04-30-2009, 01:50 AM
Thread: Gas Fireplace Expansion Noise?
by Tin_Courier- Replies
- 9
- Views
- 1,817
Exp. noise in an Infinity
I've just run into a bad expansion noise in a multiunit condo tower. We sold Infinities for all the units (~50), and the builder used their own sub to install them. We got a call for the 1-year...
-
12-27-2008, 01:31 PM
Thread: avalon "tree of life"
by Tin_Courier- Replies
- 4
- Views
- 815
You can find the manual on the Avalon website ...
You can find the manual on the Avalon website
http://www.avalonfirestyles.com/TravisDocs/100-01169_001.pdf -
12-21-2008, 02:38 PM
Thread: Heatilator Hi/Lo Flame
by Tin_Courier- Replies
- 11
- Views
- 2,720
I agree. If you have a RCT-MLT installed, or any...
I agree. If you have a RCT-MLT installed, or any other control with electronic adjustment of manifold pressure, the first step is to check manifiold pressure with a manometer. When the solenoid was...
-
12-18-2008, 01:17 AM
Thread: intermittent vs standing pilot
by Tin_Courier- Replies
- 3
- Views
- 4,000
Late to the party. Our shop sells almost...
Late to the party. Our shop sells almost exclusively IPI systems from mfg's that offer them. As far as I know, H&G doesn't offer inserts in IPI. I'm a fan of the system, even if it does give up...
-
12-17-2008, 05:22 PM
Thread: "Delayed" Ignition on SL-750
by Tin_Courier- Replies
- 17
- Views
- 1,316
SP - turn out one of my other meters, an ExTech,...
SP - turn out one of my other meters, an ExTech, will measure uAmps. I agree, doesn't seem to be the issue here, but I've been playing around on other units to get familiar, kind of a fun gadget.
-
12-17-2008, 05:17 PM
Thread: DV ghosting troublshooting idea
by Tin_Courier- Replies
- 8
- Views
- 822
Thanks for the good ideas and questions,...
Thanks for the good ideas and questions, everybody. Great info, HM.
Sorry to take so much time responding. I think I got it, though. I was barking up the wrong tree, though. The last tech... -
12-13-2008, 04:58 PM
Thread: "Delayed" Ignition on SL-750
by Tin_Courier- Replies
- 17
- Views
- 1,316
Sorry HM, didn't click through to the 2nd screen....
Sorry HM, didn't click through to the 2nd screen. It's possible it's a spark issue, but honestly I'm not sure how to diagnose that(besides visually) short throwing parts at it.
The spark looked... -
12-13-2008, 04:44 PM
Thread: DV ghosting troublshooting idea
by Tin_Courier- Replies
- 8
- Views
- 822
DV ghosting troublshooting idea
Has anybody ever tried pulling a partial vacuum in DV pipe with a shop vac and measuring the negative pressure inside the vent with a manometer to identify breaks or faults in the venting?
I have... -
12-13-2008, 04:27 PM
Thread: Quadrafire blower cycles on & off
by Tin_Courier- Replies
- 2
- Views
- 548
That should be pretty straightforward for the...
That should be pretty straightforward for the tech to pin down. With the wiring diagram for the insert, the they should be able to trace the blower wiring and find the fault.
-
12-13-2008, 03:02 PM
Thread: "Delayed" Ignition on SL-750
by Tin_Courier- Replies
- 17
- Views
- 1,316
Thanks for the input, everybody. SP- I hate...
Thanks for the input, everybody.
SP- I hate to admit it, but I've never done that kind of test on rectifier current. I use a Fluke 111 for most of my work, and I know that won't read microamps.... -
12-12-2008, 06:00 PM
Thread: "Delayed" Ignition on SL-750
by Tin_Courier- Replies
- 17
- Views
- 1,316
I've seen that before, too. A lot of times it...
I've seen that before, too. A lot of times it seems to help to polish the sensor rod and ground strap (if present) with fine sandpaper. These SL's, though, had a delay before the pilot would light,...
-
12-12-2008, 10:33 AM
Thread: Two Bad Millivolt Generators
by Tin_Courier- Replies
- 8
- Views
- 875
Yeah, I've seen quite a few TP's and several TC's...
Yeah, I've seen quite a few TP's and several TC's tht failed only under load, and have to be tested into a load to see the fault on a meter.
To save time, I made a little 2ohm shunt resistor on... -
12-12-2008, 09:04 AM
Thread: "Delayed" Ignition on SL-750
by Tin_Courier- Replies
- 17
- Views
- 1,316
Hearth-Incoming pressure is 5.94, drops to 5.15...
Hearth-Incoming pressure is 5.94, drops to 5.15 under load. I didn't check the pilot orifice, but from loooking at the pilot flame, it's definitely not an LP orifice, and the pilot looks strong. If...
-
12-12-2008, 08:55 AM
Thread: "Delayed" Ignition on SL-750
by Tin_Courier- Replies
- 17
- Views
- 1,316
JTP-The delay is only from a cold start, and the...
JTP-The delay is only from a cold start, and the spark is nice and strong. I haven't seen any issue with pilot stability of intermitent operation, just the initial cold delay.
SP- I've seen some... -
12-11-2008, 09:09 PM
Thread: "Delayed" Ignition on SL-750
by Tin_Courier- Replies
- 17
- Views
- 1,316
"Delayed" Ignition on SL-750
Hi Guys,
Just wanted to get some other opinions on this. I had a wty. call yesterday for 2 identical SL-750 TRS-IPI-E's that we installed several months ago. Cust. complained, "There's a 10-12... -
12-29-2006, 06:24 PM
Thread: lyemance damper
by Tin_Courier- Replies
- 4
- Views
- 582
I'm not sure I follow. This is a damper cap,...
I'm not sure I follow. This is a damper cap, right? Pull a cable inside the fireplace and it seals at the top, that kind of thing?
When you say condensation on the door, do you mean a glass... -
12-29-2006, 05:01 PM
- Replies
- 5
- Views
- 589
I think it's going to get worse before it gets...
I think it's going to get worse before it gets better, as far as servicability goes. With more interest lately in clean-face units and alternate layouts, valves are getting kind of tricky to get to...
-
12-29-2006, 04:55 PM
- Replies
- 30
- Views
- 4,775
I agree. I've found that typically, unless the...
I agree. I've found that typically, unless the bulb of a TC has burst, the TC is not the problem. Weak or drifting pilot is far more common, IMHO
TP's are the same way. Most of the time it's...