  1. rc5115 Do you still have the 33csdca090 damper...

    rc5115
    Do you still have the 33csdca090 damper motors and if so how much.

    Thanks
  2. Thread: Windows 8

    by fac 213
    Replies
    16
    Views
    1,660

    Ok Windows 8 seems to have issues, but has...

    Ok Windows 8 seems to have issues, but has anybody tried to load carrier service tool 2.2 onto windows 8 ? And thanks for the imput.
  3. Thread: Windows 8

    by fac 213
    Replies
    16
    Views
    1,660

    Windows 8

    Hi I am looking to get a new lap top. It comes with windows 8. Has anybody tried setting up carrier service tool on windows 8 yet. The version of service tool I have is 2.2.
    Thanks
  4. Replies
    0
    Views
    453

    Johnson Fan Controller

    I have two new P66AAB-39C single Condenser Fan Speed
    Controllers. Trane part number-436704290100. Operating range
    320 to 410 psig. Want to sell them togehter. Make me a reasonable offer.
  5. Thread: 33cst carrier

    by fac 213
    Replies
    1
    Views
    382

    33cst carrier

    On a 33cst monitor stat in config 1, there is a override time limit, and a timed override hours. Does anyone know what the difference is. I looked in the config book and can not find it. Thanks for...
  6. Replies
    0
    Views
    712

    York Rooftop info

    I have two York Rooftop units, that I am going to replace. Problem is the town inspector wants to know the weight of the unit, and the weight of the new unit, with the curb adabter. I have the cut...
  7. Replies
    5
    Views
    1,497

    Carrier varislide ecomonizers

    I have a few units that have the old slide econonizers. I called carrier to order the drive screw that connects to the motor and moves the damper up or down. Carrier can not find a part number. Does...
  8. Replies
    41
    Views
    6,251

    I think the kit Trane provides to correct the...

    I think the kit Trane provides to correct the failures is KIT15855 ( Trane kit number). I called for a price, quite expensive for some wires, and a contactor.
    Has anyone installed this kit ? Any...
  9. Replies
    41
    Views
    6,251

    Thanks for the info. I will check with my Trane...

    Thanks for the info. I will check with my Trane distributor tomorrow. I thought about installing a 24v isolation relay to break the 2 legs going to the cfm. The relay woud be powered from w1 going to...
  10. Replies
    41
    Views
    6,251

    I know the kit and wiring harness exists for the...

    I know the kit and wiring harness exists for the smaller Trane units with the negative gas pressure set up, but I am refering to a 12.5 ton voyager rooftop unit. If they did make a change , where can...
  11. Replies
    0
    Views
    530

    Old 20 ton York

    I have three york, DACW240 rooftop units. Does someone have the sequence of operations for the heat section. I have the wiring diagram. Thanks
  12. Thread: 25 Ton Voyager

    by fac 213
    Replies
    28
    Views
    2,149

    I believe trane uses a 2 pole contactor for the...

    I believe trane uses a 2 pole contactor for the Evap motor, even though it is
    3 phase. Did you checvk the Pri tap on the transformer to see if it matches the incomming voltage. Is the Transformer...
  13. Replies
    14
    Views
    2,140

    fxb80, I have two floppy's for the old service...

    fxb80,
    I have two floppy's for the old service tool 4 version 1.0. Is that what you are looking for? My e-mail is in my profile.
  14. Replies
    4
    Views
    1,198

    3 ton unit

    I am looking for one unit. How much are you selling it for. My e-mail is in my profile. Please let me know.

    Thanks
  15. Thread: Carrier

    by fac 213
    Replies
    6
    Views
    896

    Zone Controllers

    Acomo

    I have two Zone controllers, one bypass controller, two temp stats. Took them out of a job that had the old ACS program. They might be locked, I can not remember if I removed the lock with...
  16. Replies
    6
    Views
    1,602

    Had the same problem. The smoke detectors were...

    Had the same problem. The smoke detectors were system sensor type. The came factory installed in new Trane units. The units (2) serviced the kitchen area. They keep tripping and then the Fire Trucks...
  17. Replies
    16
    Views
    4,425

    Hope this helps I have not used it but it sounds...

    Hope this helps I have not used it but it sounds good


    Industrial/Commercial HVAC condensate pans are a common source of problems facing healthcare facilities. The two main issues being Indoor...
  18. Thread: Trane Varitrac

    by fac 213
    Replies
    3
    Views
    638

    Trane Varitrac

    I have a Trane Varitrac VAV system . It consists of two VAV boxes, and one bypass damper. Their is a control panel on the job and I can access Zone and system status and setup. The problem is the fan...
  19. Replies
    41
    Views
    6,251

    Sorry about the double post

    Sorry about the double post
  20. Replies
    41
    Views
    6,251

    Trane CBM failures

    I have had several CBM with the same problem, just running and no heat. Trane exchanged them under warranty. In fact they said hold on to the CBM
    they did no want it back. Today I had another CBM...
  21. Replies
    41
    Views
    6,251

    I have had several CBM with the same problem,...

    I have had several CBM with the same problem, just running and no heat. Trane exchanged them under warranty. In fact they said hold on to the CBM
    they did no want it back. Today I had another CBM...
  22. Replies
    7
    Views
    747

    Thanks r404a for the suggestions. It will take...

    Thanks r404a for the suggestions. It will take some doing, but I will find the leak. The machine is working like a champ right now. I still have the probe on the discharge line, and will stop every...
  23. Replies
    7
    Views
    747

    Went back to the nightmare job, the unit is FULL...

