  1. Replies
    15
    Views
    721

    Plenty of small stores and restaurants out there...

    Plenty of small stores and restaurants out there with refrigeration condensing units in the basement.
  2. Replies
    48
    Views
    1,096

    Is the condensing unit indoors or outdoors? If...

    Is the condensing unit indoors or outdoors? If indoors, follow icemeister's advice.
  3. Replies
    15
    Views
    721

    Are the evap and condenser in the same space? If...

    Are the evap and condenser in the same space? If not, and the bedroom is 3000sq ft it should work just fine.
  4. Thread: subcooling

    by stat
    Replies
    74
    Views
    1,926

    In other words, excessive subcooling makes the...

    In other words, excessive subcooling makes the TXV oversized.
  5. Replies
    48
    Views
    1,096

    Add a second receiver in series with the first. ...

    Add a second receiver in series with the first. Receivers are cheap. Cost about the same as the suction stop and you don't have to change how the system operates.
  6. Replies
    7
    Views
    554

    My reply to a similar query "The day I can...

    My reply to a similar query

    "The day I can see the future is the day I stop carrying tools for a living."
  7. Replies
    25
    Views
    1,011

    x2 The AC compressor in the store I service has...

    x2
    The AC compressor in the store I service has been out for two years..
  8. Kwik Trip?

    Kwik Trip?
  9. Replies
    41
    Views
    2,645

    There are three roof heights and two wheel bases....

    There are three roof heights and two wheel bases. The picture is of the standard height. I am interested in the medium height long wheel base which I believe is approximately 5'10" inside. Three...
  10. Replies
    41
    Views
    2,645

    Yes. I think it is what I want next. I want to...

    Yes. I think it is what I want next. I want to see one in person.
  11. Replies
    6
    Views
    397

    5%, 45% and staybrite

    5%, 45% and staybrite
  12. Replies
    71
    Views
    1,749

    So now you have a cap tube system with a receiver...

    So now you have a cap tube system with a receiver ?
  13. Replies
    71
    Views
    1,749

    Isn't that second condenser completely full of...

    Isn't that second condenser completely full of liquid?
  14. I just bought MB2 bag to use for trouble...

    I just bought MB2 bag to use for trouble shooting. I was wishing it was a little bigger.
  15. Replies
    29
    Views
    1,385

    In my jurisdiction the fire inspector will shut...

    In my jurisdiction the fire inspector will shut down a kitchen if the exhaust fans are found not to be working. The exhaust fans need to be running in case of fire. He will also require any cooking...
  16. Replies
    71
    Views
    1,749

    Condensing unit R404 TXV/receiver ETC ...

    Condensing unit
    R404
    TXV/receiver
    ETC

    Everybody wins
  17. Replies
    11
    Views
    704

    Suction line icing back on a freezer means...

    Suction line icing back on a freezer means nothing. On most of my systems ice on the suction line means everything is working properly. Make sure the evap is ice free, the box is close to temp and...
  18. Thread: Age old debate

    by stat
    Replies
    22
    Views
    1,204

    Been using Stay Brite for 25 years, including R22...

    Been using Stay Brite for 25 years, including R22 medium temp discharge lines. Never had an issue.
  19. Replies
    77
    Views
    4,833

    Around here the service dept of the restaurant...

    Around here the service dept of the restaurant supply company tells the customer it can't be fixed and the unit needs to be replaced.

    Actually, they do that to all equipment they look at. Keeps...
  20. Replies
    32
    Views
    1,549

    Just like the CPR, the pressure limiting TXV...

    Just like the CPR, the pressure limiting TXV prevents the compressor from excessive suction pressure, not flooding. Using the pressure limiting TXV saves you the cost of buying a CPR valve. This...
  21. Replies
    32
    Views
    1,549

    Never installed a condensing unit with an...

    Never installed a condensing unit with an accumulator in 25yrs, including the two low temps I put in last week. I have however seen systems with accumulators still flood compressors.

    Use a...
  22. Replies
    77
    Views
    4,833

    Anything made by Cold-Tech

    Anything made by Cold-Tech
  23. I trap the cooler at the coil, trap the freezer...

    I trap the cooler at the coil, trap the freezer line inside the cooler then tee into the common line
  24. Replies
    8
    Views
    17,276

    Make sure the cut in pressure saturated suction...

    Make sure the cut in pressure saturated suction temperature is below the coldest ambient temperature. Around here on R22 I use 8lbs CI and 2lbs CO. This will keep it running when it is -20F.
  25. Replies
    22
    Views
    1,653

    Screen roller tool