Search:

Type: Posts; User: kevincompass

Page 1 of 5 1 2 3 4

Search: Search took 0.02 seconds.

  1. Thread: rmcc

    by kevincompass
    Replies
    6
    Views
    397

    Just make a. Site in ultra site and and down...

    Just make a. Site in ultra site and and down load the program in to it you need a 9 pin to 3 wire connector to pull program. And back it ip
  2. Replies
    1,150
    Views
    123,510

    Jim Bergmann be when will we be able to map...

    Jim Bergmann be when will we be able to map multiple temp sensors to one transducer . Seems like this is never going to happen would be a huge improvement.
  3. Replies
    2
    Views
    258

    Get a co2 leak detector

    Get a co2 leak detector
  4. Replies
    1,418
    Views
    225,460

    So I have benn bringing this up for a year. When...

    So I have benn bringing this up for a year. When are we going to do multiple superheats off one pressure sensor . Sporlan just released there new probes with this ability.
  5. Cut any case dryers out there nothing but a...

    Cut any case dryers out there nothing but a nuisance . I would much rather clean a strainer thin cut out a dryer . if thease are vapor injested scrolls check supcooler operation . also check rack...
  6. You should not need a false load and a...

    You should not need a false load and a desuperheater get your case superheats set . get your suction pressure staging under control you will be fine. Every one of the compressors need ice on the end...
  7. 62 psi is a pretty high float pressure are all...

    62 psi is a pretty high float pressure are all your compressors running when the rack is at 54 psi? Also if you have an e2 controler your float case is allways at 100% on CDs valve
  8. Garbage can and small sumpump works great

    Garbage can and small sumpump works great
  9. Replies
    1,418
    Views
    225,460

    Thanks for the reply Jim.I love the I connect...

    Thanks for the reply Jim.I love the I connect far out prefroms Sporlan or testo this would make it stand out even more
  10. Replies
    9
    Views
    675

    I do market work went and did HVAC for 2 months...

    I do market work went and did HVAC for 2 months was miserable and board every day came back to markets and never looked back . way more money in markets
  11. Replies
    1,418
    Views
    225,460

    Well the most important thing that this...

    Well the most important thing that this application is lacking is the ability to do several superheats off on transducer like 3 or 4 at once that's my biggest issue . also it would be nice if you...
  12. Replies
    1,418
    Views
    225,460

    Most residential company's and techs could give a...

    Most residential company's and techs could give a rat's ass about system performance and use there gages 6 months out of the year. Refrigation guys use the every day would love to see something more...
  13. Replies
    1,418
    Views
    225,460

    So is the I conect ever going to be able to do...

    So is the I conect ever going to be able to do several super heats off one transducer testo supposably will be able to on the next up date. Kinda seems like the iconect is coming more geared towards...
  14. Replies
    2
    Views
    320

    Pressure by pass valve to keep relif from poping...

    Pressure by pass valve to keep relif from poping off when head gets high it dumps to the suction
  15. Replies
    12
    Views
    1,755

    Pm me a price for the probes seprit from the I...

    Pm me a price for the probes seprit from the I conect and the whole package
  16. Replies
    1,418
    Views
    225,460

    What is the imperial doing for co2 seeing a lot...

    What is the imperial doing for co2 seeing a lot of co2 refrigeration . can the high pressure transducer handle it also is there a pt set up in the program .
  17. Replies
    6
    Views
    1,106

    Raise you sst float the sst you will keep this...

    Raise you sst float the sst you will keep this from happening.
  18. Replies
    1,418
    Views
    225,460

    So are we ever going to get the ability to do...

    So are we ever going to get the ability to do several superheats off one transducer. All this good but all the updates lately are geared to residential. Would like to see some more stuff for...
  19. Replies
    1,150
    Views
    123,510

    So how bout several superheats off one wire less...

    So how bout several superheats off one wire less probe been waiting for ever
  20. Thread: SORIT 12

    by kevincompass
    Replies
    8
    Views
    1,019

    I use this very set up for cds 9 and 7 valves ...

    I use this very set up for cds 9 and 7 valves works great
  21. Replies
    19
    Views
    2,109

    sump pump and a garbage can work good

    sump pump and a garbage can work good
  22. Replies
    19
    Views
    2,109

    Water nothing faster

    Water nothing faster
  23. Replies
    12
    Views
    1,024

    Leak lock is garbage I can't stand it when guys...

    Leak lock is garbage I can't stand it when guys put that stuff on equipment gets everywhere and is a pain to get apart nulog and teflon all the way.
  24. Replies
    1,150
    Views
    123,510

    So are we ever going to see multiple superheats...

    So are we ever going to see multiple superheats off one lp probe
  25. Replies
    6
    Views
    678

    Put a defrost clock on if your worried about oce...

