Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: MetroAir

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    0
    Views
    237

    Flat Rate Pricing Book

    I have a out dated Exel spreadsheet I use to update prices and print out for our techs so they have a price book. I am not ready to move to notepads yet, so does anyone use a flat rate software...
  2. Replies
    4
    Views
    344

    I work on heat pumps everyday. I live in central...

    I work on heat pumps everyday. I live in central Florida. It can be tricky working on heat pumps in florida especially when temps are below 55. Its not too hard though as long as you know the...
  3. Replies
    20
    Views
    1,028

    I deal a lot with Trane and I didn't see anywhere...

    I deal a lot with Trane and I didn't see anywhere in these posts about making sure the pan was clean. Take the top panel and bottom panel off. Then take the metal shield plate off the front of the...
  4. Replies
    1
    Views
    411

    I normally don't see them there. They normally...

    I normally don't see them there. They normally leak where your lines go under the condenser coil. Over the years the condenser coil will settle down on the lines and vibrate a hole in them.
  5. Replies
    22
    Views
    2,061

    Look at My Profile Pic!!

    Look at My Profile Pic!!
  6. Replies
    14
    Views
    1,941

    I install Trane almost every day. I highly...

    I install Trane almost every day. I highly recommend the XR15 with the Tam7. I had the choice to put any brand in my house last year...I went with Trane.
  7. We are a small operation, family owned and...

    We are a small operation, family owned and operated. We have been around since 1973 and only have 4 trucks on the road. My dad started this company and I just got my mechanical license. We don't...
  8. Replies
    5
    Views
    602

    About 5 years ago when the roof foam became...

    About 5 years ago when the roof foam became popular, we had several builders use this after we were done with the job. Just to get that better "seal" on the home. I really dislike that stuff. ...
  9. Replies
    6
    Views
    540

    De-humidistat Question

    How do I ask this?.... Do they make a de-humidistat that will work to control the humidity regardless of what the temperature is? We install the TCONT803 all the time but they will run only if there...
  10. Replies
    2
    Views
    511

    2.5 tons = 1000 cfm. 14" flex = 700 cfm. You...

    2.5 tons = 1000 cfm. 14" flex = 700 cfm. You need more return. 16" flex will allow 1000 cfm.
  11. Replies
    4
    Views
    721

    M12 tubing cutters?

    Always looking to be more efficient. Anyone use the m12 Milwaukee tubing cutters? Advice?
  12. Replies
    1
    Views
    420

    Replacing hoses

    I replace my gauge hoses about once a year. I do installs everyday and run service so they take alot of abuse between vacuuming systems and then charging them. How often to you all replace hoses? ...
  13. Great idea. I do alot of start-ups and...

    Great idea. I do alot of start-ups and maintenance. I always have a sharpie on me to mark start up dates, amp draws and any repairs that have been done. It saves alot of time and aggravation...
  14. Replies
    2
    Views
    942

    Lead Installer Needed Pinellas County FL

    In much need of a lead residential/commercial installer. We mainly install Trane. Great pay and lots of work. Please email resume to metroair1973@gmail.com

    We are a drug free company
    Clean...
  15. Replies
    14
    Views
    1,709

    Im in central Florida. By code now we have to...

    Im in central Florida. By code now we have to install lockable caps, use armaflex that is 3/4" thick, use R-8 board and flex duct on new construction, programmable t-stats, verify and sign paperwork...
  16. Replies
    11
    Views
    1,212

    I work in Florida and if there is not a breaker...

    I work in Florida and if there is not a breaker in the heater you have to install a disconnect. Some closets are so tight you have to put in a aux heater with a breaker in it. Plus, if you install...
  17. Replies
    7
    Views
    1,278

    I install gam and tam units almost everyday. Not...

    I install gam and tam units almost everyday. Not sure if this will help but for some reason the liquid line on these units will give off a high pitch noise. If have had to go back on two of them...
  18. Replies
    6
    Views
    729

    I am only going by memory here....but I install...

    I am only going by memory here....but I install alot of the tcont803 Trane t stats which is made by Honeywell and you first have to set something up in option 340 to make the rest work right or else...
  19. Replies
    4
    Views
    958

    I have installed about 6 alarm systems by Jackson...

    I have installed about 6 alarm systems by Jackson Systems and they work well. I have Hooked them up with high voltage, and low pressure controls. They work great and easy to install but......after...
  20. Replies
    11
    Views
    1,894

    Trane tam/gam unit....input?

    At first I didn't like them just because it changed up my install procedure. After working with them all last year...I really like them. Still having trouble following all the blinking lights...but...
  21. Replies
    38
    Views
    2,380

    Hate to admit but I don't change mine often...

    Hate to admit but I don't change mine often enough. I use a micron gauge though on every vacuum and still pull below 350 microns. I flush every line set I can't change out and alway leak check...
  22. Replies
    33
    Views
    6,035

    I agree to check static pressure. If it's 80...

    I agree to check static pressure. If it's 80 degrees out with only 50/180 it seems to be undercharged. Once temps drop at night, that would cause it to freeze up. Everyone else gave good input...
  23. Replies
    14
    Views
    1,704

    Do a continuity test right off your contactor...

    Do a continuity test right off your contactor between the red and black/blue wire (Trane unit). If your meter doesn't beep then circuit is open (internal overload). I get out my alligator clips and...
  24. On a Trane communicationg system there is not a...

    On a Trane communicationg system there is not a run cap for the fan cause it's variable speed. The compressor will start first and then the fan starts. Communicating systems are very picky. Put...
  25. I have installed many communicating systems and...

    I have installed many communicating systems and over the past year I have had to replace several high pressure cut out sensors. It seemed to only happen on the 4 ton 20i's. In one situation, it was...
Results 1 to 25 of 79
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine