Search:

Type: Posts; User: dav214

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    126

    quoting hvac maintance

    hay guys

    For quoting maintance on hvac equipment , is the best way to go to site or is there a program to use? any advice would be great

    thanks for any help
  2. Replies
    13
    Views
    831

    Checked the reversing valve , is switching ...

    Checked the reversing valve , is switching


    Sent from my iPhone using Tapatalk
  3. Replies
    13
    Views
    831

    Just like a thump Sent from my iPhone using...

    Just like a thump


    Sent from my iPhone using Tapatalk
  4. Replies
    13
    Views
    831

    normal amp draw while running

    normal amp draw while running
  5. Replies
    13
    Views
    831

    The noise is when the compressor stops Sent...

    The noise is when the compressor stops


    Sent from my iPhone using Tapatalk
  6. Replies
    13
    Views
    831

    Yes , iam a tech Sent from my iPhone using...

    Yes , iam a tech


    Sent from my iPhone using Tapatalk
  7. Replies
    13
    Views
    831

    Customers Sent from my iPhone using Tapatalk

    Customers


    Sent from my iPhone using Tapatalk
  8. Replies
    13
    Views
    831

    muffler on heat pump

    have a 4 year heat pump very noisey, thinking muffler is no good, running well but for the noise

    any recommendations?
  9. Replies
    0
    Views
    232

    hrv not connected to return

    question

    walk into a house today and noticed the supply from the hrv was not connected to return duct, the supply pipe was 6 " away open and there was a hole in the return, customer called other...
  10. Thread: bypass damper

    by dav214
    Replies
    1
    Views
    339

    bypass damper

    how would I go about setting a bypass damper on zoned system?
  11. Replies
    4
    Views
    364

    thanku

    thanku
  12. Replies
    4
    Views
    364

    semihermetic compressor

    should oil be changed in semi-hermetic compressor every couple of years or just if discoloured or the valves need to be redone

    thanks
  13. Thread: contact cleaner

    by dav214
    Replies
    1
    Views
    252

    contact cleaner

    contact cleaner , just for use on contactors or can been used elsewhere?


    thanks
  14. Thread: gauges?

    by dav214
    Replies
    1
    Views
    376

    gauges?

    is a water or air gauge the same as a refrigeration gauge, if not why not

    thanks
  15. Thread: condenser

    by dav214
    Replies
    2
    Views
    446

    condenser

    hey guys

    what is a molecular condenser
  16. Thread: pump back

    by dav214
    Replies
    14
    Views
    1,018

    thank u

    thank u
  17. Thread: accumulators

    by dav214
    Replies
    3
    Views
    336

    accumulators

    Hey guys
    does all accumulators have fusiable plugs

    thanku
  18. Thread: pump back

    by dav214
    Replies
    14
    Views
    1,018

    pump back

    why and what circumstances would u want to pumpback the refrigerate into the condenser in refrigeration
  19. Thread: humidifers?

    by dav214
    Replies
    2
    Views
    262

    humidifers?

    is there any good steam humidifier with out having to install water filter system and not cost over $, any recomendations
  20. Replies
    9
    Views
    838

    compressor sweating

    is it normal for the compressor to sweat?
  21. Thread: bullet

    by dav214
    Replies
    9
    Views
    577

    gauges not connected

    gauges not connected
  22. Thread: bullet

    by dav214
    Replies
    9
    Views
    577

    bullet

    bullet vacuum pump spits out a little bit of oil on startup, is that normal?
  23. Thread: bullet

    by dav214
    Replies
    5
    Views
    418

    bullet

    bullet vacuum pump spits out a little bit of oil on startup, is that normal?
  24. Thread: reclaimer

    by dav214
    Replies
    5
    Views
    396

    reclaimer

    do u guys put filter dryer on inlet of reclaimers all the time and how often to change?
  25. Replies
    7
    Views
    454

    garden hose and acid or pressure wash

    hey guys me again,

    just wondering to clean condenser coils , do most of u use pressure washer or just a good acid and a garden hose

