Search:

Type: Posts; User: redback

Page 1 of 2 1 2

Search: Search took 0.01 seconds; generated 30 minute(s) ago.

  1. Replies
    28
    Views
    1,199

    EASY-FLO flux, 550 to 800C mixes with water.

    EASY-FLO flux, 550 to 800C mixes with water.
  2. Replies
    28
    Views
    1,199

    556711556721 I'm currently working one that...

    556711556721

    I'm currently working one that has r600, the chinese weld where the steel tubing meets the copper in the high side leaked, i could not re weld it, i had to remove the old weld and...
  3. Replies
    51
    Views
    2,529

    Vibration loops :grin2:

    Vibration loops :grin2:
  4. Replies
    32
    Views
    1,411

    I did pull a digital manifold apart a while ago,...

    I did pull a digital manifold apart a while ago, pretty sure their was a varistor soldered to a washer under one of the pressure transducers, never checked much further, as i was checking a gas leak....
  5. Replies
    32
    Views
    1,411

    in post #5 i questioned what do you guys use for...

    in post #5 i questioned what do you guys use for high temps?

    If you use a thermistor that can measure discharge pipe temp when compressors have leaking valve plates reversing valves and and other...
  6. Replies
    32
    Views
    1,411

    You can't check SH when liquid refrigerant is...

    You can't check SH when liquid refrigerant is running through a manifold, because the refrigerant in the manifold effects gauge pressure and new liquid refrigerant entering a suction line effects...
  7. Replies
    7
    Views
    319

    with power tools of any sort, i only purchase...

    with power tools of any sort, i only purchase brand names that my local motor re-wind company is authorised to repair.
  8. Thread: Fluke 324.....

    by redback
    Replies
    3
    Views
    277

    Years ago i had a vs commodore 3.8 litre utility,...

    Years ago i had a vs commodore 3.8 litre utility, with a fibreglass canopy with ladder racks on top.

    One day after work i put a 1/4 - 3/8 drive socket on the roof between the fibreglass canopy and...
  9. Replies
    32
    Views
    1,411

    Thanks iceman With my fluke 902 when the meter...

    Thanks iceman

    With my fluke 902 when the meter is stable on a bench giving a temp reading of 22C and i pick the meter up the temp drops by a whopping 5.5C, meaning it can't meet rated spec...
  10. Replies
    32
    Views
    1,411

    What part?

    What part?
  11. Replies
    32
    Views
    1,411

    Can you list some of these sources

    Can you list some of these sources
  12. Replies
    32
    Views
    1,411

    Fujitsu use thermistors. What do you guys use...

    Fujitsu use thermistors.

    What do you guys use to measure high temps, and what specifically are you measuring that requires such high accuracy?
  13. Replies
    32
    Views
    1,411

    Well every day checks are out of the range of the...

    Well every day checks are out of the range of the thermistors on these new tools.

    For example a fujitsu A/C will slow the frequency down on a compressor if the discharge pipe temp gets to 120C,...
  14. Replies
    32
    Views
    1,411

    NTC thermistor vs thermocouple

    The new i manifold and yellow jacket service diagnostic tools use NTC thermistors, but thermocouples are better, so why are thermistors being used?
  15. Replies
    35
    Views
    2,747

    Some a/c units use higher value thermistors, for...

    Some a/c units use higher value thermistors, for example some of the Japanese branded reverse cycle a/c units, use outdoor pipe thermistors and inverter heat sink thermistors that can be 70k ohms at...
  16. Replies
    35
    Views
    2,747

    Amprobe is limited to 60k ohms resistance.

    Amprobe is limited to 60k ohms resistance.
  17. Replies
    27
    Views
    3,735

    The drain is undersized, has no fall, has no...

    The drain is undersized, has no fall, has no removable caps for maintenance cleaning.

    The cool room panelling needs chain supports for the weight of the ceiling.

    Their should be more than one...
  18. Replies
    39
    Views
    2,779

    Theirs heaps of them getting about, i have never...

    Theirs heaps of them getting about, i have never driven one though. Both my vehicles have small 2 litre capacity turbo diesel engines, they produce huge torque for a small engine.
  19. Replies
    39
    Views
    2,779

    I was at a wholesalers the other day picking up...

    I was at a wholesalers the other day picking up some copper and refrigerant gas, just sitting there with the sales guy, all of a sudden a white van turns up and a young scruffy head service tech from...
  20. Replies
    10
    Views
    648

    The first post was just a example. I wanted to...

    The first post was just a example. I wanted to know insurances and why customers are so bossy, my co-worker is not injured.

    My second post with the pics is real, i was just posting these pics to...
  21. Replies
    10
    Views
    648

    heres a photo i took. The customers fork truck...

    heres a photo i took.

    The customers fork truck driver lifted my fork cage into the air, then drove forwards, but the truck stopped as there was ice on the freezer floor, so the fork driver...
  22. Replies
    10
    Views
    648

    Customers and safety

    I have noticed in the hvac-r industry that some customers have this, you must do what a say attitude towards me as a service tech in regards to safety issues.


    From what i understand though is if...
  23. Replies
    16
    Views
    2,096

    What do companies such as veto pro pac and...

    What do companies such as veto pro pac and fieldpiece do with all these meters and bags returned for warranty, do they not seek new replacements from the chinese and thailand manufacturers?
  24. Thread: Metric 11in1?

    by redback
    Replies
    7
    Views
    715

    according to the klein USA website they are using...

    according to the klein USA website they are using nut drivers on their 11 in 1 that fit a 1/4 (6mm metric), 5/16 (8mm metric) and 3/8 (10mm metric) hex nut.


