  1. Thread: JCI dsc 8500

    by bedlite2
    Replies
    12
    Views
    1,948

    I will copy it for you. Give me an email address...

    I will copy it for you. Give me an email address and I'll send it to you. Your right about the jumpers. One set is for the address and the other is for communication speed.
  2. Thread: JCI dsc 8500

    by bedlite2
    Replies
    12
    Views
    1,948

    Did you ever het a manual for cal1?

    Did you ever het a manual for cal1?
  3. Thread: JCI dsc 8500

    by bedlite2
    Replies
    12
    Views
    1,948

    I have my tech school books if your interested in...

    I have my tech school books if your interested in buying them, or I could copy the section on FIC boards if that would help. I also have the cal1 one book.
  4. Replies
    5
    Views
    860

    Unless I am mistaken, even with PMI the GPL in...

    Unless I am mistaken, even with PMI the GPL in the NCM is object code and without the origional GPL there is no way to know what it was suppose to do. I could be wrong. I was once last...
  5. Replies
    13
    Views
    894

    You mentioned that your occupied status is true. ...

    You mentioned that your occupied status is true. What about your fan status? Might make sure that it matches your data base, ie BI #? matches what is mapped into the HVAC Pro. I have also ran into...
  6. Replies
    7
    Views
    1,390

    How old of a system do you have. Do you have a...

    How old of a system do you have. Do you have a program called HVAC Pro. If so you can calibrate from it. If you have the blue screen then it is PMI software, web based then your looking at the cct...
  7. Replies
    12
    Views
    689

    I am also assuming that you are using the same...

    I am also assuming that you are using the same arcnet board, and other ncm's are talking,otherwise nothing would be talking if the board was set up incorrectly.
  8. Replies
    12
    Views
    689

    I assume you have checked that the ncm is set up...

    I assume you have checked that the ncm is set up correctly in the ddl files in global? can you connect to it with metasys off and using winset? Just some quick thoughts.
  9. Replies
    12
    Views
    689

    Was the system working with the old computer...

    Was the system working with the old computer before it crashed?
  10. Replies
    0
    Views
    478

    Marvair Thermostat

    I have come across some Marvair units I have to take care of. They have the Marv5000 t'stats on them. Anyone used these before and what kind of luck have you had. Thanks for any input.
  11. Replies
    13
    Views
    2,450

    e-mail is in public profile.

    e-mail is in public profile.
  12. Replies
    22
    Views
    1,718

    One thing to remember about saving the DB. If...

    One thing to remember about saving the DB. If you have on old one there, another one will not overwrite it. The systems says that it failed. You have to erase the old one and then run the save_db....
  13. Replies
    13
    Views
    2,450

    This is yur lucky day. I have the pimload...

    This is yur lucky day. I have the pimload program. Found it with all my old DSC programs.
  14. Replies
    22
    Views
    1,718

    Unless I am mistaken you may want to think about...

    Unless I am mistaken you may want to think about changing the battery or put a UPS on it. Something to hold the program during power failure. Like Bill said, Murphy will hit you at the worst time.
  15. Replies
    0
    Views
    326

    ethernet to arcnet adapter

    I have the new JCI ethernet to arcnet box tied into a system. All the NCM's are defined in the box as well as the archive computer. My problem is when I hook up a second workstation to the ethernet...
  16. Thread: Ice Cold

    by bedlite2
    Replies
    3
    Views
    1,691

    Ice Cold

    Has anyone used a new oil additive called "Ice Cold"? They say it is suppose to really work well and save compressors and make them more efficient. Anyone used this?
  17. Thread: Cold shot

    by bedlite2
    Replies
    4
    Views
    603

    Cold shot

    Has anyone used a new oil additive called "Ice Cold"? They are telling us about how great it works and I thought I would get on here and ask fellow experts. Thanks.
  18. Replies
    3
    Views
    786

    I agree. I finally talked them into giving me a...

    I agree. I finally talked them into giving me a machine with straight XP and things went smoth as silk. Thanks all for the help.
  19. Replies
    3
    Views
    786

    JCI Metasys on XP

    Has anyone had good luck setting up Metasys PMI software on a Vista Machine with Windows XP 64 bit emulation? I was told it doesn't work?
  20. Thread: JCI dsc 8500

    by bedlite2
    Replies
    12
    Views
    1,948

    dsc 8500

    I have the manuals from a long time ago. Is there a particulat problem your dealing with that I can help on. Just let me know.
  21. Replies
    8
    Views
    1,687

    Sorry I didn't know you had to purchase it. That...

    Sorry I didn't know you had to purchase it. That means I cannot upload it to you. Sorry.
  22. Replies
    8
    Views
    1,687

    Try this.

    Try this.
  23. Replies
    8
    Views
    1,687

    If he cannot do it let me know and I will zip up...

    If he cannot do it let me know and I will zip up something that will work. It is all part of HVAC Pro and is a free program, best I remember.
  24. Replies
    0
    Views
    809

    Kivic Controls

    Has anyone had any dealings with KIVIC controllers. We are thinking of putting them in I would like some input. Thanks guys.
  25. What kind of program are you running in the UNT? ...

