02-18-2009, 03:23 PM
Thread: Title 24 and roll-up doors
by Draper1- Replies
- 0
- Views
- 236
Title 24 and roll-up doors
Is there anything in the California Title 24 code which states how to handle large roll-up doors as far as the building envelope forms are concerned?
-
11-03-2008, 10:26 AM
Thread: 7.5 to 10 ton split systems w/ 410A
by Draper1- Replies
- 5
- Views
- 487
Thank you. R-22 is basically not allowed in...
Thank you. R-22 is basically not allowed in California, which is where the project is. They do allow R-22, but if the unit is inside the building, the amount allowed in the system is very low.
-
10-31-2008, 08:08 PM
Thread: 7.5 to 10 ton split systems w/ 410A
by Draper1- Replies
- 5
- Views
- 487
7.5 to 10 ton split systems w/ 410A
I need help finding a company with split system air conditioners using any of the newer refrigerants (not R-22), in the 7.5 to 10 ton range.
-
10-09-2008, 06:31 PM
Thread: Industrial warehouse ventilation
by Draper1- Replies
- 5
- Views
- 1,194
Actually, I already did.
Actually, I already did.
-
10-09-2008, 04:59 PM
Thread: Industrial warehouse ventilation
by Draper1- Replies
- 5
- Views
- 1,194
The point of the question was not to supply the...
The point of the question was not to supply the minimum per code, but to make the warehouse more comfortable for the occupants.
-
10-09-2008, 09:16 AM
Thread: split system capacity vs outside temp
by Draper1- Replies
- 12
- Views
- 581
I contacted Trane and had the rep just run the...
I contacted Trane and had the rep just run the program they have.
-
10-07-2008, 04:04 PM
Thread: redundancy in switchgear building
by Draper1- Replies
- 1
- Views
- 462
redundancy in switchgear building
I have a job in California, and need to know what the normal HVAC redundancy requirements are for low and medium switchgear buildings at a power plant. What is normal industry practice.
-
10-07-2008, 10:20 AM
Thread: economizer low limit
by Draper1- Replies
- 4
- Views
- 573
I'll answer my own question. At an outside air...
I'll answer my own question. At an outside air temperature of 55 degrees or lower, modulate dampers to maintain a supply air temperature of 55 degrees, for coolilng. For heating, drive outside damper...
-
10-07-2008, 09:53 AM
Thread: economizer low limit
by Draper1- Replies
- 4
- Views
- 573
Per the California Energy Code, the economizer...
Per the California Energy Code, the economizer should shut off, and minimum outdoor air should be used at 76 degrees OAT DB and above. The design heating temperature for the area is 30 degrees, and I...
-
10-07-2008, 09:27 AM
Thread: split system capacity vs outside temp
by Draper1- Replies
- 12
- Views
- 581
The all time record after 92 years of record...
The all time record after 92 years of record keeping is 87 degrees:
http://www.ncdc.noaa.gov/oa/climate/online/ccd/extrememax.html -
10-07-2008, 09:15 AM
Thread: economizer low limit
by Draper1- Replies
- 4
- Views
- 573
economizer low limit
What is the recommended temperature on the low end, to use the minimum quantity of outdoor air, when controlling with outdoor air dry bulb temperature?
-
09-26-2008, 05:33 PM
Thread: split system capacity vs outside temp
by Draper1- Replies
- 12
- Views
- 581
No one has answered the original question yet.
No one has answered the original question yet.
-
09-26-2008, 05:21 PM
Thread: split system capacity vs outside temp
by Draper1- Replies
- 12
- Views
- 581
Look in ASHRAE. It is 70, and the site I am...
Look in ASHRAE. It is 70, and the site I am designing for is less than 0.25 miles from the coast.
-
09-26-2008, 04:09 PM
Thread: split system capacity vs outside temp
by Draper1- Replies
- 12
- Views
- 581
Eureka, California. The main cooling load is the...
Eureka, California. The main cooling load is the equipment load in the building. 64 percent of the total cooling load is equipment and lighting load.
-
09-26-2008, 03:04 PM
Thread: split system capacity vs outside temp
by Draper1- Replies
- 12
- Views
- 581
split system capacity vs outside temp
How do the ratings of split system air conditioning systems vary from the published values of total and sensible capacity (which are generally published at ratings of 85 to 105 degrees F) if the...
-
07-31-2008, 06:24 PM
Thread: laundry, and galley air recirculated
by Draper1- Replies
- 0
- Views
- 268
laundry, and galley air recirculated
What air cleaners are available to clean air from galley, and laundry areas sufficiently to recirculate the air back to a centralized system?
-
07-24-2008, 12:05 PM
Thread: Carrier HAP and 100% OA units
by Draper1- Replies
- 1
- Views
- 579
I just answered my own question, which i should...
I just answered my own question, which i should not have asked. It is obvious in the program.
-
07-23-2008, 07:05 PM
Thread: Carrier HAP and 100% OA units
by Draper1- Replies
- 1
- Views
- 579
Carrier HAP and 100% OA units
How do you size a 100% OA unit using the Carrier HAP program?
-
07-22-2008, 04:28 PM
Thread: ridge vent velocity
by Draper1- Replies
- 0
- Views
- 339
ridge vent velocity
In a warehouse what would a typical ridge vent velocity range be?
-
R-422b
No problem really with the R-22 phase out. Just replace it with R-422B. Here is the info: http://www.icorinternational.com/nu22b.html
-
07-16-2008, 09:40 AM
Thread: Infiltration thru roll up door
by Draper1- Replies
- 6
- Views
- 1,305
The Carrier book was probabally the very first...
The Carrier book was probabally the very first book I bought when I was just starting.
-
07-15-2008, 07:21 PM
Thread: Infiltration thru roll up door
by Draper1- Replies
- 6
- Views
- 1,305
I also found a good answer in the Carrier...
I also found a good answer in the Carrier "Handbook of Air Conditioning System Design" on page 1-94, table 43c: It lists the values of infiltration to use for a shipping room door per square foot for...
-
07-15-2008, 03:48 PM
Thread: Infiltration thru roll up door
by Draper1- Replies
- 6
- Views
- 1,305
Infiltration thru roll up door
Does anyone have a good method of estimating the infiltration thru a loading dock roll up door?
-
07-13-2008, 01:56 PM
Thread: Industrial warehouse ventilation
by Draper1- Replies
- 5
- Views
- 1,194
Could someone please answer the question?
Could someone please answer the question?
-
07-11-2008, 06:21 PM
Thread: Industrial warehouse ventilation
by Draper1- Replies
- 5
- Views
- 1,194
Industrial warehouse ventilation
If you have an industrial warehouse, in a hot humid climate, and what is being stored is not sensitive to heat or humidity, then what air change rate would you use for ventilation? It is only to be...