07-25-2012, 11:02 PM
Thread: R409a problems
by refertecbd- Replies
- 19
- Views
- 2,006
What is the size of the box and the Condensing...
What is the size of the box and the Condensing unit and Evap. Model number? Maybe the system is undersized for the size of the box. Just a thought.
-
07-19-2012, 07:58 PM
Thread: Oil cooler
by refertecbd- Replies
- 7
- Views
- 677
minimum oil temp allowed? Not really anything I...
minimum oil temp allowed? Not really anything I ever thought of usually with low temp R22 racks oil problems are related to oil getting TOO HOT and not to cold. What kind of problems are you having?
-
07-09-2012, 09:19 PM
Thread: Kysor Warren Single Deck Meat Case
by refertecbd- Replies
- 61
- Views
- 3,706
Off-time defrost is not recommended for M1A3...
Off-time defrost is not recommended for M1A3 cases.
From page 13 of the manual. I bet the reverse cycle fans have all be pulled out and replaced with standard 9 watt motors over the years and now... -
07-09-2012, 09:05 PM
Thread: Kysor Warren Single Deck Meat Case
by refertecbd- Replies
- 61
- Views
- 3,706
What is the method of defrost? 6 times a day...
What is the method of defrost? 6 times a day should be enough but 25 mins may not be long enough if its off cycle.
-
07-08-2012, 09:40 PM
Thread: Kysor/Warren anti sweat problems
by refertecbd- Replies
- 2
- Views
- 430
Thanks that has the info I was looking for.
Thanks that has the info I was looking for.
-
07-08-2012, 05:17 PM
Thread: Kysor/Warren anti sweat problems
by refertecbd- Replies
- 2
- Views
- 430
Kysor/Warren anti sweat problems
M#LV5H1-5U S#070543670 As I put in the title Anti-Sweat problems
The frame heaters are working but the door heaters are not. The plugs in the frame have no power to them.
Does anybody have a... -
05-17-2012, 07:53 PM
Thread: Freezer defrost wiring
by refertecbd- Replies
- 7
- Views
- 789
Without a model number or schematic of the box...
Without a model number or schematic of the box its hard to say, but I'd say no its not common. I don't think I ever seen a neutral broke as a factory wiring job. My guess would be someone was in...
-
04-24-2012, 05:49 PM
- Replies
- 4
- Views
- 737
Its been some years since I worked on the smaller...
Its been some years since I worked on the smaller cap tube systems but I always seen them plug in the first few inches after the drier
-
04-16-2012, 08:38 PM
Thread: Manitowoc GY404, Premature Harvest
by refertecbd- Replies
- 11
- Views
- 860
X2 They can get slimmed up and the work by...
X2 They can get slimmed up and the work by completing a circuit to groung to send a signal to the board to start harvest. Take it out clean it dry it off real good put it back in and if it still...
-
04-16-2012, 08:34 PM
Thread: What is this????
by refertecbd- Replies
- 14
- Views
- 795
Could it be a baseboard heat tstat?
Could it be a baseboard heat tstat?
-
04-11-2012, 11:14 PM
Thread: NEST T- STATS?
by refertecbd- Replies
- 36
- Views
- 2,723
http://www.controltrends.org/2011/12/see-the-new-n...
http://www.controltrends.org/2011/12/see-the-new-nest-programmable-thermostat-installation-in-atlanta/ Here's a link to web site call Controltrends has a 10 min video on the NEST. I think its...
-
04-11-2012, 10:04 PM
- Replies
- 7
- Views
- 546
Good stuff!! lol I guess now that the DIY'ers no...
Good stuff!! lol I guess now that the DIY'ers no how the change over the 410 the residential busy is gonna slow down....NOT
-
04-11-2012, 09:51 PM
- Replies
- 45
- Views
- 2,649
As soon as it warms up again its gonna freeze up...
As soon as it warms up again its gonna freeze up again!! 2.8 degrees of SH the system was not restricted. Change air filters clean Evap coil and verify that the blower is running full speed.
-
04-11-2012, 09:34 PM
- Replies
- 10
- Views
- 1,003
I'd say defrost termination also, its a 3 wire...
I'd say defrost termination also, its a 3 wire devise to terminate defrost then delay the fans from coming until the coil cools down some. I believe in a True box its a Flush mount style with a red,...
-
04-09-2012, 07:10 PM
Thread: 25y/o sub zero
by refertecbd- Replies
- 5
- Views
- 646
If you pulled the charge you should have tapped...
If you pulled the charge you should have tapped the high side. I see no mention of high side pressure or temp of liquid line without all the facts we are basically guessing and not troubleshooting. ...
-
04-04-2012, 08:36 PM
Thread: reach in drawer cooler
by refertecbd- Replies
- 4
- Views
- 579
Was the case at temp? Service call only for the...
Was the case at temp? Service call only for the water issue? The water may have come from the coil that was partly frozen, if the ice was sticking out past the drain pan. 32* does seem too cold of...
-
03-29-2012, 10:59 PM
Thread: market troubleshooting
by refertecbd- Replies
- 7
- Views
- 486
If it is a Rack system and on an E2 with temp...
If it is a Rack system and on an E2 with temp sensors there should be no reason the cases would be controlled with a Tstat, unless there is other cases on that Ckt with a colder SST?
-
03-28-2012, 05:48 PM
Thread: Display Cooler Issues
by refertecbd- Replies
- 4
- Views
- 488
12 psi with R404 = -26* SST TOO cold for dairy...
12 psi with R404 = -26* SST TOO cold for dairy cases. If its down again I suspect a leak you are missing. Its also possible that the contactor installed by plumber was not the correct part? This...
-
03-12-2012, 09:01 PM
Thread: Microchannel evap
by refertecbd- Replies
- 74
- Views
- 5,598
I've been seeing these come out on commercial...
I've been seeing these come out on commercial ref. condensing units. I haven't had any issues with them but I bet they'll be a pain to fix leaks on them.
-
03-07-2012, 03:57 PM
- Replies
- 57
- Views
- 4,866
CLC 1528 Large tool tote. I really like it I...
CLC 1528 Large tool tote. I really like it I carried the smaller one for years then got this one its only draw back is it can hold a lot of tools and get too heavy.
-
03-05-2012, 09:43 PM
Thread: Hoshisaki Issue
by refertecbd- Replies
- 19
- Views
- 1,019
Float switch is the input to the board to let it...
Float switch is the input to the board to let it know when the water level is up.
If it was a low water level the machine would just keep the water solenoid valve energized and not start anything... -
03-02-2012, 06:39 PM
Thread: Walk In Freezer Drain Heating Cable
by refertecbd- Replies
- 15
- Views
- 1,447
If no constant power I'd wire to N and 4 off the...
If no constant power I'd wire to N and 4 off the defrost clock so its on during ref. cycle which is most of the time.
-
02-27-2012, 10:25 PM
Thread: case fan spinning backward?
by refertecbd- Replies
- 19
- Views
- 831
I like that Chimp he makes money for me:cheers:
I like that Chimp he makes money for me:cheers:
-
02-27-2012, 10:10 PM
- Replies
- 20
- Views
- 1,385
:censored: YEA... Heard about that one sounds...
:censored: YEA... Heard about that one sounds like fun. I'm only about 30 miles from there so let me know if you need help:whistle:
-
02-27-2012, 10:07 PM
Thread: Manitowoc qy1894n3
by refertecbd- Replies
- 32
- Views
- 1,957
The bosses idea of pulling the charge is not bad...
The bosses idea of pulling the charge is not bad but I would weigh the gas you pull to verify if the charge is right.
Manitowocs will freeze good under charged by not harvest.