    What kind of program are you running in the UNT? Will a sideloop not work or if your wanting to fake an outside air sensor on the UNT johnson temps are 70 degf @1k. Then it is 3 ohms per degree...
  26. Replies
    4
    Views
    654

    If you do happen to get the nae, have you got the...

    If you do happen to get the nae, have you got the software to program them. If so ehoot me an e-mail and I may have a source where you can buy them.
  27. Thread: JCI EPT-102-1

    by bedlite2
    Replies
    6
    Views
    949

    Feedback isn't necessary, but helpful for anyone...

    Feedback isn't necessary, but helpful for anyone looking at the ept.
  28. Replies
    13
    Views
    1,287

    I have 9 NCM's. Most the 100 series and only one...

    I have 9 NCM's. Most the 100 series and only one 350. Large network but is all running on arcnet. I am trying to get it to ethernet, or atl east upgrade what I have now till they can afford to...
  29. Replies
    13
    Views
    1,287

    Johnson Controls Software

    I have an existing JCI system with various types of controllers and am looking to upgrade the front end. Looking at Tridium but wanted to see what everyone else is using that is compatable with JCI...
  30. Replies
    8
    Views
    1,050

    Controllers are not networked, but after further...

    Controllers are not networked, but after further reading of the display panels book I found that I could unplug their dc source and then just use the inputs as a straight plus and minus. Source from...
  31. Replies
    8
    Views
    1,050

    I have a 2 wire 4-20ma sensor and trying to hook...

    I have a 2 wire 4-20ma sensor and trying to hook it up to two different displays. Each has power out and an input.
  32. Replies
    8
    Views
    1,050

    Power supplies DC

    I am having a brain freeze. If I hook up two seperate dc poer supplies one 24vdc and the other 12vdc in series won't I get 24vdc and the current capacity of both power supplies? Having aheck of a...
  33. Thread: JCI dsc 8500

    by bedlite2
    Replies
    12
    Views
    1,948

    After many years of working on them, let me know...

    After many years of working on them, let me know what you are questioning and I may be able to help you.
  34. I worked for JCI for 25 years. Started with the...

    I worked for JCI for 25 years. Started with the pneumatic controls and moved on from there. You would be surpised how many techs now don't understand pneumatics.

    Anyway for years the us service...
  35. Replies
    7
    Views
    1,445

    I wonder if the AO for the supply damper has...

    I wonder if the AO for the supply damper has anything to do with the Fire Alarm system? Closing the damper in case of fire or maybe for a Purge operation? Just some other ideas.
  36. Replies
    9
    Views
    2,068

    Oh Well

    Re-compiled net global and nc all with no problem. Global was already downloaded in laptop. Sending to nc but getting nothing in return. Path in the Metasys INI file is ok too. Oh well, that is...
  37. Replies
    9
    Views
    2,068

    Did not run Prep For. Using the defaults when...

    Did not run Prep For. Using the defaults when the PMI was loaded. Should I run it, didn't think I had to undless using another directory?
  38. Replies
    9
    Views
    2,068

    NCM 350 and PMI

    I have been trying to get a laptop loaded with JCI PMI 12.0 software to talk to an NCM 350 over ethernet. Set up the IP addresses, node and all that stuff thru wnsetup. Made changes to Metasys INI...
  39. Might be interested. sent you a friend request...

    Might be interested. sent you a friend request then we can talk. Take care.
  40. Replies
    5
    Views
    920

    If your still having problems let me know. Many...

    If your still having problems let me know. Many years with Johnson as a tech, i can probably get you thru it.
  41. Replies
    28
    Views
    3,890

    front panel

    You can change parameters from the front panel. Let me know and I will get you an explaination sheet to you with what you need to do. Programming is another matter, but parameters you can change,...
  42. Replies
    11
    Views
    1,265

    I am going to guess you will have to reprogram ....

    I am going to guess you will have to reprogram . If you can't read the cal1 program let me know and I will translate it into plain english for whoever has to program the FX unit.
  43. Replies
    11
    Views
    897

    time and date

    Best I can remember, after you login and under user views the first item under that view is the NCM. double click or drag it to the right hand screen and then hit the edit button on top. This...
  44. Thread: JCI GPL

    by bedlite2
    Replies
    8
    Views
    1,404

    gpl

    Yes I am running 12.04 PMI. I tried going to program manager using the dos prompt. I get a totally blank screen. Tyoe in EXIT and I go back to program manager. I am using a wireless mouse and I...
  45. Thread: JCI GPL

    by bedlite2
    Replies
    8
    Views
    1,404

    JCI GPL

    I have a system on a computer, running Windows XP, with PMI ethernet based. Whenever I try and go to the GPL screen the program opens up the dos window then goes back to the main screen. I have...
  46. Replies
    11
    Views
    957

    know the feeling

    I totally understand. I was the same way over 25 years ago. I stayed with them and learned all I could. Now the problem is that the new guys only know the newer systems and don't understand the...
  47. Replies
    6
    Views
    844

    Sn. Project Manager

    I have the programs you looking for, and the adapter I do not have. You can download from the Operator Workstation but it is slower. Unless you have the .cal program there is no way to see how it...