Search:

Type: Posts; User: SkyHeating

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. We use a temporary metal floor register since...

    We use a temporary metal floor register since many builders in our area will still run the furnace during construction. The metal floor register has much smaller holes than a normal floor register...
  2. Sorry I didn't see your post until now, the XV18...

    Sorry I didn't see your post until now, the XV18 and XV20i are the same noise, the reason the youtube video may sound different is that the XV20i may be running at 30% capacity and the XV18 is...
  3. Current house, nothing extra, just a working mid...

    Current house, nothing extra, just a working mid efficiency heat pump, two stage 95% gas furnace, HRV and tankless water heater.

    New house will have variable capacity geothermal with geothermal...
  4. Ah, my mistake, it is legal to manufacture until...

    Ah, my mistake, it is legal to manufacture until 2020 but in restricted amounts, but air conditioners can no longer be shipped with it, I was mixed up on the two since we have not sold R22 AC's for...
  5. Coils can be hard to find and often they are not...

    Coils can be hard to find and often they are not available, R22 refrigerant is now illegal to manufacture but is still readily available, you may have misheard what they told you but nothing seems to...
  6. Replies
    12
    Views
    1,229

    Apprentice, please e-mail me your resume if you...

    Apprentice, please e-mail me your resume if you are looking for work or have any friends that are looking for work.
  7. Largest geothermal manufacture is kinda like...

    Largest geothermal manufacture is kinda like saying the the largest toaster manufacture won't connect to my system. The reason I say this is that geothermal in the united states is maybe 1% of the...
  8. The 7 Series will only connect to the web with...

    The 7 Series will only connect to the web with the AWL which is not even out yet for beta testing... As I am on the first list to get one.

    I still highly doubt the AWL will connect to your...
  9. I will get this for you when i get back to my...

    I will get this for you when i get back to my computer at work, we install a ton of these and in my area we are required to hook up the sensor for rebates.
    The remote indoor sensor is if you want to...
  10. Replies
    12
    Views
    519

    As far as I know Trane was the last to offer a...

    As far as I know Trane was the last to offer a factory, non 3rd party warranty but that stopped May of last year, I now do an in house warranty since the national companies are overpriced, rarely...
  11. Replies
    9
    Views
    692

    There is no priority, you just need to make sure...

    There is no priority, you just need to make sure the loop can flow for all units
    Lets say you have a 2 ton that needs 6 GPM and then a 3 ton that needs 9 GPM, that just means your loop must flow 15...
  12. Replies
    9
    Views
    692

    No, you can do as many units as your pumps can...

    No, you can do as many units as your pumps can handle and the BTU's your loop is designed for. I have a 7500 sq foot home with 4 geo systems on one loop. Two for water heating and two for air.
  13. Seriously, I would LOVE for you to show me where...

    Seriously, I would LOVE for you to show me where you can purchase an XC80 online because i have never found one. Trane is probably one of the best at ensuring their equipment does not make it online....
  14. Not really correct information. The XC80 is a...

    Not really correct information. The XC80 is a better ratings match with some AC and heat pump systems and the TCONT 803 is a good thermostat match for it. While the XC80 works best with a...
  15. Replies
    9
    Views
    692

    The other option is to still do the 4 ton dual...

    The other option is to still do the 4 ton dual stage but add a dehumidier to the house to help control the humidity during the AC season yet provide 95% of the heat in the heating season.
  16. Replies
    9
    Views
    692

    So is the 53,000 BTU per hour for the whole home...

    So is the 53,000 BTU per hour for the whole home or is that part of the garage and basement. Or is it that the garage and basement are an additional 35K BTU per hour.
    First I would put in a two...
  17. Replies
    9
    Views
    584

    Woah, they installed it without authorization or...

    Woah, they installed it without authorization or anybody being home? I would tell them to come pick up their unit and then get the heck off your property, this seems VERY shady or you are not telling...
  18. Replies
    4
    Views
    269

    For a block load people are going to need to...

    For a block load people are going to need to know. Length and height of all walls and what direction they are facing and how much insulation is in them, then the sq footage of windows on that wall....
  19. Garrett, i had a chance to look over the...

    Garrett, i had a chance to look over the proposals that Greg provided for you, after talking to him it sounds like the ductless really is the way to go. He did not look at the ducts because he was...
  20. In our Portland Climate dehumidifiers are fairly...

    In our Portland Climate dehumidifiers are fairly rare, but there are a few options that could be looked at. Honeywell and Aprilaire both make good units specifically for this reason but can be spendy...
  21. I will have to talk to my system designer that...

    I will have to talk to my system designer that came out to see what their consensus was but if we are doing ductless then looking at the ductwork isn't going to add much since they will be abandoned....
  22. Replies
    12
    Views
    1,229

    Living in Oregon is not to cheap, but we also pay...

    Living in Oregon is not to cheap, but we also pay much more than $20 for a top tech, our best guys made $60K last year. $20 would be for a retro installer with minimal experience or a top new...
  23. The variable speed trilogy is very new, i think...

    The variable speed trilogy is very new, i think it has only been available for a month or two so who knows how good it is. I do know that climatemaster inflated their ratings to make it "look" like...
  24. A trilogy 30 or? The Trilogy 30 is not even in...

    A trilogy 30 or? The Trilogy 30 is not even in the same class as the 7 Series/Sycamore.
  25. Geostar Sycamore is made at the WaterFurnace...

    Geostar Sycamore is made at the WaterFurnace factory and is identical as far as I can tell. The area where you have differences is in the number of dealers and tech/warranty support. WaterFurnace...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4