Search:

Type: Posts; User: HVAC_Marc

Page 1 of 18 1 2 3 4

Search: Search took 0.06 seconds; generated 57 minute(s) ago.

  1. Replies
    18
    Views
    550

    That looks like a low-boy to me. A dual boxed...

    That looks like a low-boy to me. A dual boxed FAU, one box is the blower unit, the other box is the exchanger/burner area.
  2. Replies
    9
    Views
    876

    maybe it's an illusion but is the 3/8 line...

    maybe it's an illusion but is the 3/8 line flattened too?

    they probably shattered the siding by drilling it wrong.
  3. Replies
    1
    Views
    201

    Wildomar, CA - Office Work Wanted

    I'm helping out a friend. She has 2 young children and is in desperate need of an office style job. She has intermediate computer skills - office software and the like. She has exceptional human...
  4. handy hacks tore out the old low-boy... and this...

    handy hacks tore out the old low-boy... and this is what you get...
  5. https://www.youtube.com/watch?v=VMgjZrFLWwA&featur...

    https://www.youtube.com/watch?v=VMgjZrFLWwA&feature=youtu.be
  6. i have the harbor freight kit. it is just as...

    i have the harbor freight kit. it is just as durable as store bought bits. Irwin has a full line of safety bits, too. I think they're sold at Lowe's.

    Edit: the kit does NOT have the 5 star...
  7. Replies
    7
    Views
    512

    it cancels it, but there is no other Like button...

    it cancels it, but there is no other Like button to choose
  8. you'll get in fine. be prepared to get lots of...

    you'll get in fine. be prepared to get lots of schit from some on this forum. they're like rabid dogs.
  9. ooooo...so close, yet so far. i had a GMS. ...

    ooooo...so close, yet so far. i had a GMS. sorry :(
  10. ive always been a piston guy. never a problem,...

    ive always been a piston guy. never a problem, unless someone uses very poor brazing practices.
  11. damn dude! you're pex and wiring looks like...

    damn dude! you're pex and wiring looks like schit!! ::DD:


    (i dont see any issues)


    looks good. it really takes bravery to post on WOP. Not many here do it
  12. Replies
    32
    Views
    1,580

    it is still well used in the bedroom... ;)

    it is still well used in the bedroom... ;)
  13. a 5/370 and a 5/440 are the same capacitor size. ...

    a 5/370 and a 5/440 are the same capacitor size. you dont need a new one.
  14. Replies
    23
    Views
    1,106

    dont know. it shouldnt matter if it is recycled...

    dont know. it shouldnt matter if it is recycled or reclaimed. metal is infinitely reusable
  15. Replies
    23
    Views
    1,106

    yes, the copper becomes porous in some way. due...

    yes, the copper becomes porous in some way. due to thinness or some other reason.
  16. yep, the boss wanted the truck there. it's on...

    yep, the boss wanted the truck there. it's on his insurance. I hope you have everything cataloged and documented.
  17. Replies
    23
    Views
    1,106

    i had this happen on a Carrier condenser. all...

    i had this happen on a Carrier condenser. all the bends showed leaks/dye. but nothing else. all i could conclude was that the copper bends were thin enough to hold pressure of the large N2...
  18. Replies
    37
    Views
    2,668

    Me too, probably wont change much... :rolleyes:...

    Me too, probably wont change much... :rolleyes: I'll figure out a code title. Probably a little less self-insulting than what you suggested ;)

    It'll have to be in a locked forum or maybe...
  19. Replies
    37
    Views
    2,668

    been a long time. weather finally broke and we...

    been a long time. weather finally broke and we have grass! not too much hvac going on right now here, and plumbing has been keeping me busy. can't wait to start up the old AC and see what the...
  20. Replies
    16
    Views
    583

    UPS15-58FC

    UPS15-58FC
  21. Replies
    37
    Views
    2,668

    This will soon be a large commercial tool only

    This will soon be a large commercial tool only
  22. [/h] Lennox has... in my area a 17 SEER unit...

    [/h]
    Lennox has...

    in my area a 17 SEER unit vs a 14 SEER unit will never pay for itself. (Buffalo, NY)
  23. Replies
    24
    Views
    3,969

    lots of interest, just none that you can accept

    lots of interest, just none that you can accept
  24. Replies
    37
    Views
    2,668

    here also

    here also
  25. Replies
    37
    Views
    2,668

    max operating pressure of 700 psi. hate to see...

    max operating pressure of 700 psi. hate to see what happens when that 410a system goes haywire....
  26. Thread: Runs good

    by HVAC_Marc
    Replies
    79
    Views
    4,894

    if it was piped like that forever and 'worked...

    if it was piped like that forever and 'worked fine for years' then i would think the bigger problem lies elsewhere.
  27. Thread: Runs good

    by HVAC_Marc
    Replies
    79
    Views
    4,894

    So then the problem lies not in the ugly reducing...

