  1. Replies
    1
    Views
    119

    Trane Chiller RTAC 375

    Anybody can explain what is this Error in Binding view.Picture attached.Thanks.
  2. Replies
    0
    Views
    174

    McQuay Chiller PEH 100

    McQuay Chiller 100 not Loading what can be the possible cause.Thanks.
  3. Replies
    12
    Views
    2,922

    Thanks

    I am no more working on that site.Anyhow I am thankful to you.
  4. Replies
    0
    Views
    157

    McQuay PEH100 Chiller

    Which Software is used to Program Microprocessor Control Board 860-654873B. Thanks.
  5. Thread: Mcquay Expert

    by coldrig
    Replies
    2
    Views
    396

    Sorry if I did not put my question right.My...

    Sorry if I did not put my question right.My question can we replace faulty board with any old with same model number.I don't know where they use old board so what is procedure to reset and install...
  6. Thread: Mcquay Expert

    by coldrig
    Replies
    2
    Views
    396

    Mcquay Expert

    We have Mcquay Centrifugal Chiller PEH100,with Control Board P/N 860-6548738-5c. These borads are obsolete but old boards are available on Ebay. My question is available board p/n is same only last...
  7. Thread: Alerton VLC

    by coldrig
    Replies
    0
    Views
    325

    Alerton VLC

    Anybody have LTBT-TM-GEN4VLC_13 for VLCs Installation and Operation Guide.Thanks.
  8. Replies
    6
    Views
    1,703

    Thanks

    Got it.
  9. Replies
    6
    Views
    1,703

    I also need pdf manual about visual Logic if you...

    I also need pdf manual about visual Logic if you still have copy please send me also I will be thankful to you.My email is in my profile.Thanks.
  10. Replies
    0
    Views
    183

    Trane RTAC400 TO JCI N2 Network

    Is it possible to connect RTAC400 with JCI N2 network without BCU. Front end is Tridium Niagra. Thanks.
  11. Replies
    3
    Views
    479

    Hi Mallron, Thanks.

    Hi Mallron, Thanks.
  12. Replies
    21
    Views
    2,683

    It is not contrast problem.What do you mean by...

    It is not contrast problem.What do you mean by FWIW.Thanks.
  13. Replies
    21
    Views
    2,683

    I have again problem with other chiller,Chiller...

    I have again problem with other chiller,Chiller is working fine and I check with techview every reading is ok but nothing on display do you have any idea if I can buy only LCD Module as spare not...
  14. Replies
    3
    Views
    479

    TRANE TRACER SUMMIT 16

    We have three PC with Tracer Summit 16 installed and working.Is it possible to copy one of them on Laptop with Licence so that we can Work with Trane VAVs which are in other building which is not...
  15. Thread: Mcquay WSC-126

    by coldrig
    Replies
    0
    Views
    261

    Mcquay WSC-126

    Anybody can explain how to replace BACnet communication Module on Mcquay WSC-126 Chiller.
    Thanks.
  16. Thread: Mcquay Expert

    by coldrig
    Replies
    1
    Views
    411

    Mcquay Expert

    I want to ask if we need to replace faulty Microtech ii 3302752 Universal Communication Circuit Board,is it just remove faulty module and fix new one or it need some programming also.Thanks.
  17. Replies
    21
    Views
    2,683

    Thanks for Advice,I will try myself safely If I...

    Thanks for Advice,I will try myself safely If I will see it is not working then I will call Trane Technician.
  18. Replies
    21
    Views
    2,683

    It was good hint and I tried to adjust Contrast...

    It was good hint and I tried to adjust Contrast but no use I think problem is in circuit,some component heatup because after few minutes backlight disappear.
  19. Replies
    11
    Views
    948

    Thanks for lot of useful information,I will check...

    Thanks for lot of useful information,I will check on Monday and then let you know. VAVs are varitrane.
  20. Replies
    21
    Views
    2,683

    I got the correct cable and it is communicating...

    I got the correct cable and it is communicating even with old Display although Display screen is blank only backlight but I can
    read all configuration on TechView screen,but I don't see backup
    and...
  21. Replies
    21
    Views
    2,683

    I am agree with you it is not DIY operation.We...

    I am agree with you it is not DIY operation.We have another same chiller which is working OK so can I take backup from there and load it other Display unit,as it is 100% same configuration.I download...
  22. Replies
    21
    Views
    2,683

    (Tech View)Is there any restriction like Licence...

    (Tech View)Is there any restriction like Licence or password or it is free to download and use.When I will hookup via serial cable will it read configuration from chiller memory.Then I will restore...
  23. Replies
    21
    Views
    2,683

    Trane Adaptive Control

    There was Faulty Adaptive Control Display unit on RTAC200 Trane Chiller sticker on backside is X13650827-06 I replaced it with same number X13650827-06 from ebay. when I give it 24Vdc power it shows...
  24. Replies
    11
    Views
    948

    In that setup Screen there is no box to Replace...

    In that setup Screen there is no box to Replace Pressure Dependent to Pressure Independent.
  25. Replies
    11
    Views
    948

    One more question if you can reply,It is showing...

    One more question if you can reply,It is showing Pressure Dependent VAV,Where as these are Pressure Independent VAVs because there are differential pressure transducers,does it make any difference or...
  26. Replies
    11
    Views
    948

    BCU is BMTX and it has Two comm4 links.I...

    BCU is BMTX and it has Two comm4 links.I succeeded to communicate with VAV. As there is no network cable so at the moment I can just connect one by one as required,until we pull cabel. Any how I am...
  27. Replies
    11
    Views
    948

    MP581 is only used for Pumps which is connected...