    However 1/4 is 6.35mm not 6mm, 5/16...
  25. Replies
    66
    Views
    8,146

    Ok so the DC MV reading will be fast on the...

    Ok so the DC MV reading will be fast on the Phoenix, because it doesn't have to auto range to measure DC MV, is it fast at fault finding a 300v DC circuit
  26. Replies
    66
    Views
    8,146

    So when the Phoenix meter is turned on does it...

    So when the Phoenix meter is turned on does it read 0v then auto range in either direction? the meters I have used when they turn on they usually auto rage from the lowest to highest on the dc volt...
  27. Replies
    66
    Views
    8,146

    It would slow down the meter on the d c volt...

    It would slow down the meter on the d c volt range to the point the meter would become annoying.
  28. What happened to the recovered refrigerant?

    What happened to the recovered refrigerant?
  29. Thread: Mooshimeter

    by redback
    Replies
    16
    Views
    1,411

    I'm pretty sure the fluke connect iPhone app,...

    I'm pretty sure the fluke connect iPhone app, allows insulation testers, fluke 289, fluke 3000fc and other meters to data log 10 at the same time to the iPhone.
  30. Replies
    66
    Views
    8,146

    490211I connot recommend fieldpiece clamps to...

    490211I connot recommend fieldpiece clamps to other co workers as they have a bare conductor receded by a mere 1mm, and i believe this can cause a short between two phases when checking current draw...
  31. Replies
    9
    Views
    833

    Its a amp clamp, not a ma clamp, the fieldpiece...

    Its a amp clamp, not a ma clamp, the fieldpiece and fluke amp clamps are no better than the klein meter.
  32. Thread: BIG ice maker.

    by redback
    Replies
    15
    Views
    1,254

    Ive worked on snowkey units in australia, the big...

    Ive worked on snowkey units in australia, the big ice flakers are built very well, and very good to work on, the quality is not comparable to the small machines used in hotels and clubs.
  33. Replies
    3
    Views
    318

    cool storage, hops

    my employer got me to service some large cool stores full of hops, the customer is stacking them under evaps, can these combust if they get wet in a cool store, at a storage temp of 2C.
  34. Thread: suction cups

    by redback
    Replies
    0
    Views
    471

    suction cups

    Anyone use these hand held vacuum cups or similar, i need one to lift cool room panneling with groves not flat panneling, maybee even lift some a/c units and small single door refrigerated cabinets,...
  35. Replies
    21
    Views
    1,436

    I will get the wholesalers to order the longer...

    I will get the wholesalers to order the longer power element, they claimed none were available, but they must be.

    Thanks all.
  36. Replies
    21
    Views
    1,436

    The coil is a lu-ve, model no: cs71h 4220 n6

    The coil is a lu-ve, model no: cs71h 4220 n6
  37. Thread: Fluke CNX3000

    by redback
    Replies
    16
    Views
    1,963

    Im not leaving a $800 iphone 5, a charger, a...

    Im not leaving a $800 iphone 5, a charger, a power cord, a multimeter and a fieldpiece attachment on site data logging, manufacturers dont have basic stuff like passwords in multimeters and stuff to...
  38. Replies
    10
    Views
    3,259

    I have the twin valve cps blackmax and twin valve...

    I have the twin valve cps blackmax and twin valve cps vortex, not the chrome versions just the standards, the blackmax bug me as the valves take for ever to open and close unlike the vortex, the...
  39. Replies
    21
    Views
    1,436

    It has a proper refrigeration distributor with...

    It has a proper refrigeration distributor with about 40 little 1/4” lines maybee more, its not glycol, even states r22 etc on the coil.


    If i move the txv to to the suction header end that will...
  40. Replies
    21
    Views
    1,436

    Cool room evaporator install.

    I got a cool room evaporator that seems odd.


    The coil is about 17 to 18 ft long, i went to fit a new tx valve to the brand new coil and found the distributor up one end of the coil and the...
  41. Replies
    6
    Views
    617

    I replaced a noisy bi-directional condenser fan...

    I replaced a noisy bi-directional condenser fan motor.


    there are no bolts or screws holding this unit in, there are only two levers at the front, turning both levers 45 degrees raises or lowers...
  42. Replies
    6
    Views
    617

    removable refrigeration unit

    I worked on this unit the other day, it was very nice to work on, no smoke alarms to disable, no carting heavy oxy sets or gas bottles, no work permits or safety inductions no one getting in my way,...
  43. Replies
    60
    Views
    5,702

    According to the testo tool, the FP leak testers...

    According to the testo tool, the FP leak testers were tested in a room ambient of 22C or 72F

    Here are photos of a leak i found on a large 15 foot freezer coil in a freezer room at -22C, the...
  44. Replies
    18
    Views
    2,386

    I have the fluke 902 paid $436 for it in...

    I have the fluke 902 paid $436 for it in australia, crap meter.
  45. dektite.

    dektite.
  46. Replies
    0
    Views
    370

    greenlee dm-510a

    Anyone using this meter, any good?
  47. Replies
    46
    Views
    5,638

    My boss refuses to buy me a remote controlled...

    My boss refuses to buy me a remote controlled milwaukee.
  48. Replies
    46
    Views
    5,638

    http://www.youtube.com/watch?v=Zaa0Nu258HE

    http://www.youtube.com/watch?v=Zaa0Nu258HE
  49. Replies
    2
    Views
    497

    Modern day a/c units

    is a reverse cycle a/c unit, with an inverter compressor, superior to that of a a/c unit that has a digital scroll compressor and a electronic soft starter.
  50. Replies
    8
    Views
    987

    you need to work out, what you want from a...

    you need to work out, what you want from a digital analyser, for example I require data logging to check oil cooling circuits on screw compressors under heavy loads or low ambiat conditions, or data...