    Went back to the nightmare job, the unit is FULL of ice, and the discharge temp stayed below 200. There is a leak somewhere. I soaked the sol vales, access fittings, and all the rest with bubbles,...
  24. Replies
    7
    Views
    747

    Went back to the job today. The recorder showed a...

    Went back to the job today. The recorder showed a discharge line temp at 195 on the high end and 110 on the low end. Called the Tech guys at Manitowoc, and we determined the unit was low on gas. I...
  25. Replies
    7
    Views
    747

    BY1894N Remote Lockout on saftey limit 4

    Have a Manitowoc Ice Machine that Locks out on Saftey Limit 4 every once in a while. Pressures are 265-43 ( 265 taken at liquid line ) @ 80 outdoor temp on start up. Suction drops to 30 right before...
  26. Replies
    4
    Views
    1,485

    Go to honeywell.com I think you need a...

    Go to honeywell.com
    I think you need a vr8305q4146 two stage valve
  27. Replies
    23
    Views
    2,306

    Dgruber I have service literature and overhaul...

    Dgruber

    I have service literature and overhaul for Trane Semi Hermetic Compressors
    Model E. It might help you out if you plan to to do a overhaul. Send me a fax number, and I will send you the...
  28. Replies
    17
    Views
    1,455

    Ask Him to explain how you size sol valves. Alot...

    Ask Him to explain how you size sol valves. Alot of Techs think a B6 sporlan will work on a 1 hp system. (just a example)
  29. Replies
    48
    Views
    3,834

    Manitowoc 452 Ice Machine

    Might have a water valve that sticks open sometimes. You need to check the codes if this happens again to see what the machine is locking out on.
  30. Replies
    1
    Views
    591

    Trane Voyager Combustion Fan Failures

    I have a Trane 12.5 Ton Rooftop unit. I replaced the Combustion Fan Motor last April because the motor was always running. Today on a P.M. the motor was burned up . (you could see the windings...
  31. Replies
    32
    Views
    3,202

    Okay Mr Air 2 spare, Maybe I was not completely...

    Okay Mr Air 2 spare, Maybe I was not completely correct, when I said their might be the wrong piston. The correct name in a nozzle, Each Bohn coil comes with two. They are in a little plastic bag...
  32. Replies
    32
    Views
    3,202

    Your superheat seems high, if it a semi I try to...

    Your superheat seems high, if it a semi I try to get 20 Degrees min at the compressor.
    Seems like you might have the incorrect piston in the distributer. If you call bohn they will tell you the...
  33. Replies
    10
    Views
    1,270

    Maybe it is not a pump down system. Could it be a...

    Maybe it is not a pump down system. Could it be a rooftop unit with a low pressure time delay relay for winter start ? If so then the unit cold be low on gas, the TEV could be a problem, or the drier...
  34. Replies
    56
    Views
    8,748

    I can not believe that this system is not a punp...

    I can not believe that this system is not a punp down , but then again I have seen some strange setups. So if I understand you the temperature control inside the box cycles the compressor contactor....
  35. Replies
    56
    Views
    8,748

    I live up north and I do not know what kind of...

    I live up north and I do not know what kind of stores, or Resturant corp you work for. Looking at the pictures and reading what you have said, I would think twice about going there.
  36. Replies
    56
    Views
    8,748

    Disconnect the X terminal on the time clock, then...

    Disconnect the X terminal on the time clock, then turn the dial and send the unit into a defrost. The unit should pump down and the heaters should come on. If you have a aux contacts on the...
  37. Replies
    5
    Views
    1,783

    Check your Wires, You might have wires going to 1...

    Check your Wires, You might have wires going to 1 and 4 reversed. 1 gets power and their might be a jumper to 2. 2 is common to 3 and 4.
    Hope this helps
  38. Replies
    11
    Views
    1,965

    Call your Rep, and ask him to send you a FREE bin...

    Call your Rep, and ask him to send you a FREE bin extension kit. This kit allows you to move the bin stat further down into the bin. The ice will now come in contact with the bulb sooner. You did not...
  39. Replies
    11
    Views
    1,327

    you couldnot open the program Frank

    you couldnot open the program

    Frank
  40. Replies
    11
    Views
    1,327

    O K Balibe I followed you instructions, but I...

    O K Balibe I followed you instructions, but I need to get to the job , delete the UC16 in service tool and upload, then make a new algo on a on a different point. (dry run) But in the UC -SEPT** ,...
  41. Replies
    11
    Views
    1,327

    I am not familiar with the quick look up feature....

    I am not familiar with the quick look up feature. Where can I access it?
    Also, I have Comfortview 3.1 on the main computer for the building. I have Service Tool 1 which I purchased 4/07. I knew...
  42. Replies
    11
    Views
    1,327

    uc16

    OK lets start with the Rooftop unit. The unit is a VAV cooling only, and has a morning warm up control in the unit. I have it set at 65 degrees (retun air). The unit also has the ability to drive...
  43. Replies
    11
    Views
    1,327

    carrier uc16 program

    I have a uc16 controlling a rooftop unit by a time schedule. Hwout _1 powers a rib relay to start and stop the unit. Also on the CCN are 15 comfort ID VAV boxes. I also have a SPT (T-55), which in in...
  44. Looking for capacity on Old Chrysler Air Temp unit

    A new customer is looking to replace a self contained water cooled upflow Chrysler Air Temp air conditioning unit. Model #1005-1, serial #5107995. Compressor is Chrysler radial compressor, model...
  45. Replies
    1
    Views
    498

    help-- info on how to reset or purge a bridge so...

    help-- info on how to reset or purge a bridge so it resets to buss 0 element 75
Results 1 to 45 of 45