  1. Thread: BACnet.....

    by control$
    Replies
    10
    Views
    1,168

    "the ALC exclusive territory is being pushed by...

    "the ALC exclusive territory is being pushed by the ALC rep even though the promise was that there would be multiple ALC vendors"
    - If your local ALC Rep sucks then ALC will suck. I have to compete...
  2. Replies
    4
    Views
    152

    The WebCTRL version is already out in beta.

    The WebCTRL version is already out in beta.
  3. Replies
    3
    Views
    98

    Exp = Expansion board #. chan = channel Exec 6...

    Exp = Expansion board #.
    chan = channel Exec 6 (Legacy) programs, yes you are correct. 4x = AO, or Pneumatic output
    1x = DO, 2x = DI, 3x = AI
    Yes there is more to it, but that's all most ever use.
  4. Replies
    4
    Views
    207

    AS a ALC tech I agree with the above to a point....

    AS a ALC tech I agree with the above to a point. You have older controls, hope they are EXEC B and not EXEC 6. Legacy has more of a learning curve and special tools.
  5. Thread: BBMD vs VPN

    by control$
    Replies
    15
    Views
    437

    The VPN took care of the DSL IP's. Your right,...

    The VPN took care of the DSL IP's. Your right, looking at the project I needed to use BBMD's also.
  6. Thread: BBMD vs VPN

    by control$
    Replies
    15
    Views
    437

    I've used VPN's were needed. Example: (8)...

    I've used VPN's were needed. Example: (8) buildings with DSL's and different IP addresses and I provide the routers.

    Mostly BBMD's are used on sites were you are given have several static IP's on...
  7. Or 59 devices if it's a legacy UNI/59 in WebCTRL.

    Or 59 devices if it's a legacy UNI/59 in WebCTRL.
  8. Replies
    43
    Views
    1,311

    Thats was correct back in the day, I left...

    Thats was correct back in the day, I left Invensys in 2001. Every time a new tech showed up he would change the entire database...Your bringing back memories. No matter how bad or buggy this lon junk...
  9. Replies
    12
    Views
    357

    Can't imagine a alarm you would miss with APC and...

    Can't imagine a alarm you would miss with APC and SNMP. Have you seen the mib file?
  10. Replies
    12
    Views
    357

    Can't go wrong with APC. They all talk SNMP...

    Can't go wrong with APC. They all talk SNMP making it easy to monitor and alarm with EMS systems.
  11. Replies
    2
    Views
    398

    Very slight loss in cooling, unless at the very...

    Very slight loss in cooling, unless at the very jagged edge you'll never see the differnce. But you'll get slightly better control.
  12. Replies
    17
    Views
    726

    Some dealers just didn't go WebCTRL till late. We...

    Some dealers just didn't go WebCTRL till late. We STOPPED installing Supervision in 2001 with 1.5.
  13. Replies
    7
    Views
    346

    I've used SmartFan Nimbus on small 1 phase fans...

    I've used SmartFan Nimbus on small 1 phase fans with good results.
  14. Replies
    16
    Views
    854

    Total central plant system at .5kw/ton is...

    Total central plant system at .5kw/ton is excellent, thanks for the feedback. Been trying to get my average below 1.00 kw/ton with some success. Got it down to around .8 at times. (5) chillers and...
  15. Hell it wasn't. That old Atari was great little...

    Hell it wasn't. That old Atari was great little computer. It ran XPSI and hyperterm.
  16. Replies
    16
    Views
    854

    I agree. Many factors and many different systems...

    I agree. Many factors and many different systems can lower the number. But it would seem to be a very easy question.
  17. Replies
    16
    Views
    854

    I run into chiller plants that all seem to have...

    I run into chiller plants that all seem to have .45-.5 KW/ton at the chillers. Great, but meaningless if the energy is wasted all around the system. The only way I know to measure how efficient a...
  18. Replies
    16
    Views
    854

    Central Plant Efficientcy

    What is a good KW/Ton for an entire central plant. This would include towers, primary and sec CHW pumps and CW pumps. I generally see around .45-.5 KW ton at the chillers. When I add in all the KW...
  19. Replies
    28
    Views
    2,803

    I love when cutting over existing equipment on...

    I love when cutting over existing equipment on jobs, and then hearing "it works fine for years". When you can finally see all the bad valves binding damper and broken actuators on a pretty graphic,...
  20. Replies
    28
    Views
    2,803

    Holiday?? Job has to be finished by years...

    Holiday?? Job has to be finished by years end...24-7 equals..good I have 17 hrs left!!
  21. Replies
    12
    Views
    1,044

    Shameless plug. Sys is back..and so is his bravo...

    Shameless plug. Sys is back..and so is his bravo sierra.
  22. You'll need to pull some registers from the...

    You'll need to pull some registers from the Yaskawa. CAS Modbus Scanner from Chipkin is free, simple and just works. Simply Modbus is better if your experienced with modbus.
    I would bet it's a...
  23. You'll need to pull some registers from the...

    You'll need to pull some registers from the Yaskawa. CAS Modbus Scanner from Chipkin is free, simple and just works. Simply Modbus is better if your experienced with modbus.
    I would bet it's a...
  24. Thread: Max Masters

    by control$
    Replies
    29
    Views
    1,634

    Based on what I've seen using Lon FTT-10,...

    Based on what I've seen using Lon FTT-10, Arcnet/bacnet, and MS/TP bacnet. MS/TP gives the most options for iffy communication wiring. For example; I don't know how many times I needed to install a...
  25. Replies
    52
    Views
    3,384

    What control did you have an issue with? I can't...

    What control did you have an issue with? I can't think of one until your back to exec 4.