    Put a defrost clock on if your worried about oce ups the way its set up causes it to run warm at times t stat is much better control
  26. Replies
    6
    Views
    678

    If it's a pump down system set the cut in below...

    If it's a pump down system set the cut in below the coldest ambient you will see many ci 20 co10
  27. Well I am sure it was over amping at 35/335 that...

    Well I am sure it was over amping at 35/335 that is high even with a warm box
  28. Replies
    1,150
    Views
    123,510

    K thanks Jim I do a lot of supermarket start ups...

    K thanks Jim I do a lot of supermarket start ups and this would cut down on start up time in a big way and I'm my opinion the only thing holding it back from being perfect
  29. Replies
    1,150
    Views
    123,510

    So how far off are we from several superheats off...

    So how far off are we from several superheats off one pressure sensor
  30. Replies
    12
    Views
    2,531

    What u want for the probes

    What u want for the probes
  31. Replies
    9
    Views
    1,267

    No need for a pencile heater that is not what the...

    No need for a pencile heater that is not what the OEM has designed just keep that drain clear and you be fine
  32. Replies
    9
    Views
    1,267

    They only have pan heaters with hot gas the coil...

    They only have pan heaters with hot gas the coil heater keeps it warm enough to drain out have you checked drip time or correct defrost times and termination many the drain was just plugged
  33. Replies
    1,150
    Views
    123,510

    Jim is there a way to see all the info from the...

    Jim is there a way to see all the info from the wireless sensors and from the 4 sensors on the I connect in one screen .If not this would be very hepfully for diagnostics. Also can you set up a...
  34. Check out parasence they offer all of this with...

    Check out parasence they offer all of this with remote mothering http://www.parasense.com/monitor.html
  35. Replies
    20
    Views
    3,840

    Looks good when are we going to get the ability...

    Looks good when are we going to get the ability to do multiple superheats off one transducer
  36. You can get them I have had to order one before...

    You can get them I have had to order one before its outrageously overpriced
  37. Replies
    7
    Views
    1,479

    Its more thin likely a baud rate issue change it...

    Its more thin likely a baud rate issue change it in device manager
  38. Replies
    15
    Views
    3,480

    Well now ur getting in to lieabity if ur repair...

    Well now ur getting in to lieabity if ur repair fails its on you if ur oem part has an issue it don't look as bad also most of these valves are factory welded with every big name mfg Sporlan is...
  39. Replies
    15
    Views
    3,480

    Nope never a fix just Cary spair orings its a hot...

    Nope never a fix just Cary spair orings its a hot cold issue causes gaskets to expand and contract
  40. Replies
    1,150
    Views
    123,510

    OK Jim do you have a lead time on the single...

    OK Jim do you have a lead time on the single sensor set up its prity much the last thin holding the I connect from being bullit prof .
  41. Replies
    1,150
    Views
    123,510

    Jim I updates this morning how do I use the...

    Jim I updates this morning how do I use the mautpule superheats / multiple compressor opperstion
  42. Replies
    1,150
    Views
    123,510

    Jim if this is the case if its a couple psi off...

    Jim if this is the case if its a couple psi off I would still like the ability to zero my probes all transducers eventually will read off
  43. Replies
    1,150
    Views
    123,510

    it was reading a vacuum at atmospheric pressure I...

    it was reading a vacuum at atmospheric pressure I tried to zero it when I went to the zero probe option it says there's pressure on probe remove pressure before zeroing probes and it wont let me zero...
  44. Replies
    1,150
    Views
    123,510

    imperial sent me a new probe I have to send the...

    imperial sent me a new probe I have to send the old one back I was just checking oil pressures and it just started reading off and was In a vaccume after that . I would really like to see the ability...
  45. Replies
    1,150
    Views
    123,510

    Has any one had wireless transducers fail I used...

    Has any one had wireless transducers fail I used my high side 2 times checking oil pressure and it stopped working just kept reading 10 hg also how can I read several superheats off one pressure like...
  46. Replies
    1,150
    Views
    123,510

    Jim I noticed the wireless transducers only go...

    Jim
    I noticed the wireless transducers only go down to 14 hg of a vaccume on the package will they be damaged if brought down lower thin that
  47. Replies
    1,150
    Views
    123,510

    Jim when will be able to do several superheats...

    Jim when will be able to do several superheats off one input and several temp sensors I just got my I connect I love it but when Iam starting up stores I may have to ajust 5 txvs at one time this...
  48. Replies
    1,150
    Views
    123,510

    Do we know a ship date yet

    Do we know a ship date yet
  49. Replies
    1,150
    Views
    123,510

    So are they going to ship on the 7th

    So are they going to ship on the 7th
  50. Replies
    1,150
    Views
    123,510

    Thanks for the reply Jim what about the sensor...

    Thanks for the reply Jim what about the sensor mapping for several superheats off one suction pressure
Results 1 to 50 of 224
Page 1 of 5 1 2 3 4