05-15-2013, 09:33 AM
Thread: BACnet.....
by control$- Replies
- 10
- Views
- 1,168
"the ALC exclusive territory is being pushed by...
"the ALC exclusive territory is being pushed by the ALC rep even though the promise was that there would be multiple ALC vendors"
- If your local ALC Rep sucks then ALC will suck. I have to compete... -
04-24-2013, 02:59 PM
Thread: ivu and apple/mac
by control$- Replies
- 4
- Views
- 152
The WebCTRL version is already out in beta.
The WebCTRL version is already out in beta.
-
04-24-2013, 02:56 PM
Thread: WebCTRL Exp and Channels Explained
by control$- Replies
- 3
- Views
- 98
Exp = Expansion board #. chan = channel Exec 6...
Exp = Expansion board #.
chan = channel Exec 6 (Legacy) programs, yes you are correct. 4x = AO, or Pneumatic output
1x = DO, 2x = DI, 3x = AI
Yes there is more to it, but that's all most ever use. -
04-23-2013, 03:00 PM
Thread: Automated Logic Question
by control$- Replies
- 4
- Views
- 207
AS a ALC tech I agree with the above to a point....
AS a ALC tech I agree with the above to a point. You have older controls, hope they are EXEC B and not EXEC 6. Legacy has more of a learning curve and special tools.
-
04-23-2013, 02:54 PM
Thread: BBMD vs VPN
by control$- Replies
- 15
- Views
- 437
The VPN took care of the DSL IP's. Your right,...
The VPN took care of the DSL IP's. Your right, looking at the project I needed to use BBMD's also.
-
04-22-2013, 05:04 PM
Thread: BBMD vs VPN
by control$- Replies
- 15
- Views
- 437
I've used VPN's were needed. Example: (8)...
I've used VPN's were needed. Example: (8) buildings with DSL's and different IP addresses and I provide the routers.
Mostly BBMD's are used on sites were you are given have several static IP's on... -
03-22-2013, 09:23 AM
- Replies
- 5
- Views
- 296
Or 59 devices if it's a legacy UNI/59 in WebCTRL.
Or 59 devices if it's a legacy UNI/59 in WebCTRL.
-
03-20-2013, 09:46 AM
Thread: Invensys LON to Tridium conversion
by control$- Replies
- 43
- Views
- 1,311
Thats was correct back in the day, I left...
Thats was correct back in the day, I left Invensys in 2001. Every time a new tech showed up he would change the entire database...Your bringing back memories. No matter how bad or buggy this lon junk...
-
03-04-2013, 10:40 AM
Thread: UPS Battery Monitoring
by control$- Replies
- 12
- Views
- 357
Can't imagine a alarm you would miss with APC and...
Can't imagine a alarm you would miss with APC and SNMP. Have you seen the mib file?
-
03-01-2013, 09:32 AM
Thread: UPS Battery Monitoring
by control$- Replies
- 12
- Views
- 357
Can't go wrong with APC. They all talk SNMP...
Can't go wrong with APC. They all talk SNMP making it easy to monitor and alarm with EMS systems.
-
02-26-2013, 09:34 AM
Thread: Control Valve Cv question
by control$- Replies
- 2
- Views
- 398
Very slight loss in cooling, unless at the very...
Very slight loss in cooling, unless at the very jagged edge you'll never see the differnce. But you'll get slightly better control.
-
02-25-2013, 09:26 AM
Thread: Automated Logic- Device Instance
by control$- Replies
- 17
- Views
- 726
Some dealers just didn't go WebCTRL till late. We...
Some dealers just didn't go WebCTRL till late. We STOPPED installing Supervision in 2001 with 1.5.
-
02-21-2013, 10:10 AM
Thread: Single Phase VFD's
by control$- Replies
- 7
- Views
- 346
I've used SmartFan Nimbus on small 1 phase fans...
I've used SmartFan Nimbus on small 1 phase fans with good results.
-
02-11-2013, 03:13 PM
Thread: Central Plant Efficientcy
by control$- Replies
- 16
- Views
- 854
Total central plant system at .5kw/ton is...
Total central plant system at .5kw/ton is excellent, thanks for the feedback. Been trying to get my average below 1.00 kw/ton with some success. Got it down to around .8 at times. (5) chillers and...
-
01-31-2013, 09:27 AM
- Replies
- 26
- Views
- 1,293
Hell it wasn't. That old Atari was great little...
Hell it wasn't. That old Atari was great little computer. It ran XPSI and hyperterm.
-
01-16-2013, 09:37 AM
Thread: Central Plant Efficientcy
by control$- Replies
- 16
- Views
- 854
I agree. Many factors and many different systems...
I agree. Many factors and many different systems can lower the number. But it would seem to be a very easy question.
-
01-16-2013, 09:25 AM
Thread: Central Plant Efficientcy
by control$- Replies
- 16
- Views
- 854
I run into chiller plants that all seem to have...
I run into chiller plants that all seem to have .45-.5 KW/ton at the chillers. Great, but meaningless if the energy is wasted all around the system. The only way I know to measure how efficient a...
-
01-14-2013, 12:33 PM
Thread: Central Plant Efficientcy
by control$- Replies
- 16
- Views
- 854
Central Plant Efficientcy
What is a good KW/Ton for an entire central plant. This would include towers, primary and sec CHW pumps and CW pumps. I generally see around .45-.5 KW ton at the chillers. When I add in all the KW...
-
01-09-2013, 09:30 AM
Thread: what constitues a "control guy"
by control$- Replies
- 28
- Views
- 2,803
I love when cutting over existing equipment on...
I love when cutting over existing equipment on jobs, and then hearing "it works fine for years". When you can finally see all the bad valves binding damper and broken actuators on a pretty graphic,...
-
12-31-2012, 10:06 AM
Thread: what constitues a "control guy"
by control$- Replies
- 28
- Views
- 2,803
Holiday?? Job has to be finished by years...
Holiday?? Job has to be finished by years end...24-7 equals..good I have 17 hrs left!!
-
12-24-2012, 10:59 AM
Thread: Very Fast Campus Network Performance!
by control$- Replies
- 12
- Views
- 1,044
Shameless plug. Sys is back..and so is his bravo...
Shameless plug. Sys is back..and so is his bravo sierra.
-
12-14-2012, 10:29 AM
- Replies
- 4
- Views
- 311
You'll need to pull some registers from the...
You'll need to pull some registers from the Yaskawa. CAS Modbus Scanner from Chipkin is free, simple and just works. Simply Modbus is better if your experienced with modbus.
I would bet it's a... -
12-14-2012, 10:29 AM
- Replies
- 4
- Views
- 311
You'll need to pull some registers from the...
You'll need to pull some registers from the Yaskawa. CAS Modbus Scanner from Chipkin is free, simple and just works. Simply Modbus is better if your experienced with modbus.
I would bet it's a... -
11-07-2012, 02:02 PM
Thread: Max Masters
by control$- Replies
- 29
- Views
- 1,634
Based on what I've seen using Lon FTT-10,...
Based on what I've seen using Lon FTT-10, Arcnet/bacnet, and MS/TP bacnet. MS/TP gives the most options for iffy communication wiring. For example; I don't know how many times I needed to install a...
-
10-25-2012, 08:29 PM
Thread: ALC System replacement top 5 reasons
by control$- Replies
- 52
- Views
- 3,384
What control did you have an issue with? I can't...
What control did you have an issue with? I can't think of one until your back to exec 4.
Results 1 to 25 of 227