  1. It is a Ducane model 92G1UH. ...

    It is a Ducane model 92G1UH.
    http://www.proheating.com/resources/a951install.pdf
    The only restrictions I see is no closer than 12" to the underside of the deck.
    I don't disagree that venting...
  2. I just talked to a Ducane tech and he says it's...

    I just talked to a Ducane tech and he says it's not a problem.
  3. Yes and yes. The top vent is for a WH.

    Yes and yes. The top vent is for a WH.
  4. Cat IV Wall Termination-2 pipe installed vertically

    The direct vent requirements for this furnace call for the two pipes to be installed horizontally. What are the practical concerns with this set up of the pipes being installed vertically?
    504711
  5. Replies
    7
    Views
    640

    White Pleated or Blue Furnace Filter

    Is it a myth that white pleated filters are bad for your furnace because they restrict too much airflow? I have heard this too many times so I thought I would ask.
  6. Replies
    2
    Views
    294

    "Does the exhaust "90" down so it isn't subject...

    "Does the exhaust "90" down so it isn't subject to massive rain influx ?" No. But it is immediately beneath a deck which is just another issue in a long list of installation problems.

    And...
  7. Replies
    2
    Views
    294

    Exhaust-Combustion Air Vents Separated

    I inspected a 3 story condo. The 2nd floor unit has a 10 year old Cat 4 direct vent Tappen FG6RC. The exhaust vents horizontally out an exterior wall and the combustion air supply pipe goes up...
  8. Replies
    0
    Views
    315

    Interior Winter Moisture

    I am helping a client look into excessive interior moisture on windows in winter. This is Chicago new 1-2 yr old construction. It is likely an energy tight 2 condo building. She has gotten...
  9. Replies
    10
    Views
    871

    An American Standard tech sent me the pdf. for...

    An American Standard tech sent me the pdf. for what he thought was the correct installation instructions. I guess I had the model # wrong. The instructions are vague.

    The Rheem pdf from Mason is...
  10. Replies
    10
    Views
    871

    Besides corrosion issues, what references can you...

    Besides corrosion issues, what references can you cite that would not allow this to pass? Thanks.
  11. Replies
    10
    Views
    871

    Cat IV Wall Termination

    I'm a home inspector and have come across this and I don't like it.
    American Standard model # AL C1B060A9361AE, Yr. 2012

    Cat IV, 60K, installed as a non-direct vent. I am looking for some real...
  12. Replies
    5
    Views
    560

    Thanks much.

    Thanks much.
  13. Replies
    5
    Views
    560

    I was told on another site that the valve could...

    I was told on another site that the valve could have leaked, sometime in the past, and had been replaced/rebuilt but the valve motor was reused which is not a problem.
  14. Replies
    5
    Views
    560

    Water Stains on Zone Valves

    Several of these zone valves had stains like they had past leaks. They may have self-sealed. I don't know. I found four out of 33 that had active leaks and a bunch with stains beneath.

    If they had...
  15. Vent termination, direct vent vs. mechanical vent

    Why does a direct-vent appliance, 2 pipe (over 50K BTU) have a 12 clearance termination from windows, etc., and a non-direct (one pipe) have a 4 clearance from the same?

    NFPA 12.9.2 A...
  16. Replies
    24
    Views
    2,003

    Both data plates were on the same unit. That's...

    Both data plates were on the same unit. That's odd, isn't it? 4 ton and 5 ton. The one with the whacked out refrigerant line went to the furnace on the 3rd floor.
  17. Replies
    24
    Views
    2,003

    None taken. Thank you for the correction.

    None taken. Thank you for the correction.
  18. Replies
    24
    Views
    2,003

    Could this have been done because the AC was...

    Could this have been done because the AC was grossly oversized to begin with and they are trying to compensate without replacing the system? Hence, the cut line and new configuration?
  19. Replies
    24
    Views
    2,003

    Thanks. The original coolant line had been cut...

    Thanks.
    The original coolant line had been cut and replaced with this set up. I'm a home inspector and I told my client that this was puzzling.
  20. Replies
    24
    Views
    2,003

    AC Coolant Line Loops

    The far AC unit in the photos (6 ton, I believe) makes 5 coolant line u-turns under this deck before it heads up the wall to the 3rd floor. What's the reason?