wire to ground both at the indoor and outdoor to determine if communication...
  24. Replies
    1
    Views
    1,103

    Yes they work. Best if you have a variable speed...

    Yes they work. Best if you have a variable speed blower to circulate air for continuous effect. It will neutralize viruses, bacteria, mold, and odors. Make sure you have a qualified professional...
  25. Replies
    32
    Views
    4,697

    I have one C&D and one Robinair. Used both for...

    I have one C&D and one Robinair. Used both for years and haven't had a problem with either.
  26. Replies
    51
    Views
    6,682

    Up sizing is acceptable to an extent, but...

    Up sizing is acceptable to an extent, but capacitor ratings are to simulate 3 phase operations in a single phase motor. So yes, change it to the right one.

    Sent from my SCH-I535 using Tapatalk
  27. Only qualified professionals should charge...

    Only qualified professionals should charge systems. The pink line has been crossed.

    Sent from my SCH-I535 using Tapatalk
  28. Replies
    12
    Views
    2,016

    I sent in my sman3 manifold recently. Blank...

    I sent in my sman3 manifold recently. Blank screen, out of warranty. I was totally expecting to bite the bullet and get a new one. They sent me a new one no problem. I originally had the blue and red...
  29. Replies
    32
    Views
    4,062

    I would read the section in your text book about...

    I would read the section in your text book about latent heat, and sensible heat removal. Go over that until it makes sense. Then go to a psychrometric chart and mull over it there as well. Don't...
  30. Replies
    12
    Views
    2,382

    Nylog is great, but it's used to make a seal of...

    Nylog is great, but it's used to make a seal of connections that could be leak proof without it. It's worth a shot, but not a substitute for repair or replace.
  31. Thread: Mini splits

    by jason12000
    Replies
    29
    Views
    3,898

    kklobas, mr_guy, amd mason have giving very good...

    kklobas, mr_guy, amd mason have giving very good info. Mini's are not to be treated like a normal system. If you are doing several at the property over the span of a week or two, you'll have it down...
  32. Thread: Mini splits

    by jason12000
    Replies
    29
    Views
    3,898

    If its multilevel apartments, just carefully map...

    If its multilevel apartments, just carefully map where your line set runs go. Try to color code or label by apt. number, and keep the flare fittings accessible (not in a wall between floors). If you...
  33. Replies
    12
    Views
    1,741

    When I read the title I thought it was going to...

    When I read the title I thought it was going to be this http://www.eurekalert.org/features/doe/2002-01/dl-nmr061702.php
  34. Replies
    11
    Views
    1,967

    The compact swag tool by Hilmor has been on my...

    The compact swag tool by Hilmor has been on my list as well. If you get it let me know what you think. If anyone else has one please chime in.
  35. Replies
    20
    Views
    2,784

    I only offer the NCI model. I explain the...

    I only offer the NCI model. I explain the difference to the home owner and let them decide. Yes, I offer it to every gas appliance owner. I wouldn't sell them something that i wouldn't put in my own...
  36. Replies
    48
    Views
    9,962

    Most of the general public isn't aware of NATE....

    Most of the general public isn't aware of NATE. Also, most people aren't aware of NCI, ACCA, ASHRAE, HVAC Excellence, or BPI. That doesn't mean they aren't important. Our company has landed quite a...
  37. Replies
    48
    Views
    9,962

    Probably not updated yet. Give it time. You'll...

    Probably not updated yet. Give it time. You'll get certs in the mail. If it doesn't change in a week, send them an email. Valerie Briggs will take care of it. Congratulations.
  38. Thread: HSI HELP

    by jason12000
    Replies
    23
    Views
    3,335

    Test the ones you have on you truck. Write those...

    Test the ones you have on you truck. Write those ohm readings down. As you replace with OEM parts, test the bad ones and make a cheat sheet of your own.
  39. Replies
    59
    Views
    8,495

    As your copper line gets ready to receive the...

    As your copper line gets ready to receive the brazing rod you're torch flame turns greenish. Move the torch tip to your stub, still pointing away from your compressor, but heat must be applied to the...
  40. Replies
    5
    Views
    988

    0-1" is best for resi. You can use it for light...

    0-1" is best for resi. You can use it for light com. also, just measure supply and return separately then add results together for TESP.
  41. Replies
    59
    Views
    7,325

    That is a mighty mustache. I understand the cut...

    That is a mighty mustache. I understand the cut back for summer, but heating season is upon us and only a proper roll out can keep the stache short in cold weather. I feel another thread emerging.
  42. Replies
    59
    Views
    7,325

    Shirt pocket: Smart phone and pen Shirt pocket:...

    Shirt pocket: Smart phone and pen
    Shirt pocket: 2 Fieldpiece thermometers, t-stat screw driver
    Pants pocket: keys (duh)
    Pants pocket: misc. paper from back of foil tape, burned fuses, left over...
  43. Replies
    41
    Views
    5,444

    parallel=plus series=subtract and yes, verify...

    parallel=plus
    series=subtract
    and yes, verify with a meter.
    easy peasy.
  44. 10% variation on supplied voltage. The motors...

    10% variation on supplied voltage. The motors don't know if they are heat pump or straight cooling?
  45. Replies
    13
    Views
    1,674

    replace the 9V.

    replace the 9V.
  46. Replies
    16
    Views
    3,359

    That's very true. My main point is to inform the...

    That's very true. My main point is to inform the customer if it needs to be removed more costs will incur. I've found it's better to charge them up front then to go back a few weeks later and drop...
  47. Replies
    2
    Views
    820

    Thanks Jim, I did mean the 605-H2. I switched it...

    Thanks Jim, I did mean the 605-H2. I switched it back. It made me realize how much I use it.
  48. Replies
    21
    Views
    2,173

    Yes to the RSES book. The Dewalt one is good...

    Yes to the RSES book. The Dewalt one is good also. Taking a class geared for the NATE test is extremely helpful. Knowing the info. is one thing, but knowing how to take the test is another. The...
  49. 30* above ambient, as stated earlier, doesn't...

    30* above ambient, as stated earlier, doesn't apply to all systems, or all conditions. SH and SC tells you so much more. Break the chains of schooling and find other forms of info. This site, NATE...
  50. Replies
    2
    Views
    820

    Testo Hygrometer stuck in C*

    Anyone know how to change the testo 502 Hygrometer from C* to F*. I don't have the manual on me, and it switched in my bag. Thanks
Results 1 to 50 of 146
Page 1 of 3 1 2 3