    So then the problem lies not in the ugly reducing job?
  28. too much draft

    too much draft
  29. Replies
    744
    Views
    147,238

    Today - "my new stove won't work" says the...

    Today - "my new stove won't work" says the customer. "A daughter's friend installed the connectors. He says my new stove is bad and has to go back."

    (pull stove out, start laughing)

    I turned...
  30. Replies
    11
    Views
    2,116

    looks like a radon vent to me... a plumbing vent...

    looks like a radon vent to me... a plumbing vent like that would be in serious violation of the code
  31. Thread: Vacuum pump?

    by HVAC_Marc
    Replies
    20
    Views
    898

    we run everything from Harbor Freight to top of...

    we run everything from Harbor Freight to top of the line models. you need to buy one in your budget that displaces as much as possible in the shortest amount of time.
  32. Replies
    16
    Views
    583

    eh, the 2 missing bolts are why it's so noisy ;)

    eh, the 2 missing bolts are why it's so noisy ;)
  33. Replies
    16
    Views
    583

    and no one has mentioned that the valves that...

    and no one has mentioned that the valves that allow water flow to the pump are turned OFF? open the valves, the pump will get quieter and last longer, too...
  34. Replies
    1
    Views
    249

    you need a new one

    you need a new one
  35. Replies
    19
    Views
    1,396

    simple. put a line locator on it that sets a...

    simple. put a line locator on it that sets a certain frequency on the electrical wire. then look for it with the locator on the roof. electricians use these all the time to trace circuits. try...
  36. Replies
    16
    Views
    603

    missing/corroded thermocouple jumper?

    missing/corroded thermocouple jumper?
  37. Replies
    12
    Views
    472

    you're going to need that hard start kit once...

    you're going to need that hard start kit once your compressor starts to fail because of that stop leak contaminant in there....
  38. I would think it would be a violation of the UL...

    I would think it would be a violation of the UL listing for the mobile home furnace to be installed in a "standard" structure. Can it be done? yes. will it work? probably.

    Ask your insurance...
  39. Replies
    33
    Views
    3,975

    ive never heard of anyone getting sick from...

    ive never heard of anyone getting sick from uncleaned steel ducts. i've seen ducts with dead animals, dust and debris 2" thick and no one has been ill. there's a LOT of hype and "marketing" (lies)...
  40. Replies
    4
    Views
    227

    I am in the Great Lakes region of NY and pellets...

    I am in the Great Lakes region of NY and pellets are my primary source of heat, propane is my second stage heat. pellets are by far, more economical than any other fuel source. the furnace you...
  41. Thread: 3 home owner

    by HVAC_Marc
    Replies
    2
    Views
    333

    and upgrade to the existing unit? not that i...

    and upgrade to the existing unit? not that i know of. if you want a more efficient unit yank it out and replace it with one.
  42. Replies
    2
    Views
    242

    it's normal operation. very few boilers nowadays...

    it's normal operation. very few boilers nowadays are "maintaining" style.
  43. Replies
    53
    Views
    2,301

    if it didnt cool due to being undersized and the...

    if it didnt cool due to being undersized and the duct system supports a larger size, then it will most likely correct your problem by going up in size. any tech who knows what a manual J is can do...
  44. Replies
    53
    Views
    2,301

    going too big on a too-small duct system will...

    going too big on a too-small duct system will guarantee it wont cool well, if at all
  45. Replies
    53
    Views
    2,301

    you can go up provided the duct system will...

    you can go up provided the duct system will support it. your company can perform a load calc to determine what you need and then make measurements to determine what the duct system will support.
  46. Replies
    12
    Views
    331

    the tubing port is usually a combo barbed fitting...

    the tubing port is usually a combo barbed fitting and check valve. it threads into the pump and is easily broken or cracked where the barbs mate to the rest of the fitting.

    i dont think this...
  47. sounds like a method of cutting corners, to me.

    sounds like a method of cutting corners, to me.
  48. Thread: WOW

    by HVAC_Marc
    Replies
    23
    Views
    3,765

    there's a picture on here that shows that it does...

    there's a picture on here that shows that it does fit the outside of the concentric. what exactly are you trying to say?
  49. Replies
    32
    Views
    1,744

    those are dielectric nipples

    those are dielectric nipples
  50. if you put an amp clamp around a 3/4" pipe and...

    if you put an amp clamp around a 3/4" pipe and see amperage, then that is a problem. if you put a volt meter on any pipe and also on a good non-boiler ground and measure voltage, then that is a...
Results 1 to 50 of 893