Search:

Type: Posts; User: captain123

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thanks for the info on the choke coil!

    Thanks for the info on the choke coil!
  2. Replies
    6
    Views
    769

    What is this post doing here?

    What is this post doing here?
  3. Replies
    10
    Views
    498

    It's about time for Army to beat Navy

    It's about time for Army to beat Navy
  4. Replies
    10
    Views
    498

    That was kind of what I was trying to say. It's...

    That was kind of what I was trying to say. It's good experience.
  5. Replies
    10
    Views
    498

    You're right.

    You're right.
  6. Replies
    10
    Views
    498

    We are supposed to be technicians, repairmen, you...

    We are supposed to be technicians, repairmen, you know we are supposed to fix stuff that doesn't work. There may not be any money to be made fixing a residential freezer but there can be a sense of...
  7. Replies
    73
    Views
    10,141

    Amen brother!

    Amen brother!
  8. Replies
    11
    Views
    1,250

    You need to know the BTU's of each appliance, how...

    You need to know the BTU's of each appliance, how many elbows and the length of the pipes.
  9. Replies
    73
    Views
    10,141

    It all depends on your attitude and how much you...

    It all depends on your attitude and how much you want to succeed. First you must have a mechanical apptitude if you do then you can make it. I am 64 years old, sold my company and went to work as...
  10. Replies
    13
    Views
    1,194

    Apparently, Rheem likes more superheat than you...

    Apparently, Rheem likes more superheat than you do, but I have to agree it seems odd.
  11. Replies
    6
    Views
    769

    Thanks, this was a great help.

    Thanks, this was a great help.
  12. Replies
    6
    Views
    769

    Carrier condenser info

    Does anyone have website info where I can get data, such as sub-cooling, & superheat requirements and where to measure the temps on a Carrier 38-AH-104---601?
  13. Thread: Manly help

    by captain123
    Replies
    8
    Views
    827

    So where is the gym. Do they have any Spin...

    So where is the gym. Do they have any Spin classes? I'll come over and check it out.
  14. I've put in a lot of Manureop compressors in...

    I've put in a lot of Manureop compressors in Tranes, never had a problem. You can braze in a Copeland and it will also cool fine, you may not get 10 or 20 years out of it but the customer will feel...
  15. Replies
    15
    Views
    1,705

    There is one thing no one is telling you. ...

    There is one thing no one is telling you. There's a button right behind the transmogifer; hold it down for 3 seconds and it will reset the unit back to factory default settings and you will be good...
  16. Replies
    15
    Views
    1,705

    There are so many different things that could be...

    There are so many different things that could be wrong it is just impossible to make a good quess with out having the unit in front of us. Having said that, one guess is the compressor has tight...
  17. Replies
    15
    Views
    1,705

    I agree!

    I agree!
  18. Replies
    14
    Views
    665

    No worries.

    No worries.
  19. And installed by a licensed electrician, a permit...

    And installed by a licensed electrician, a permit pulled and an inspection.
  20. The specs were probably written in China. The...

    The specs were probably written in China. The unit probably requires a 15 amp circuit which would require a #14 copper wire. You can buy 14/3 with ground from a local home center. 14/3 would have...
  21. Replies
    15
    Views
    1,387

    What brand and size equip? How did you determine...

    What brand and size equip? How did you determine that it is running in the proper direction?
  22. Three phase compressors don't have common, run or...

    Three phase compressors don't have common, run or start windings, each winding has the same resistance, that's why the ohm readings should all be about the same and that's why there's no run or start...
  23. Replies
    6
    Views
    1,305

    I agree, use a timer.

    I agree, use a timer.
  24. Thread: delay timer

    by captain123
    Replies
    14
    Views
    1,609

    An example of a delay on break relay would be: ...

    An example of a delay on break relay would be: some residential air handlers have a relay to keep the blower motor running for appoximatly 90 seconds after the thermostat is satisfied. The delay...
  25. Replies
    31
    Views
    2,686

    I watched the pressures during an off cycle and...

    I watched the pressures during an off cycle and they did not move until there was a call for cooling. It's been 3 days now and no tripping. We'll see what this weekend brings, the unit is on a...
Results 1 to 25 of 88
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event