Type: Posts; User: gone404

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Nice linesets

    by gone404
    Replies
    9
    Views
    2,700

    The units were dragged over there to do the...

    The units were dragged over there to do the landscaping... No electricals and note the unistrut to the left. Sorry for the buzzkill. :-)
  2. Replies
    9
    Views
    2,461

    That dirty PVC brings down the whole job guy... ...

    That dirty PVC brings down the whole job guy... I used to chuck garbage like that right back in the bin. If thats all you could get, pipe the stuff in the rafters with the dirty stuff and bring a...
  3. Thread: Supersized!

    by gone404
    Replies
    12
    Views
    2,654

    No guards, locked room, strict access... unit...

    No guards, locked room, strict access... unit was running at about 30% when this was taken, flash froze motion of wheel and belts. When it is at full howl we don't enter room, can't get door open!
    ...
  4. Thread: Supersized!

    by gone404
    Replies
    12
    Views
    2,654

    Current motor is 30hp on a VFD, dead motor (out...

    Current motor is 30hp on a VFD, dead motor (out of view on floor) was 50hp, dates on the wall say motor was swapped in 77. They probly did'nt remove it because it must weigh 500lbs! The open drive is...
  5. Thread: Supersized!

    by gone404
    Replies
    12
    Views
    2,654

    Not really a Wall of Pride deal but wanted to get...

    Not really a Wall of Pride deal but wanted to get comments on the biggest dang blower I've ever worked on... Paul is 5'-9" for the size comparison. I went commercial because "it all works the same,...
  6. Replies
    13
    Views
    4,467

    Yep, all the time... Block them wide open and...

    Yep, all the time... Block them wide open and leave them in place. I'll try to get a pict of the biggest one I've seen.
  7. Thread: megging

    by gone404
    Replies
    29
    Views
    3,934

    And, megging the motor and wire run when...

    And, megging the motor and wire run when installing a new or replacement drive is a crucial step... I've never personally paid for a new motor or drive and plan on keeping it that way!
  8. Replies
    4
    Views
    839

    LMAO... I can bungle my way through most any...

    LMAO...

    I can bungle my way through most any minor JC issue... In my region that makes me an ACE!
  9. Thread: motor problems

    by gone404
    Replies
    8
    Views
    773

    Does it start.run.trip or go straight to trip?...

    Does it start.run.trip or go straight to trip? Check each leg to ground, does shaft turn? Any smoke, odor, sparks, fire?
  10. Thread: Cleaver Brooks

    by gone404
    Replies
    26
    Views
    1,547

    Re: your profile ...

    I've heard a KaWHAMMMM or two.... I usually don't hang around past the Ka!

    :-)
  11. Replies
    19
    Views
    1,498

    Purging very seldom per light, I think machine is...

    Purging very seldom per light, I think machine is very tight. I know certain operating conditions can drive up non-condensables but I'm not seeing that. Yes, big boss can't be talked to! I asked for...
  12. Replies
    19
    Views
    1,498

    OK, Pump screens and tower strainer getting done...

    OK, Pump screens and tower strainer getting done by this time next week (I'm in the middle of changovers). I'll check delta P across absorber and monitor the inlet steam to see if it is still...
  13. Replies
    19
    Views
    1,498

    Here is a copy/ paste of the unit running: You...

    Here is a copy/ paste of the unit running:
    You can see, no load in the bldg, unit has run since about noon, on days like today it may lock out 10 times or not at all. Unit not reaching setpoint,...
  14. Replies
    19
    Views
    1,498

    Re: Low refrigerant water trip?

    Hi Randy!

    I'll get the steam where it should be and then recheck the cyclegard. My diagram shows a pilot lamp to show when the cyclegard is open but my machine does not have it. I'm positive I'm...
  15. Replies
    19
    Views
    1,498

    OK, cool, I understand the load thing... scary...

    OK, cool, I understand the load thing... scary part is that the steam pressure drops to as low as 3# during operation. This is due to problems on the transmission end. As a side note, we fired up the...
  16. Replies
    16
    Views
    3,807

    LMFAO! My vote for winner! This under a beach...

    LMFAO! My vote for winner!

    This under a beach house?
  17. Replies
    19
    Views
    1,498

    No VFD on Cond pump. VFD on Tower fan per cond....

    No VFD on Cond pump. VFD on Tower fan per cond. return to absorber setpoint of 80 deg. Was spot on today. Would I benefit from lower SP?

    Only valves on setup are 2-way for free cooling off plate...
  18. Replies
    18
    Views
    1,767

    NP, glad I could help.

    NP, glad I could help.
  19. Thread: Doooozy!

    by gone404
    Replies
    0
    Views
    2,068

    Boss sent me to the private home of a facilities...

    Boss sent me to the private home of a facilities manager for one of my accounts today... said only "he has boiler problems". I arrive to find a steam boiler on a two-pipe steam system now trying to...
  20. Thread: Screening

    by gone404
    Replies
    1
    Views
    677

    Have the owner take it up with the code...

    Have the owner take it up with the code authority... Aint your fight, you are just the messenger.
  21. Replies
    18
    Views
    1,767

    I would start here: ...

    I would start here:

    http://www.commercial.carrier.com/commercial/hvac/general/0,2047,CLI1_DIV12_ETI1876_MID4390,00.html
  22. Replies
    19
    Views
    1,498

    Re: Few questions!!!

    Went out today on a different problem and was able to run the Absorber and take measurements:

    Run time +/- 30 mins OAT 67deg. F

    Steam varied between 3-6 psi, not sure why as steam valve was...
  23. Replies
    16
    Views
    3,807

    We can have a quote contest... "Customer said...

    We can have a quote contest...

    "Customer said he wanted water cooled condensers..."
  24. Replies
    16
    Views
    3,807

    We've got to have more details on this rig!

    We've got to have more details on this rig!
  25. Replies
    5
    Views
    612

    Switches good, tower good... Yes, I've been...

    Switches good, tower good...

    Yes, I've been reading up on Absrbrtek... hoped he would post a reply to my questions!
Results 1 to 25 of 79