Search:

Type: Posts; User: emcontrols

Page 1 of 11 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    6
    Views
    1,081

    Yep got a new screw on cap and bracket, trane did...

    Yep got a new screw on cap and bracket, trane did still have that, I just liked the upgraded sump and cover better, Im also gonna move the eductors to the old sump, add a refrigerant cooled oil...
  2. Replies
    6
    Views
    1,081

    No performing a conversion and would have like to...

    No performing a conversion and would have like to put the oil sump with the sump cover that has the screw on filter and oil sampling port, but since Trane no longer makes the sump its getting an...
  3. Not near as long as it would take to gather the...

    Not near as long as it would take to gather the endless amounts of data you are talking about and attempt to be accurate on a per application basis, there are already data histories being gathered...
  4. If the MODE (Heat or Cool) is true, start a...

    If the MODE (Heat or Cool) is true, start a timer. If the space temp is greater than or equal to the space temp plus 1 Deg F, stop the timer and then you know how long it took to raise the space temp...
  5. Replies
    8
    Views
    791

    1. No you must use IPLV, call the factory for...

    1. No you must use IPLV, call the factory for this number if not in literature they can tell you.
    2. Design WB of tower not actual
    3. Design KW at nominal full load not actual, If 2 identical...
  6. Replies
    6
    Views
    1,081

    That works. Thank you

    That works. Thank you
  7. Replies
    6
    Views
    1,081

    Looking For Trane CVHE/CVHF Oil Tank

    Trying to find a new or used Trane CVHE/CVHF Oil Tank (Sump) with the integrated oil filter style (Cover) Factory says obsolete. NOT the latest style with refrigerant pump and sets on the ground but...
  8. Replies
    26
    Views
    7,235

    Just throwing some input in to the mix!!! First...

    Just throwing some input in to the mix!!! First off that would be a huge plus to be able to access technical info on all makes and models that were archived (Library) with OEM support that was not...
  9. Just my 2 cents worth. 1. You are one of the...

    Just my 2 cents worth.

    1. You are one of the first in and the absolute last out on any project weather it be new construction, retro, reno, two years, two weeks, world class museum or doc in the...
  10. Thread: Distech

    by emcontrols
    Replies
    14
    Views
    3,718

    Wow, Ive been through alot in the last few days,...

    Wow, Ive been through alot in the last few days, Ok I got past the win 7/64 home version and the lon stick, everything was fine until I attached a ecsmartvue to the subnet of the ecl610, now my lon...
  11. Thread: Distech

    by emcontrols
    Replies
    14
    Views
    3,718

    where do I confirm that AX is set to look at port...

    where do I confirm that AX is set to look at port 1, the adapter is plugged in to port one. Also do I need to load a distech driver for adapter or is the echelon driver sufficient?
  12. Thread: Distech

    by emcontrols
    Replies
    14
    Views
    3,718

    Ok, received adapter installed driver etc and...

    Ok, received adapter installed driver etc and confirmed, created a station with a bcplonetwork, added wizards in to config/services Now how do I make it recognize lon adapter. ECL600 powered and...
  13. Thread: Distech

    by emcontrols
    Replies
    14
    Views
    3,718

    Thank you, I will have the lon adapter quick...

    Thank you, I will have the lon adapter quick shipped to me tomorrow and keep you posted. Unfortunately on this project we put the cart with no wheels before the horse with no legs, so Im learning on...
  14. Thread: Distech

    by emcontrols
    Replies
    14
    Views
    3,718

    Ok, So with a LON adapter and driver on laptop...

    Ok, So with a LON adapter and driver on laptop with AX direct to ECL610 I can program without the need for a JACE or EC BOS?
  15. Thread: Distech

    by emcontrols
    Replies
    14
    Views
    3,718

    Well, thats the problem Im having, Not sure what...

    Well, thats the problem Im having, Not sure what to connect with, stereo/mono to USB, LON bus or what. Or Do I have to have the EC-BOS.

