Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: scepter

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    551

    LonWorks Intergration Help

    I have been tasked with integrating 5 Trane MP 580’s into an existing LNS Lonwork system. I have no access to the existing system yet. No idea what vender. At this point in time they are requesting...
  2. Replies
    5
    Views
    715

    Thanks Reaper! That is what I was doing wrong....

    Thanks Reaper!

    That is what I was doing wrong. I was openning Trabsfer.exe with windows.
    When I go back I will open it in dos.

    Thanks

    Scepter
  3. Replies
    5
    Views
    715

    That is what I am using, a regular cable with a...

    That is what I am using, a regular cable with a null modem adapter on it.
    It works with the DX9100's.
  4. Replies
    5
    Views
    715

    Companion db upload ?

    I have a JCI Companion board that I am trying to upload the database to integrate to the system. I have Transfer.exe and Noterm.exe and I am unable to upload the database. I keep getting the errors...
  5. Thread: LAN comm. help

    by scepter
    Replies
    8
    Views
    1,002

    Problem found. The BCU in question was a BBMD and...

    Problem found. The BCU in question was a BBMD and come to find out there was Fieldsever that was a BBMD too with this BCUs address in its BBMD tables. We left the Fieldserver as the BBMD and have had...
  6. Thread: LAN comm. help

    by scepter
    Replies
    8
    Views
    1,002

    1)Are your rj-45 connections solid? (YES, and...

    1)Are your rj-45 connections solid? (YES, and even a new cable has been run and tested), have you tried a different port on the switch? (YES we have.)I would start there, have you brought IT into...
  7. Thread: LAN comm. help

    by scepter
    Replies
    8
    Views
    1,002

    Not exactly. If we power down the device and...

    Not exactly. If we power down the device and reapply power is comes back on. We haven't just disconnected the LAN and then reconnected, if that is your question.

    scepter
  8. Thread: LAN comm. help

    by scepter
    Replies
    8
    Views
    1,002

    LAN comm. help

    We have a Trane BCU and an iLon 600 in a building connected to the LAN. These two controls will lose and regain communications for no apparent reason. We are unable to ping either of their IP...
  9. Replies
    45
    Views
    6,099

    sysint please elaborate

    You stated earlier that you recommend replacing the dampers along with the actuators in a Carrier VVT system.
    Why is that?

    Thanks scepter
  10. Thread: JCI Direct

    by scepter
    Replies
    5
    Views
    1,089

    Thanks OK, That is pretty much what I did. I...

    Thanks OK,

    That is pretty much what I did. I need to double check my wiring just to be sure.

    scepter
  11. Thread: JCI Direct

    by scepter
    Replies
    5
    Views
    1,089

    OK, Can you tell me your pin configuration and...

    OK,
    Can you tell me your pin configuration and describe how you are connecting?
    What comm port driver are you using?
    Thanks
    scepter
  12. Thread: JCI Direct

    by scepter
    Replies
    5
    Views
    1,089

    JCI Direct

    We recently picked up a couple of building with JCI NCMs and UNTs and VAVs.
    I picked up a copy of M-Tools and have tried to connect to building a couple of ways.
    First I tried to go through the...
  13. Replies
    4
    Views
    763

    RTAA-Phase reversal problem

    We have a RTAA that keeps tripping on “Phase Reversal Protection Loss”.
    We have replaced compressor contactors and compressor Cts. We have no indication of the building loosing a leg of power or...
  14. Replies
    1
    Views
    563

    We have a building with the Parker Carrier...

    We have a building with the Parker Carrier control product. Customer wants to upgrade the control system. What we have as far as equipment is a VAV RTU that is sending the cool air down the ductwork...
  15. Replies
    3
    Views
    998

    I heard a rumor about who actual owns Alerton but...

    I heard a rumor about who actual owns Alerton but I want to hear it from you guys.
  16. Replies
    2
    Views
    463

    The laptop is running XP pro also. I have...

    The laptop is running XP pro also.

    I have checked for windows updates and modem driver updates for the desktop. Everything is up to par.

    When I try to connect, I have double checked and even...
  17. Replies
    2
    Views
    463

    I am having problems with my Dell desktop...

    I am having problems with my Dell desktop computer (running XP Pro) . I am unable to dial into a Honeywell LCB site that my Dell laptop can. With my laptop I am using a V92 Modem Blaster modem and I...
  18. Thread: McQuay chiller

    by scepter
    Replies
    1
    Views
    752

    I have a McQuay chiller- AGZ050 that will not...

    I have a McQuay chiller- AGZ050 that will not bring on the 4th compressor because it is sensing a high “chiller current” draw of 125% with three compressors running. I did check each compressor...
  19. Thread: SLTA help

    by scepter
    Replies
    1
    Views
    503

    I have a new customer with several buildings with...

    I have a new customer with several buildings with the Honeywell LCBS in it. One of these buildings I am unable to dial into the system. It is a very small site, just one Building Manager, a display,...
  20. Thread: comparable pay

    by scepter
    Replies
    22
    Views
    2,243

    I for one enjoy osiyo’s posts when I am not in a...

    I for one enjoy osiyo’s posts when I am not in a rush. Sometimes I am just searching for the answer and with his posts one needs to take the time to “listen”. I find that he has a lot of knowledge...
  21. Thread: comparable pay

    by scepter
    Replies
    22
    Views
    2,243

    Codewriter, I like those pay rates. What part...

    Codewriter,

    I like those pay rates.
    What part of the country are you in?
    You don't see rates like those in the South-East.

    scepter
  22. Thread: Andover Info

    by scepter
    Replies
    8
    Views
    991

    Dave, That is how I am going to approach the...

    Dave,

    That is how I am going to approach the customer next week. Just lay it out on the table and explain that what they bought a very proprietary system and we are currently unable to service it....
  23. Thread: Andover Info

    by scepter
    Replies
    8
    Views
    991

    Freddy, The display is very basic, just a...

    Freddy,

    The display is very basic, just a numerical keypad with “backspace, shift and enter” buttons so when you ask about the F2 & F3 keys I don’t have it.

    Yesterday I went through every point...
  24. Thread: Andover Info

    by scepter
    Replies
    8
    Views
    991

    Can anyone out there sell this service tool, LSX...

    Can anyone out there sell this service tool, LSX 280?

    Is there any other software that I could get that would allow me to access these controls?

    The problems that I am seeing are that some area...
  25. Thread: Andover Info

    by scepter
    Replies
    8
    Views
    991

    Freddy, Without the CX-9XXX control can this...

    Freddy,

    Without the CX-9XXX control can this system dial out alarms?
    The Ix170, is that the Lap-top service tool? I see that listed as a LSX 280.

    I have listed the controls in the electrical...
Results 1 to 25 of 89
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image