Search:

Type: Posts; User: Vettgetsmwet04

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Replies
    59
    Views
    10,643

    at least they stepped up and addressed the issue,...

    at least they stepped up and addressed the issue, its better than the black tape on my 510 and 605.
  2. Replies
    147
    Views
    19,591

    both my fluke pk-80 have a bad connection right...

    both my fluke pk-80 have a bad connection right at the plug, where it hangs down, i can wiggle it and it will work. just got new clamps, im gonna get some heat shirnk wrap and make it stronger so it...
  3. Replies
    147
    Views
    19,591

    i use the fluke pk-80 on the suction, and...

    i use the fluke pk-80 on the suction, and fieldpiece atcr1 on the liquid line, they work great, but after about 12-14 months ive had to replace them dur to a weak wire connection on the fluke, and a...
  4. Replies
    147
    Views
    19,591

    i dont like to listen to the olds guys opionion...

    i dont like to listen to the olds guys opionion on tools at my work, im 28, they think i waste money on all my nice highly accurate tools. but whats funny is im 30-40% more productive and have a far...
  5. Replies
    147
    Views
    19,591

    the problem with all digital gauges is the temp...

    the problem with all digital gauges is the temp clamps or straps.

    between all the guys i work with we have many sets of all the various types, i own the sman 3 and testo 550.

    i use my sman 3...
  6. Replies
    8
    Views
    1,457

    yea, the fieldpiece leads are shorter than fluke...

    yea, the fieldpiece leads are shorter than fluke leads, i use fluke leads with me fieldpiece meters for the longer reach, and i like the fact that they are one piece, the fieldpiece leads come apart...
  7. Replies
    4
    Views
    878

    on commercial units with a high static u wont see...

    on commercial units with a high static u wont see much over 2 inches to 3 inches
  8. Replies
    4
    Views
    878

    get the testo 510, it will measure up to 40...

    get the testo 510, it will measure up to 40 inches of water column, alot more than one would ever need.

    u can use it for gas pressure and pressure switches as well, very good price, and high...
  9. Replies
    10
    Views
    1,261

    I used the sc 77 for the past 3 years, its a...

    I used the sc 77 for the past 3 years, its a backup to my sc 56 now, but thr 77 was flawless, either will be a good decision, well worth the money, ive never used any other brand, so I cant comment...
  10. Replies
    10
    Views
    1,261

    Fieldpiece sc 56, it does everything

    Fieldpiece sc 56, it does everything
  11. I have the testo 605 and the new fielpiece prh2...

    I have the testo 605 and the new fielpiece prh2 pocket unit. They are within a couple tenths on all measurements. So far I like the fieldpiece, will see how it holds up.

    Most digital physchometers...
  12. Replies
    24
    Views
    2,649

    Yea the problem with low loss fittings is the...

    Yea the problem with low loss fittings is the pressure of 410 is to high for them to hold up, that's all mywork would buy, but they keep failing on 410 high side. Stick with ball valves.
  13. Replies
    5
    Views
    2,007

    Fpm x area in square feet of duct

    Fpm x area in square feet of duct
  14. Replies
    30
    Views
    2,408

    10 years from now analouge will not exist, or of...

    10 years from now analouge will not exist, or of it does it will be hard to find, like trying to find a analouge multimeter.

    the problem is now there new, not alot of research and time put into...
  15. Replies
    25
    Views
    1,332

    the few times i used mine for a vac mine went to...

    the few times i used mine for a vac mine went to 32"hg
  16. Replies
    3
    Views
    661

    the g5 twin is by far the best recovery machine...

    the g5 twin is by far the best recovery machine ive ever used, the fastest and smallest.

    i dont know about all the techinicals, but ive had mine for about a year and its much faster than all the...
  17. Replies
    204
    Views
    28,618

    fieldpiece sc77, use it on every call, has never...

    fieldpiece sc77, use it on every call, has never let me down in 3 years
  18. Replies
    161
    Views
    54,090

    here ya go ...

    here ya go

    http://www.trutechtools.com/Vacuum-Rated-Valve-Core-Removal-Tool_p_967.html
  19. Replies
    161
    Views
    54,090

    i used my yellow jacket core removers before i...

    i used my yellow jacket core removers before i got the appion, never had a problem pulling a deep vacuum with them, but the appions are much nicer to use and i know they are rated for the job.
  20. Replies
    161
    Views
    54,090

    appion is vacuum rated to 20 microns, yellow...

    appion is vacuum rated to 20 microns, yellow jacket isnt vacuum rated
  21. Replies
    7
    Views
    996

    mine was down to 2 bars after 4 months of none...

    mine was down to 2 bars after 4 months of none stop usage, finally chaged them last week.

    seems u diff have a issue, russ will take care of it
  22. Replies
    8
    Views
    2,597

    sounds good, might be able to get the bossman to...

    sounds good, might be able to get the bossman to go for a couple of those
  23. Replies
    41
    Views
    6,362

    it reads negative and positive pressure, u just...

    it reads negative and positive pressure, u just have to be smart enough to know if what your measuring is a negative or positive pressure. left side is positive, right side is negative.

    what good...
  24. Replies
    4
    Views
    854

    Yep, testo 435 will calculate capacity, very...

    Yep, testo 435 will calculate capacity, very expensive
  25. Replies
    161
    Views
    54,090

    id use this...

    id use this
    http://www.hvacr-tools.com/product/yellow-jacket-15012-plus-ii-1-4-heavy-duty-hose-str-x-45-deg-12
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event