    thanks
  26. Replies
    13
    Views
    819

    thanks guys

    thanks guys
  27. Thread: hoses

    by dav214
    Replies
    11
    Views
    635

    hoses

    do u guys recommending replacing hoses yearly or when broken or rebuild if u can?
  28. ecobee or nest or honeywell or lennox smart stats

    which is best smart stat in your opinon and why?
  29. Replies
    13
    Views
    819

    mixing gauges with refrigerates

    hey guys

    does it matter if I use r22 gauges with 134A, 500 series?.
    400 series refrigerate I have one gauges for those,i know these should be seperate
  30. Thread: different sizes

    by dav214
    Replies
    1
    Views
    295

    different sizes

    whats up with different size scrader valves,is there any reasoning behind that?
  31. Replies
    11
    Views
    1,123

    Micro channel condenser coil Sent from my...

    Micro channel condenser coil



    Sent from my iPhone using Tapatalk - now Free
  32. Replies
    11
    Views
    1,123

    Contactot good, amp good Sent from my iPhone...

    Contactot good, amp good


    Sent from my iPhone using Tapatalk - now Free
  33. Replies
    11
    Views
    1,123

    7.5,2 stage,2 fans ,fans on with y1 Sent...

    7.5,2 stage,2 fans ,fans on with y1


    Sent from my iPhone using Tapatalk - now Free
  34. Replies
    11
    Views
    1,123

    Pressure are fine and does not trip when I m...

    Pressure are fine and does not trip when I m there


    Sent from my iPhone using Tapatalk - now Free
  35. Replies
    11
    Views
    1,123

    lennox kGA rooftop?

    Lennox KGA rooftop unit keeps tripping manual high pressure switch on stage 1? anyone similar problem?
  36. Replies
    3
    Views
    489

    liquid temp 60 f

    I heard another tech say liquid temp is always 90 F for ac and 60 F refrigeration, is that just rule of thumb?
  37. Replies
    21
    Views
    1,319

    heating refrigerate tanks to remove rest

    Is a electric heat gun acceptable method of heating refrigerate tank to extract remaining refrigerate good method or what is best, tired of warm water
  38. Replies
    3
    Views
    419

    rotary vane compressor

    is there any way to identify a rotary vane compressor from scrolls
  39. Thread: r22

    by dav214
    Replies
    3
    Views
    442

    r22

    can I use r22 gauges with r134a,r12,r502
  40. Replies
    1
    Views
    319

    site user profile

    can t figure out where to fill out site user profile,i go into my profile won t let me fill anything out.Any ideas?
  41. Thread: grease

    by dav214
    Replies
    4
    Views
    565

    grease

    should I be greasing o rings in my gauges regularly?
  42. Thread: hoses

    by dav214
    Replies
    3
    Views
    418

    hoses

    whats the difference between black and coloured refrigerate hoses?
  43. Thread: dx coil?

    by dav214
    Replies
    3
    Views
    386

    dx coil?

    is dx coil another word for evaporator coil?
  44. Thread: inverted trap

    by dav214
    Replies
    2
    Views
    569

    inverted trap

    when and where do I use inverted traps?
  45. Thread: not sure

    by dav214
    Replies
    3
    Views
    384

    not sure

    should my motor/compressor be drawing rla or fla?
  46. Thread: rla and fla?

    by dav214
    Replies
    3
    Views
    486

    rla and fla?

    whats the difference?
  47. Thread: maytag

    by dav214
    Replies
    2
    Views
    415

    maytag

    any opinions on maytag furnace and ac?
  48. Replies
    3
    Views
    917

    24 volt transformer

    why sometimes on 24 volt transformer com goes to ground and sometimes does not
  49. Thread: oxy/acet

    by dav214
    Replies
    32
    Views
    2,383

    thankyou

    thankyou
  50. Thread: oxy/acet

    by dav214
    Replies
    32
    Views
    2,383

    oxy/acet

    for brazing copper with oxy/acet, do I wear cutting torch goggles or clear safety glasses ok
Results 1 to 50 of 57
Page 1 of 2 1 2