    Here's s couple of quick pics I was able to grab...

    Here's s couple of quick pics I was able to grab before I got busy the day of posting.
  2. I understand this. But at the time I took these...

    I understand this. But at the time I took these classes I assure you, they taught this and did not teach that it is a result of moisture but of mixing the oils. I knew better because I'd read that...
  3. I know exactly what your referring to Jdbradley:...

    I know exactly what your referring to Jdbradley: I was told this during school as well as several classes that I took years ago when 410a was coming on the scene. I always heard of it as "green...
  4. Replies
    34
    Views
    3,291

    Yes sir fellas. It is the tech pac backpack.

    Yes sir fellas. It is the tech pac backpack.
  5. To my understandings per a Rheem tech, many of...

    To my understandings per a Rheem tech, many of the older R22 systems did come with compressors with mineral oil and if you were to retrofit a new 410A system in, you would need to flush the lineset...
  6. Replies
    34
    Views
    3,291

    Received my Veto Pro bag

    Like a couple of you fellas I've been waiting on this bag to replace the Lowes brand bag I've replaced 3x.

    I have to say that although the bag seems pretty well designed and built, it's a beast! ...
  7. Name of part number for manifold-less vacumm measuring..

    Hi all. I tried to searching, but found not answer. I'm trying to get double down on my near-perfect vacuums on systems and I've read there was a setup for pulling a vacuum on a system without using...
  8. Replies
    48
    Views
    2,301

    It's a conspiracy.

    It's a conspiracy.
  9. Replies
    7
    Views
    443

    While it might not be an issue for you, I got...

    While it might not be an issue for you, I got tired a couple of years ago of coming behind our installers (as well as a few jobs I had done when I was younger) and finding leaking joints everywhere....
  10. Replies
    24
    Views
    1,268

    I can't tell from the pics but last week I ran...

    I can't tell from the pics but last week I ran into for the second time, a similar situation exactly like the one your having. Someone had hooked up the primary drain to the secondary drain on the...
  11. Isolationism lol. And Pete your correct, he was a...

    Isolationism lol. And Pete your correct, he was a rep. I'm anxious to see how his homeschooling curriculum turns out.
  12. Perestroika was a front. Former KGB that...

    Perestroika was a front.

    Former KGB that defected, told his story and what we Americans would be facing.
    http://youtu.be/R3nXvScRazg
  13. Replies
    11
    Views
    476

    After years of taking pride in my tan and toned...

    After years of taking pride in my tan and toned self, I've finally wized up and started using it every day.
  14. Replies
    26
    Views
    2,283

    I think your refering to the normal liquid valve,...

    I think your refering to the normal liquid valve, no? Where you attach your "red hose" to the tap to measure head/high pressure? If so, then yes they are all still standard, as it was on the system I...
  15. Replies
    26
    Views
    2,283

    Thanks for the reply brother. I checked several...

    Thanks for the reply brother. I checked several places with the my clamp-style temp meter across various sections of the liquid line including the drier and it was all kosher.

    I was really tempted...
  16. Replies
    8
    Views
    582

    Smartphone bluetooth headphones?

    Do any of you use a set of these? I use my phone and make calls through the day. These iPhone earbuds aren't cutting it anymore and am looking for a wireless set that both stays out of the way (like...
  17. Replies
    26
    Views
    2,283

    caveman: I actually suspect that is has been...

    caveman: I actually suspect that is has been possibly causing a problem with a couple of systems. Glad you mentioned this.
  18. Replies
    26
    Views
    2,283

    I've done it once too. I'd been servicing Rheem...

    I've done it once too. I'd been servicing Rheem R22 systems all day and my last call was on another Rheem the same color, size and shape of the others and appeared equally as old and I failed to...
  19. Replies
    26
    Views
    2,283

    Thanks fella for the help. During the pump down...

    Thanks fella for the help. During the pump down the compressor did seem to have a more difficult time coming down on the liquid side. I did check the blower speed and it was the highest it could go....
  20. Replies
    26
    Views
    2,283

    Advice on tshooting this 3 ton split.

    Went to a service call for a customer that our company has been doing maintenance on yearly since we installed it. Unit is a 2004, 3 ton split with piston on a horizontal furnace. Last year the owner...
  21. Replies
    53
    Views
    6,051

    As I'm not too familiar with various batteries,...

    As I'm not too familiar with various batteries, can you possibly suggest the best place to purchase the eneloops from and do you purchase your chargers from them or elsewhere?
  22. Replies
    53
    Views
    6,051

    Thanks Brian for the quick response. I still have...

    Thanks Brian for the quick response. I still have faith in their products, probably just a fluke. I shouldn't have said "contact info" but phone number. I highly detest having to go through email and...
  23. Replies
    53
    Views
    6,051

    Thanks fellas for all the replies. I've been...

    Thanks fellas for all the replies. I've been meaning to write this post for sometime but I've been blessed with more work than usual.

    I recieved my Zebra light about a week ago. I don't have the...
  24. I learned this probably 6-7 years ago. :grin2: I...

    I learned this probably 6-7 years ago. :grin2: I believe the majority of my question was answered by keeping a hard start kit with me although I did find last week that with the Testo557s, I could...
  25. Well seasoned at this particular procedure....

    Well seasoned at this particular procedure. Breaking vacuums with liquid, charging via liquid through the kingv I guess what I should have asked in addition to the questioned that was answered by...