    I think that's a heat pump so it should have one...

    I think that's a heat pump so it should have one already. You can't pipe accumulators in series.
  2. Replies
    4
    Views
    1,528

    if your buying that stuff at the auto part stores...

    if your buying that stuff at the auto part stores they do offer the drop in for r12 systems in the little jugs. youll just need some adaptors to get you from 1/2 inch acme to 1/4 flare so you can use...
  3. Replies
    4
    Views
    1,528

    I think they make a drop in replacement for 12 now

    I think they make a drop in replacement for 12 now
  4. Thread: Annex Air

    by ambarton
    Replies
    5
    Views
    1,681

    These are the bearings on the enthalpy and...

    These are the bearings on the enthalpy and sensible wheels. little dinky sealed for life bearings. our annexair units are in there second season of operation. they use hot and chill water decks to...
  5. Replies
    86
    Views
    4,888

    I did'nt think Carrier liked underground lines. I...

    I did'nt think Carrier liked underground lines. I have read many articles on this and listened to both sides of the argument. Some say CCH's work and some say they don't. Depending on the situation I...
  6. Thread: Annex Air

    by ambarton
    Replies
    5
    Views
    1,681

    Really? Did you mean carrier? Thats interesting...

    Really? Did you mean carrier? Thats interesting because we were told by Trane that they were their reps. Some more info on that would be nice
  7. Replies
    26
    Views
    2,071

    Some of those old GE units were bullet proof. I...

    Some of those old GE units were bullet proof. I can tell you where more than a couple dozen are still running while some other brands have come and gone more than once. if that were my unit and both...
  8. Replies
    9
    Views
    804

    See there Mr. Homeowner, go ahead and feel that...

    See there Mr. Homeowner, go ahead and feel that big line there. I got her really good and cold now. Did you say you had cash?
  9. Replies
    9
    Views
    804

    I never get tired of hearing that one. LOL

    I never get tired of hearing that one. LOL
  10. Hey boss, whats this here plastic hickey cover'n...

    Hey boss, whats this here plastic hickey cover'n up all them wire terminals? i don't know. uh hey boss, what!, what u want me to do with all this leftover wire? just tie it up somewheres dilbert?
  11. Replies
    9
    Views
    804

    Did you not get the memo? All u gotta do is grab...

    Did you not get the memo? All u gotta do is grab that big line there see and when she gets really good and cold well thats about right!:grin2:
  12. Replies
    9
    Views
    804

    yes. some manufacturers want you to do just that....

    yes. some manufacturers want you to do just that. open the suction valve to an evacuated lineset to boil off any liquid refrigerant in the compressor. york i think
  13. when did you have this put in. a ph10 is a ten...

    when did you have this put in. a ph10 is a ten seer unit?? am i missing something/
  14. Replies
    17
    Views
    2,581

    a lot of folks here in the south like to set the...

    a lot of folks here in the south like to set the defrost intervals on the max. i disagree with that because we see a lot of 30something degree rain which is hard on a heat pump. maby they need to...
  15. Replies
    15
    Views
    2,393

    If you feel that your capable of changeing the...

    If you feel that your capable of changeing the motor yourself, go to a local hvac company and buy the motor. and afterwards for good measure schedule a inspection of your system i dont have a...
  16. Thread: Annex Air

    by ambarton
    Replies
    3
    Views
    995

    Thanks it has been a while since i have visited...

    Thanks it has been a while since i have visited this website and a lot has changed. I have applied for (*) Sorry for the harshness, Andrew
  17. Replies
    19
    Views
    1,359

    what was it during heating between acc and comp?...

    what was it during heating between acc and comp? (superheat)
  18. Replies
    19
    Views
    1,359

    it mite be a ***** but try reading superheat...

    it mite be a ***** but try reading superheat between accumulator and compressor. that mite tell you if your flooding or not
  19. Replies
    19
    Views
    1,359

    that makes sense but only if your running in ac...

    that makes sense but only if your running in ac mode. rember a hp is sending hot gas to the air handler and converting to a liquid so any oil in the hot gas becomes mixed with the liquid and gets...
  20. Replies
    1
    Views
    466

    70 degree water wow!

    70 degree water wow!
  21. Replies
    19
    Views
    1,359

    That is only when the evaporator is below the...

    That is only when the evaporator is below the compressor and strictly for cooling only. where did they suggest putting the trap?
  22. Replies
    19
    Views
    1,359

    where do they want you to put the inverted trap...

    where do they want you to put the inverted trap on a heat pump?
  23. a sheet of ice? where u cooling with it when...

    a sheet of ice? where u cooling with it when that happened? you can get a unit with a better seer rating but finding a contractor that can install it and keep that rating may be harder and you mite...
  24. Replies
    38
    Views
    7,846

    what u take for the whole lot?

    what u take for the whole lot?
  25. Replies
    11
    Views
    922

    i have seen this in older apartments in the south...

    i have seen this in older apartments in the south from the 60's. good when power was cheap and most people never had air conditioning before. bad in todays market. what is that rusty pipe thing...
  26. just curious what size air handlers are you...

