  1. Replies
    11
    Views
    794

    Sounds like the furnace isnt grounded properly....

    Sounds like the furnace isnt grounded properly. Check the grounding !!!
  2. Replies
    2
    Views
    531

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  3. [QUOTE=jpsmith1cm;15440951]There are two...

    [QUOTE=jpsmith1cm;15440951]There are two questions being asked here with three possible answers.

    #1. Are we trying to determine exactly how much refrigerant is contained in the system? This...
  4. Replies
    11
    Views
    1,541

    Yes, my company uses the Callahan roach pring...

    Yes, my company uses the Callahan roach pring which we uploaded into our ESC software. No complaints. 100% paperless.
  5. Replies
    16
    Views
    1,187

    Or you could just check the amp draw of the...

    Or you could just check the amp draw of the aux/emer heat....
  6. Replies
    8
    Views
    1,064

    Sctech is right on the money. Check all wiring in...

    Sctech is right on the money. Check all wiring in the Heatpump, I just last week chased down a low voltage short and it was a low pressure switch wire rubbing on copper. Problem solved. Check and...
  7. Check unit for proper gas pressure, furnace will...

    Check unit for proper gas pressure, furnace will tell you the minimum gas pressure required for the furnace. But like the other guys said, check air flow, flame sensor & check to see if you have...
  8. Replies
    30
    Views
    2,796

    I myself am relatively new in this field 3+...

    I myself am relatively new in this field 3+ years. I am currently running all the service for my company. My boss always tells me if you can't figure something out and your in a bind to call tech...
  9. Replies
    28
    Views
    2,172

    What you have is a unit that when it was...

    What you have is a unit that when it was manufactured the fan motor used a run cap. That is continuously energized. Then the motor went bad and someone installed an aftermarket motor that uses a...
  10. Replies
    2
    Views
    567

    R-22 has tripled in the last 2 months in my area....

    R-22 has tripled in the last 2 months in my area. That being said I believe the customer should be informed of this when considering repairing an aging 22 system. I just sold a new system today...