    2nd question will the controller run stand alone after...
  16. Thread: Distech

    by emcontrols
    Replies
    14
    Views
    3,718

    Distech

    New to Distech, I have EC net AX pro running on laptop. Question I have is can I program an ECL610X direct connected to laptop, or do I have to have an EC-bos?
  17. Replies
    83
    Views
    12,258

    I also want to extend my strong appreciation of...

    I also want to extend my strong appreciation of the lockhart team, not only is it the best digital gauges (AK900) I have purchased, but the most accurate, which is extremely important. Im only as...
  18. Yep, use the reheat coil when humidity gets above...

    Yep, use the reheat coil when humidity gets above determined hum setpoint, and have the DDC loop use the same reset setpoint as your cooling coil is simultaneously until humidity drops then can the...
  19. Replies
    4
    Views
    1,092

    What specifically are we trying to control or are...

    What specifically are we trying to control or are you needing fundamental control of various systems. It also depends on the type of cooling medium IE Amonia, Refrigerant, CO2 and etc... What system...
  20. Yes, I do beleive that was the name of the pipe,...

    Yes, I do beleive that was the name of the pipe, couldnt remember the name, Is it flexible like pex, He called it george pex. I'll find out for sure tommorrow.

    On the store employee thing getting...
  21. Well in short my last word of nothingness is you...

    Well in short my last word of nothingness is you are definately not the norm. To have a management staff that is refer educated is not only rare but slim to none, now dont get me wrong all the stores...
  22. Not getting in the middle of things but I do have...

    Not getting in the middle of things but I do have a legit question. Im always interested in analytical stuff, How about product loss %. has it went up or down. and profit? Dont need numbers just...
  23. I asked the exact same question and the answer...

    I asked the exact same question and the answer was NO, It was to the cases. Ill Do some more interrigation and post some facts next week.
  24. Yes like plumbing water plastic, pretty good...

    Yes like plumbing water plastic, pretty good stuff for plumbing, definately dont think it would be good for CO2.
  25. I know of at least 4 supermarkets this summer...

    I know of at least 4 supermarkets this summer that will be getting the CO2 systems Im referring to. And I was wrong its 4x4x4. CO2 in pex to cases, dont have alot of details but as I get more info...
  26. We need to pray for the over engineering...

    We need to pray for the over engineering engineers to do their job, and this will keep us all on our toes(job security). Staying up with the latest technologies and becoming heavily involved with the...
  27. Replies
    558
    Views
    69,583

    Yes monitored the bar graph, when TXV,s were on...

    Yes monitored the bar graph, when TXV,s were on target very small incremental changes to plus/neg pressures when it was hunting you could see the bar graph swing pretty far out. Going to troubleshoot...
  28. Replies
    558
    Views
    69,583

    Finally got mine and set superheat and confirmed...

    Finally got mine and set superheat and confirmed ref charge using subcooling on a R-22 air cooled chiller yesterday. And superheat on a R-404a dual temp coffin case today. Super impressed with the...
  29. Replies
    17
    Views
    2,387

    Sure would be nice to have some pics, have you...

    Sure would be nice to have some pics, have you pulled a oil sample and sent in for testing??????:grin2:
  30. Replies
    4
    Views
    1,459

    The schedule is just toggling a binary variable...

    The schedule is just toggling a binary variable which enables the VAV ucm controllers to go in to calibration mode, once enabled the VAV ucm does the rest, therefore no need to keep the scheduled...
  31. Replies
    6
    Views
    910

    Usually on OA temp routines i set the execution...

    Usually on OA temp routines i set the execution time every 30 minutes to eliminate fluctuations. This simplifies the programing. Just a thought!
  32. Replies
    6
    Views
    910

    I agree with Will, that first routine doesn't...

    I agree with Will, that first routine doesn't make sense at all, I would confirm if that routine is even enabled to run! second routine works, but I prefer to use a DDC loop to control staging. Ditto...
  33. Replies
    30
    Views
    3,599

    Is this a new start-up or existing application,...