    just curious what size air handlers are you using? i think beenthere already asked this question but i did not see a reply
  27. not going to be a stuck service valve. can u...

    not going to be a stuck service valve. can u pass N2 through the system with the controls calling and outside unit disabled?
  28. so you have 2 air handlers on a 5 ton unit and...

    so you have 2 air handlers on a 5 ton unit and only one can run at a time and you have 2 solenoid valves one for each air handler? are the valves normally open or closed and are u doing a pumpdown...
  29. dont have a pt chart in front of me but if...

    dont have a pt chart in front of me but if saturated pressure temps were say 200 and it is tripping on low pressure of say 100 i think your comp is pumping just fine after only 4 seconds of running....
  30. Replies
    26
    Views
    1,770

    im sorry it just burns my beans sometimes when...

    im sorry it just burns my beans sometimes when people question those who are supposed to know.
  31. where u hookin your guages up?

    where u hookin your guages up?
  32. Replies
    26
    Views
    1,770

    what ru going to test what i mean is do you know...

    what ru going to test what i mean is do you know anything about ac units other than if i turn the thermostat way down it will cool much faster! go on turn it on heck it will be a better test if u...
  33. Replies
    17
    Views
    935

    100,000k furnace/1000=100 cubic feet of gas price...

    100,000k furnace/1000=100 cubic feet of gas price of a cubic foot of gas times 100 gives answer 1.44/100=.0144x100=1.44 per hour of use
  34. Replies
    20
    Views
    1,768

    yes but most times elec compnys want volunteer...

    yes but most times elec compnys want volunteer the lower rates offered by being total elec they make u ask for them
  35. Replies
    20
    Views
    1,768

    slip a brochure of an assisted living community...

    slip a brochure of an assisted living community in your mail box and thed ask mother in law to go check the mail shell stop complaining and that power bill dont sound too bad for 40 days like the...
  36. Replies
    17
    Views
    935

    divide 1.44229 by 100 that is the cost per cubic...

    divide 1.44229 by 100 that is the cost per cubic foot of gas. a cubic foot of gas has about 1000 btu's. take the input of your furnace and divide by 1000 take that answer and multiply by the cost...
  37. Replies
    45
    Views
    2,018

    it could be done but most people would call him a...

    it could be done but most people would call him a hack. why not just spend the extra bucks and get it done with a new unit. mite be more efficient. if your strapped for cash but can afford it in...
  38. Replies
    4
    Views
    5,663

    yeah me too. here in the south you hear...

    yeah me too. here in the south you hear everything for everyday home remedies. born and raised in the south and never heard that one.
  39. Replies
    7
    Views
    1,124

    are these r410a units? they must be with 600 lb....

    are these r410a units? they must be with 600 lb. head pressure. what is that temp @ 600lbs.?
  40. Replies
    30
    Views
    2,809

    agreed! do you not like your carrier unit or is...

    agreed! do you not like your carrier unit or is this all that is offered in your area. lennox and amana are owned by the same company. get a carrier quote. they too have efficient quiet units
  41. Replies
    7
    Views
    1,124

    most units are based on a charge with 15' lineset...

    most units are based on a charge with 15' lineset and matching indoor coil. im not sure what u mean with the head pressure affecting the txv's?
  42. Replies
    4
    Views
    5,663

    table salt as a chimney cleaner?

    table salt poured onto a burning fire can help keep a chimney clean (wood burning)? true or false chemistry proven answers only!!
  43. Replies
    15
    Views
    4,316

    did you have a heat pump or gas before the...

    did you have a heat pump or gas before the install?
  44. Replies
    27
    Views
    2,624

    20kW where do u live? Big heat pump? seldome see...

    20kW where do u live? Big heat pump? seldome see a 20 on resid. units in the south anymore but plenty on older units.
  45. Replies
    18
    Views
    1,356

    maby they changed there mind about furnace...

    maby they changed there mind about furnace selection. gas fueled equip. requires fresh air for combustion in most areas for code requirements. if that is a fire wall shared by another apartment...
  46. Replies
    4
    Views
    658

    i would expect a slight temp diff suddenly at...

    i would expect a slight temp diff suddenly at start-up and the temp being the actual temp of the liquid line. yours sounds OK
  47. Replies
    4
    Views
    658

    exactly! this is one of the easiest ways to...

    exactly! this is one of the easiest ways to detect a restricted filter is at startup. the sudden pressure diff. at start up tells u the condition of the filter. if the temp settles down it will...
  48. Replies
    20
    Views
    2,963

    lets take all suggestions into account. if your...

    lets take all suggestions into account. if your ducts are too small your indoor unit is not going to be moving enough air across the coil (indoor) and possibly not condensing the refrigerant. now...
  49. Replies
    875
    Views
    103,696

    to help u understand i need more info like your...

    to help u understand i need more info like your location and if it is a horizontal loop or a verticle loop system. 32 in is pretty cold mite as well have a standard air to air system
  50. Replies
    875
    Views
    103,696

    sounds like u have a bum geo system

    sounds like u have a bum geo system