  1. Whole house ventilation and dehumidifier

    At 400 cfm +\- and depending on the footprint, I would run (2) oversized ducts up and (2) oversized ducts down which will allow you manual control to close a particular floor if needed. Return each...
  2. Replies
    2
    Views
    222

    The question comes down to what is wrong with the...

    The question comes down to what is wrong with the ac? Ice ball typically is an airflow issue or a leak in the refrigeration system. If the system is leaking at that age, IMO you are best to look at...
  3. Replies
    10
    Views
    460

    I had 2 of mine break and a few other guys had...

    I had 2 of mine break and a few other guys had the same a couple yrs ago. The replacements seem to hold up better. And the "call me" was suppose to be "call em" :)


    Sent from my iPhone using...
  4. Replies
    10
    Views
    460

    They do that,, been told it was a "bad batch" and...

    They do that,, been told it was a "bad batch" and the plastic has changed. Call me and they will send ya new ones


    Sent from my iPhone using Tapatalk
  5. Replies
    16
    Views
    1,600

    Not me,,, like dating a woman that has been...

    Not me,,, like dating a woman that has been around the block too many times.


    Sent from my iPhone using Tapatalk
  6. Replies
    29
    Views
    1,178

    Venting a Gas Furnace

    Another option would be to (2) pipe the furnace up the abandoned chimney chase allowing for a 2 pipe system and installing an electric water heater to replace the gas one. Using electric to heat...
  7. Condensing boilers with single pipe vs two pipe loops

    Without replacing or adding a large amount of additional radiation you have a condensing boiler that will not condense in most situations. Your best chance is having an outdoor reset control...
  8. Replies
    4
    Views
    250

    Maybe the liner is kinked/plugged and the unit is...

    Maybe the liner is kinked/plugged and the unit is not venting properly and condensing? Maybe the gas pressure/rise is off? Maybe the connector in inadequate? Perhaps the termination is too short?
  9. Replies
    17
    Views
    753

    Propane line from tank

    I deal with this quite often. The propane supplier will provide us with a regulator at the entrance of the home Outside, we take it from there. In my experience they instal the piping wicked cheap....
  10. Replies
    0
    Views
    195

    Jb dv200 vac pump issue

    Anyone ever have the ballast knob break on a pump? I have never seen this and I had 2 guys break the bolt part internal in the threading this week. Both pumps less than 2yrs old. At first I thought...
  11. Replies
    26
    Views
    2,947

    I sliced my tendons on 2 fingers on rheem 80%...

    I sliced my tendons on 2 fingers on rheem 80% about 12yrs ago. I was in a cast for 4 weeks Rheem could care less. The bottom blower door edge. Another guy I worked with is almost the identical thing...
  12. Replies
    1
    Views
    263

    Looking up the specs, it says "do not install in...

    Looking up the specs, it says "do not install in location that is hot or humid for long periods of time".
  13. The condensate pump is used when you do not have...

    The condensate pump is used when you do not have a gravity drain meaning that you cannot go down maintaining pitch. The example you describe would be a wall unit installed on an interior wall with...
  14. Replies
    9
    Views
    457

    I wouldn't worry about the bent line. It is not...

    I wouldn't worry about the bent line. It is not going to effect operation of any measurable difference. Kinda looks Undesirable as the unit is not centered on the pad.
  15. Replies
    18
    Views
    2,082

    Look at all the white cellulose

    Look at all the white cellulose
  16. Replies
    14
    Views
    1,006

    Well the 460 is out. Doesn't seem to be much info...

    Well the 460 is out. Doesn't seem to be much info regarding wireless or future app compatibility??? It isn't listed on the fieldpiece site. Ttt and others have them. I'll stay tuned I suppose
  17. Your contractor can hook you up. ...

    Your contractor can hook you up.

    https://www.taco-hvac.com/archives/100-3.4G.pdf
  18. Some like ford, some like Chevy. I personally...

    Some like ford, some like Chevy. I personally like the taco as they have a vacuum breaker installed.
  19. Converting from oil to gas. Furnace is dead. House has hybrid Steam and FA sy...

    Mitsubishi hyperheat mini split. I am in ny and they will keep up just fine into the negative digits.
    As for valves... You do not want valves what go on the steam piping entering the radiator, we...
  20. Converting from oil to gas. Furnace is dead. House has hybrid Steam and FA sy...

    Piping looks descent. I wish the vertical rise out of the top of the boiler was larger but it is what it is. Insulate those pipes!! All piping above the water level should be insulated with...
  21. Replies
    10
    Views
    455

    If you have the equipment,, find a contractor to...

    If you have the equipment,, find a contractor to install it properly for you. Many will not touch it but some will. Most will want to get markup to cover the overheads which is fair. It will be less...
  22. 90% forced air furnace and convert the oil boiler...

    90% forced air furnace and convert the oil boiler to gas. It is a wet base boiler and an easy conversion. Replacing the steam boiler will gain you very very little in efficiency savings. I Of...
  23. Replies
    11
    Views
    1,862

    Tell em it needs to be 4' from the regulator and...

    Tell em it needs to be 4' from the regulator and it's a 2fer
  24. Replies
    46
    Views
    2,501

    Fieldpiece service is the best. I would think it...

    Fieldpiece service is the best. I would think it would be pretty easy to make them highly water resistant. If the k tcouples were moved to the bottom it would create a drip loop and a plastic...
  25. Is this going to be the platform for the app? I...

    Is this going to be the platform for the app? I would imagine the teaser app is still in process?