    MP581 is only used for Pumps which is connected on Comm5 and Chillers are connected on Comm3.At the moment VAVs are stand alone there Built in Cards DDC/U.C.M Control board these are UCM4 and not...
  28. Replies
    11
    Views
    948

    Trane VAV Programming

    We have site with Trane BAS System Tracer Summit Ver16.There are 3 Trane Chillers RTAD and 3 Ch water pump 2 working 1 standby.1 BCU and 1 MP581 Controller.There are few TRANE VAVs are there on there...
  29. Replies
    0
    Views
    336

    VFD-IGBT Question

    Anybody has idea how to check Mitsubishi IGBT PM200DVA120 With Talon VFD Analyzer. Normal IGBT has gate but this IGBT has many control pins. IGBT drawing is attached.Thanks.
  30. Replies
    0
    Views
    341

    SIEMENS VAV PINOUT

    We have Siemens VAVs GDB181.1E/3 with 6 pins for converter connections.Now we receive same Model with 7 Holes for converter connections so AST11 Converter is not communicating.Anybody have Idea how...
  31. Replies
    0
    Views
    298

    SIEMENS VAV static Calibration Question

    Any body have idea how ACS941 Tool calibrating flow rate on Pressure difference.In case of Johnson controls VAV Calibration we need to add Duct size but in case of Siemens VAV there is no requirement...
  32. Replies
    2
    Views
    393

    When I attach HC7410 and try to check DCU address...

    When I attach HC7410 and try to check DCU address it is not showing anything so I don't know how to start communication and assign some address to PCU. Only then it can be possible to download Bin...
  33. Replies
    2
    Views
    393

    I/net PCU7718 Networking problem

    We have problem with I/net 2000 networking ,there are around 25 PCU7718 AND PCU7756 Controllers one of them has some problem due to that all controllers are showing question marks and after few...
  34. Replies
    3
    Views
    644

    Thanks for Default IP,I use same series IP in my...

    Thanks for Default IP,I use same series IP in my PC and I can ping Xenta527 NPR. But I don,t see it online through Inet200 configuration window. What is reason and If I want to change IP of Xenta527...
  35. Replies
    3
    Views
    644

    Tac Xenta527 NPR

    Hi,We have Inet2000 system.I want to configure Xenta 527NPR. According to Manual it can be configured via RS232 cable. Is it possible to configure it via Ethernet cable also. Thanks.
  36. Replies
    0
    Views
    322

    OS2 ULTIVIST UPGRADING

    We have one old site with ULTIVIST on OS/2,Owner want to upgrade their system.There are DMS 350 Controllers. So which software and controllers are most suitable to upgrade this system.Thanks.
  37. Replies
    8
    Views
    1,403

    Hi Dan

    I will check about backup file,I am not at same site at this time Ithink front end is EBI,let me check it tomorrow
    if you can give me hint about backup file name.Thanks.
  38. Replies
    8
    Views
    1,403

    Very nice information, We are AC service...

    Very nice information, We are AC service co.Honeywell don't sell us Care software is there any other source from where to buy Care software.Thanks.
  39. Replies
    8
    Views
    1,403

    SKWSPROUL

    I am thankful to your reply
  40. Replies
    8
    Views
    1,403

    Honeywell XCL5010 Question

    We have one faulty XCL5010 Controller,When we will replace it with new one is there any programming required or it will upload itself.Thanks.
  41. Replies
    1
    Views
    850

    Tac i/net Seven CD Key

    We have HVAC System with Tac i/net Seven 2.21 installed,There is virus in PC and we want to Format it.We have original CD but Key is not written on it,the person who install it long back left company...
  42. Replies
    0
    Views
    372

    Telemecanicque LT6 Motor Controller

    I have one new site with Telemecanicque LT6 Motor
    control Modules,One Module is not working and other
    has very small Star to Delta transition time,to check
    the problems LA9PA620 Software...
  43. Replies
    0
    Views
    461

    Mcquay Microtech ll Code

    Anybody have idea what is meaning of Microtech code like
    PCO2 MQ3BL0
    PCO2 000BM0
    PCO2 000BL0
    PCO3 MQ0BM0
    Or any refrence litraure to understand these codes.Thanks.
  44. Replies
    4
    Views
    1,110

    Thanks for reply.I think revision is for...

    Thanks for reply.I think revision is for controller and serial card for communication can be same to work with both controllers.
  45. Replies
    4
    Views
    1,110

    McQuay MicroTech II

    What is difference between PCO3MQ0BS0 and
    PCO3MQ0BM0.We have one faulty Lon Serial Card in PCO3MQ0BS0.Can we replace it from
    spare controller PCO3MQ0BM0.Are both cards
    compatible.Thanks.
  46. Replies
    5
    Views
    1,835

    will you tell me what Data points you...

    will you tell me what Data points you required.Thanks.
  47. Replies
    5
    Views
    1,835

    York YK Centrifugal Chiller

    We have 3 YK series york chillers R134a cooling capacity 1500 Tons.One of the chiller is surging too much condenser Sub cooling is around 10 Deg F.Its motor is 3.3Kv,Ampares are are fluctuating...
  48. Replies
    2
    Views
    726

    AHU reverse connections

    Normally Ahu Water supply is from down and return from up,but at one site contractor connect Supply from Up so what can be effect on performance of Ahu.This Ahu is 948 MBH capacity.Thanks.
  49. Replies
    1
    Views
    778

    Invensys MN 620

    Where can I get Invensys MN 620 Application Template.Thanks.
  50. Replies
    9
    Views
    1,025

    Model LD 100 Dual Source Made in Ireland

    Model LD 100 Dual Source
    Made in Ireland