    Is this a new start-up or existing application, Im sure you have checked the obvious like rotation and all your iso valves are open. What is amp draw at fault versus nameplate etc... need more info,...
  34. Replies
    558
    Views
    69,583

    Yep mine is stuck in san fran too, girlfriend...

    Yep mine is stuck in san fran too, girlfriend ordered on the 17th. But I know it will be worth the wait. It will be my first set, Im ready to go play.:grin2:
  35. Does the piping resemble this if so put DP where...

    Does the piping resemble this if so put DP where shown.
  36. Dont know if this applies to the application, but...

    Dont know if this applies to the application, but typically the purpose of the diff press sensor is to be located at the absolute farthest pipe run with a load on it. And its setpoint is to be what...
  37. Replies
    16
    Views
    1,600

    I agree with JP, D makes since. Ive been locked...

    I agree with JP, D makes since. Ive been locked in a walk in with the inside door release and could not with every once of strength open the door right after a defrost cycle. That walk in was tight I...
  38. Replies
    16
    Views
    3,925

    Wonder what happens when lightning strikes or...

    Wonder what happens when lightning strikes or better yet a internal winding short to ground. Holy moly that should be illegal.
  39. Replies
    3
    Views
    1,081

    What company or corporation are you with? Most...

    What company or corporation are you with? Most have a product support manual! If not it needs to be old school, measure dimensions and call a custom gasket building company.
  40. Not impressed with the 450 series, 350 series im...

    Not impressed with the 450 series, 350 series im a believer.
  41. Ok, I understand the concept of creating a time...

    Ok, I understand the concept of creating a time lag to assist in mixing the return water from the return lines. Wow thats a tough question, there are an endless amount of variables that need to be...
  42. Replies
    11
    Views
    1,927

    Throw an amp probe on circuit and record then...

    Throw an amp probe on circuit and record then tighten all associated screw terminals and record, oh yea dont forget to check tightness of solenoid coils especially if their compound compressors....
  43. Maybe im confused but i couldnt resist...

    Maybe im confused but i couldnt resist responding, By not using ASME sealed tanks wont you lose your system pressure and then in return have to way oversize the pumps to compensate? And im still not...
  44. Replies
    31
    Views
    9,596

    Tons got to keep the door closed. Especially...

    Tons got to keep the door closed. Especially since you mentioned frost not ice. Frost indicates moisture infiltration in to the walk in. Fix the door problem after you completley remove any and all...
  45. Replies
    75
    Views
    5,678

    Here is one to chew on!http://asicontrols.com

    Here is one to chew on!http://asicontrols.com
  46. Agree with KLOVE and hope you have a generator in...

    Agree with KLOVE and hope you have a generator in the design to power pumps and AHU's on power fail or the chilled water storage investment really isnt gaining you anything for 10 minutes of down...
  47. Replies
    5
    Views
    763

    Its been a long time since I have done PCL but...

    Its been a long time since I have done PCL but here is a rough draft!!!
    *LO OATMP LT *40
    *L1 SPCTMP GT *80
    *L2 SPCTMP LT *64
    *L3 *LO OR *L1
    PUMPENAB *L2 OR *L3
    *ELSE
    PUMPENAB FALSE
    *IFT...
  48. Thread: Powerflame?

    by emcontrols
    Replies
    10
    Views
    2,035

    Did you set dip switches identical to old module...

    Did you set dip switches identical to old module you replaced????:whistle:
  49. Replies
    3
    Views
    1,705

    Ditto. With e-ware or tracer PCL edit front end...

    Ditto. With e-ware or tracer PCL edit front end software
  50. Replies
    3
    Views
    1,705

    go to trane website under commercial literature...

    go to trane website under commercial literature type in TUC and search. Should be a TUC IOM "page 38" has zone sensors.
Results 1 to 50 of 546
Page 1 of 11 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365