Search: Search took 0.03 seconds.

  1. Thread: MNB- 1000

    by controlgeek
    Replies
    2
    Views
    171

    Workplace tech

    Workplace tech
  2. Replies
    24
    Views
    1,776

    I would be interested in any feedback on the...

    I would be interested in any feedback on the vykonpro class. I missed it due to having back surgery but am still interedted if it is worth it?
  3. Replies
    12
    Views
    1,035

    I am planning on attending

    I am planning on attending
  4. Replies
    12
    Views
    614

    I doubt you will find a prn file. Those are...

    I doubt you will find a prn file. Those are created from Hvac Pro when saving a config if the option is selected.
  5. Check your email.

    Check your email.
  6. There is no email in your profile so I can't send...

    There is no email in your profile so I can't send you anything.
  7. Replies
    3
    Views
    329

    They didn't willing give it to me and we do...

    They didn't willing give it to me and we do Distech also. I helped myself.
  8. Replies
    3
    Views
    329

    As far as I know it is an internal Distech...

    As far as I know it is an internal Distech Controls module created by Distech. It brand checks for Distech. I have it from some Distech stations created by Distech for some National Accounts.
  9. Replies
    2
    Views
    311

    User defined names do not download. If I recall...

    User defined names do not download. If I recall correctly Q/A assigned names are there when uploaded because it knows the application selected. Both ASC's and the DX have not much RAM so names were...
  10. Replies
    7
    Views
    622

    http://hvac-talk.com/vbb/showthread.php?1877411-HV...

    http://hvac-talk.com/vbb/showthread.php?1877411-HVACPRO-8-08B-Patch&highlight=hvacpro
  11. Replies
    7
    Views
    622

    You have to enter commissioning mode to see live...

    You have to enter commissioning mode to see live data. The ****** will be replaced with the live data when in commissioning mode. The offset goes on the input. If I recall you just double click to...
  12. Replies
    10
    Views
    562

    What error message is there when LON2 fails to...

    What error message is there when LON2 fails to start?
  13. Replies
    2
    Views
    324

    I use VM workstation with multiple VM's of...

    I use VM workstation with multiple VM's of different OS versions and software to keep things separate when needed or on a particular OS when needed.
  14. Replies
    16
    Views
    2,001

    http://www.circon.com/about-us/contact-us/

    http://www.circon.com/about-us/contact-us/
  15. http://veronics.com/products/infrared_gas_sensing/...

    http://veronics.com/products/infrared_gas_sensing/Vaporstat9002.pdf
  16. Replies
    10
    Views
    881

    You need to be certified in N4. If you are Ax...

    You need to be certified in N4. If you are Ax certified there is an elearning module from Tridium that gives you N4 certification. You don't have to take the 5 day class.
  17. Replies
    16
    Views
    2,001

    There is another download for the wizards. The...

    There is another download for the wizards. The instructions I had from a few years ago for their FTP no longer work so I would suggest contacting Frazier.
  18. Replies
    13
    Views
    760

    It seems the boiler enables should not be staged...

    It seems the boiler enables should not be staged like that. If a sequencer is desired I would look at a PID loop that drives boiler enables from loop delta T, average valve position perhaps OAT for...
  19. Replies
    13
    Views
    760

    make the prop band number larger. In a DX a...

    make the prop band number larger. In a DX a negative prop is reverse acting. Try .5 for integral.
  20. Replies
    13
    Views
    900

    That is not what Distech Tech support said but I...

    That is not what Distech Tech support said but I didn't push the issue with them.
  21. Replies
    13
    Views
    900

    No. There is nothing special about the...

    No. There is nothing special about the distech.license that comes in a Distech branded JACE. It has the same information as in a standard Tridium license. The only restriction I am aware of is if you...
  22. Replies
    13
    Views
    900

    I only ran into it once. Some points would come...

    I only ran into it once. Some points would come into the JACE and stay in fault. Distech tech support said it needed to be a BCP network and it fixed it but I was skepitcal because I have thought the...
  23. Replies
    5
    Views
    613

    Talk to Distech. My Distech updated automatically...

    Talk to Distech. My Distech updated automatically to the new license.
  24. Replies
    13
    Views
    900

    Shouldn't affect anything. It is adding Distech...

    Shouldn't affect anything. It is adding Distech files to the JACE. If you rename *.dist to *.zip you can open and see what will be installed. Usually it is just the Distech modules for BCP and libs...
  25. Replies
    13
    Views
    900

    Need to use bcp network and load dist file in...

