Search:

Type: Posts; User: pete_d

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    15
    Views
    6,411

    Please kindly email me your contact info. Thanks

    Please kindly email me your contact info.
    Thanks
  2. Replies
    5
    Views
    1,150

    b-man Could you please email me too? Thanks...

    b-man
    Could you please email me too?
    Thanks
    Pete
  3. Replies
    15
    Views
    6,411

    mtnwrench, How much does it cost you for this...

    mtnwrench, How much does it cost you for this software?
    Thanks
  4. Carrier (Franch) 30HG 320 901EE Wiring Diagram and Spare part list

    Please help me.

    I want the wiring diagram and spare part list manual of Carrier (France) 30HG 320 901--EE.

    Its nameplate is attached.

    Thank you in advance
  5. Replies
    0
    Views
    315

    19XR CVC Software CESR-131158-04

    Please help me for 19XR CVC Software CESR-131158-04.

    Thank you in advance.
  6. Replies
    1
    Views
    1,003

    TRANE CGAE Manuals wanted

    Hi everyone
    I want these manuals:-
    CGAE-IN-3 Cold Generators Air-Cooled
    CGAE-M-3 Air Cooled Cold Generators
    CGAE-W-2 Wiring Manual
    CON-AM-24

    Please kindly email me. My email is in my...
  7. Replies
    7
    Views
    2,479

    You can replace the dynaview (with correct MP...

    You can replace the dynaview (with correct MP software) from its twin to see the result.

    If you do not know how to download MP software properly, it is DANGEROUS to your machine.
  8. Thread: Carrier 19XR

    by pete_d
    Replies
    4
    Views
    1,022

    The float valve is stuck.

    The float valve is stuck.
  9. Replies
    7
    Views
    2,479

    There are 2 possible causes:- 1. Touch Screen...

    There are 2 possible causes:-
    1. Touch Screen sensor of Dynaview fails to provide correct position.
    2. The MP software of Dynaview is corrupted.

    I would recommend to download a new MP software...
  10. What major cause for CHHC Compressor motor burnout

    What are the major causes for TRANE CHHC Screw Compressor motor burnout?
  11. Replies
    7
    Views
    1,181

    Can I have sb0041 to study? Thank you

    Can I have sb0041 to study?

    Thank you
  12. 19XL High Discharge Temp intermittent alarm at compressor start

    The carrier chiller model 19XL5353304CR S/N 1994Jxxxxxx has an intermittent alarm.

    The alarm message in alarm history is
    'CMPD 221.0 F exceeds limit of 220.0 F, Check Discharge Temperature'.
    ...
  13. Replies
    11
    Views
    1,418

    High Discharge Temp Trip

    I work on one 19DR machine that has High Discharge Temperature trip.

    We ran it for 2 hours and have the following data.
    The oil temp is 140-145F. The suction superheat is about 4F.
    The measured...
  14. Replies
    3
    Views
    1,105

    The left side of Digital I/O Board is called...

    The left side of Digital I/O Board is called Digital Input (DI) Lines and Right Side called Digital Output (DO) Lines.
    The Control Point (CP) is the software program that drives one or more Digital...
  15. York 450.20-NOM1 Microgateway Installation and Operation Wanted

    Please! email me York form 450.20-NOM1 and BACnet Microgateway Operation Manual (450.20-??).

    Thanks
    No email addresses in post




    Please read site rules, Thank you.
  16. Replies
    3
    Views
    817

    TRANE CTV-SB-48 Needed

    Can your guy email me TRANE CTV-SB-48?
    Thanks in advance
    pete@pvt-worldwide.com
  17. Replies
    7
    Views
    2,351

    It is York YT 300 Tons chiller. There is no tube...

    It is York YT 300 Tons chiller. There is no tube leak. The tube sheet leak are at both ends. Is it recommended to do tubes eddy current test? What is the estimated cost?

    Thanks;
  18. Replies
    7
    Views
    2,351

    Repairing water cooled condenser tube sheet

    We found the leak at water cooled condenser tube sheet nut tubes.
    The water inlet pressure is 70 psig. The chiller refrigerant is R123.

    What do your guy do to repair this kind of leak at tube...
  19. Replies
    8
    Views
    1,811

    I think so. Check your email.

    I think so.
    Check your email.
  20. Replies
    16
    Views
    5,489

    Djken, Can I have your email address? Removed...

    Djken, Can I have your email address? Removed email




    Please put email in your profile!
  21. Thread: York Chiller

    by pete_d
    Replies
    1
    Views
    561

    Check your email.

    Check your email.
  22. Replies
    1
    Views
    554

    YK Wiring Diagram 160.54-PW2.1

    For those who have it, please kindly email me. My email is in my profile.
    Thanks
  23. Replies
    8
    Views
    1,390

    Please send me an e-mail. My e-mail address is...

    Please send me an e-mail.
    My e-mail address is in my profile.
  24. Thread: York Oil

    by pete_d
    Replies
    23
    Views
    8,353

    YORK "L" is ISO 120 POE Oil used with DXS Screw...

    YORK "L" is ISO 120 POE Oil used with DXS Screw Compressor on YCWS/YCAS Chiller.
  25. Replies
    2
    Views
    927

    If blank screen means dark, check the cable from...

    If blank screen means dark, check the cable from Micro Board to Inverter Board next to the Display or the display lamp is poor.
Results 1 to 25 of 78
Page 1 of 4 1 2 3 4