    Need to use bcp network and load dist file in jace. Ran into this trying to replace an 8 bit distech card with a 32 bit in a lynxspring jace.
  26. Replies
    7
    Views
    599

    Apparently you can stop a Trane :P

    Apparently you can stop a Trane :P
  27. Replies
    8
    Views
    893

    Don't know if you can anymore. I have had R2 for...

    Don't know if you can anymore. I have had R2 for a long time. I would talk to your distribution channel.
  28. Replies
    8
    Views
    893

    Don't know about the open tool but my R2 license...

    Don't know about the open tool but my R2 license was updated to expire in 2030 now instead of annually.
  29. Replies
    13
    Views
    912

    Viconics

    Viconics
  30. Replies
    41
    Views
    2,310

    18 months included with every license (additional...

    18 months included with every license (additional years can also be purchased upfront)
    • Gap charges apply if SMA purchases after expiration (5 year max)
    • All update builds, patches and upgrades...
  31. Replies
    41
    Views
    2,310

    yes, it varies by supervisor based on part number...

    yes, it varies by supervisor based on part number and on JACE's. I presume the costing will vary somewhat by distribution channel but can't talk pricing here if I recall correctly.
  32. Replies
    41
    Views
    2,310

    MAINTENANCE Q: Is maintenance mandatory? Will...

    MAINTENANCE
    Q: Is maintenance mandatory? Will this be a mandatory
    recurring cost for customers?
    A: Software Maintenance Agreements (SMAs) are
    mandatory for the first year (18 months are included,...
  33. Replies
    3
    Views
    503

    You can either use KMC bacstage software or the...

    You can either use KMC bacstage software or the KMC Niagara module(s) to view and modify logic.
  34. Have to have a server to communicate through to a...

    Have to have a server to communicate through to a EC-GFX controller for programming. Distech uses a JACE (or a station on a laptop) or Lonwatcher from the LNS side. If you have Ax installed you can...
  35. Replies
    11
    Views
    1,413

    The non isolated COMM3 is 1200 Baud 8N1 with no...

    The non isolated COMM3 is 1200 Baud 8N1 with no flow control. Not sure if Isolated is the same.
  36. Replies
    3
    Views
    451

    No I don't. You could try the tridium default...

    No I don't. You could try the tridium default which is what Lynxspring uses I believe.
  37. Replies
    3
    Views
    451

    connect with the platform and ftp it out.

    connect with the platform and ftp it out.
  38. Replies
    5
    Views
    964

    Thanks very much

    Thanks very much
  39. Replies
    5
    Views
    964

    Ax Switcher

    Does anyone have the most current version of Ax Switcher written by Martin Tremblay they could share?
  40. Replies
    9
    Views
    690

    The UNC-520 was Invensys rebranded JACE-545. It...

    The UNC-520 was Invensys rebranded JACE-545. It would have talked via lon to the MNL-800. Without the old database or the workplace tech code you may have challenges determining points used since it...
  41. Replies
    3
    Views
    443

    Distech doesn't publish a list but the ones I am...

    Distech doesn't publish a list but the ones I am aware of:

    University Mechanical Contractors
    Cunningham Engineering
    Holaday Parks
    NCS Corp
    Macdonald Miller
    McKinstry

    I think some if not...
  42. Replies
    4
    Views
    582

    No driver that I am aware of for isolated comm3...

    No driver that I am aware of for isolated comm3 due to the hardware piece that is needed for the isolation. The two options I am aware of is to replace the isolated comm3 devices with new devices or...
  43. Replies
    5
    Views
    814

    EasyIO distributes it for free. They also have a...

    EasyIO distributes it for free. They also have a dropbox they will share with you to get updates literature etc.
  44. Replies
    4
    Views
    449

    You can run a station on your computer and drop a...

    You can run a station on your computer and drop a controller in from the Distech module and program offline. Need to have all the Distech stuff installed for the tools from smartinstaller.
  45. Please use the below link to dload. ...

    Please use the below link to dload.

    https://www.dropbox.com/s/700dd1df8x47roy/PcTool_5%20.zip?dl=0
  46. no email address in your profile to send it to.

    no email address in your profile to send it to.
  47. Replies
    18
    Views
    1,116

    Looks like a McQuay microtech board. There is a...

    Looks like a McQuay microtech board. There is a Tridium driver for it from around 3.4 or 3.5 Ax but I believe it uses the McQuay OPM panel to pass data to the units under it.
  48. I would contact the distributor where you...

    I would contact the distributor where you purchased your hpro from and get the 8.08B patch. Should be no charge.
  49. 630881

    630881
  50. I would suggest reinstalling the VM via the...

    I would suggest reinstalling the VM via the distribution file installer, perhaps it is corrupt or did not install properly. The dist file for it in 3.6 should be located at...
Results 1 to 50 of 522