Search:

Type: Posts; User: BALloyd

Page 1 of 13 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    8
    Views
    182

    Let's put it this way......if you are required to...

    Let's put it this way......if you are required to foot so many expenses why do you need him? Why not start your own business?
  2. Thread: 410

    by BALloyd
    Replies
    21
    Views
    256

    I have a Beta VCR for sale if you want it. ;-)

    I have a Beta VCR for sale if you want it. ;-)
  3. Replies
    2
    Views
    91

    Possibly picking up electrical interference? Did...

    Possibly picking up electrical interference? Did he use shielded wire?
  4. Replies
    36
    Views
    2,334

    Since you have so many systems and your employer...

    Since you have so many systems and your employer bean counters are involved here is what I might propose.

    Next coil you find leaking, say a 3 ton, replace with new coil. Weld old coil shut with...
  5. I would be concerned that important details such...

    I would be concerned that important details such as pricing were not discussed in detail prior to you joining this endevour. It is all in the details.

    You are going to have to convince the owner...
  6. Replies
    21
    Views
    773

    It is all about the feel. Use the Force, not the...

    It is all about the feel. Use the Force, not the torque wrench.
  7. Replies
    21
    Views
    773

    No. The only correct tightening torque is the...

    No. The only correct tightening torque is the exact same torque that is required to remove the bottle cap off of the beer bottle. No more...no less.
  8. How come they did not paint the gas lines "lucky"...

    How come they did not paint the gas lines "lucky" red? Lol
  9. Replies
    12
    Views
    382

    Just apply it and assemble. Where are you getting...

    Just apply it and assemble. Where are you getting your fittings? Maybe try a different brand.
  10. Replies
    12
    Views
    382

    I have never had a problem with either of those...

    I have never had a problem with either of those products leaking on oil line connections.
  11. Replies
    80
    Views
    1,514

    https://www.google.ca/url?sa=t&source=web&rct=j&ei...

    https://www.google.ca/url?sa=t&source=web&rct=j&ei=cZKNVd_dEoHloATH0YP4BA&url=http://sporlanonline.com/literature/10/10-10.pdf&ved=0CBsQFjAA&usg=AFQjCNGec-H2QcF93frmZuTjsJhzgfSsMQ

    This Sporlan...
  12. Replies
    80
    Views
    1,514

    Are the txv powerheads removable? If so pumpdown...

    Are the txv powerheads removable? If so pumpdown system. Remove head off one. Stick a dime underneath and tighten head back down. If txv now feeds, powerhead is toast.

    You really need ports on...
  13. Replies
    80
    Views
    1,514

    Check your screens.

    Check your screens.
  14. Thread: New here

    by BALloyd
    Replies
    21
    Views
    638

    Wrong....it is still harmful, just not as bad as...

    Wrong....it is still harmful, just not as bad as CFC and HCFC refrigerants.


    As for the oil you use at work, it is likely PAG oil which is incomptable with motor windings, so I would suggest you...
  15. Replies
    16
    Views
    624

    Must have bought an underflow switch by mistake.

    Must have bought an underflow switch by mistake.
  16. Thread: a32 vs oxy

    by BALloyd
    Replies
    9
    Views
    517

    Oxy.

    Oxy.
  17. Thread: ac nightmare

    by BALloyd
    Replies
    10
    Views
    450

    Carrier requires bi-flow LLS valves on all long...

    Carrier requires bi-flow LLS valves on all long line heat pump applications to prevent liquid migration. Might want to find out what York recommneds
  18. Replies
    27
    Views
    1,083

    How much oil came out of burned out compressor...

    How much oil came out of burned out compressor vs. manufacture spec?

    Was their a leak or did you recover all gas when replacing the first compressor?
  19. Replies
    12
    Views
    533

    Yeah except the EPA has no jursdiction to choke...

    Yeah except the EPA has no jursdiction to choke their diesels to death with unnecessary gasser emissions controls.
  20. You think Sears in the US is bad, even they make...

    You think Sears in the US is bad, even they make sure to distance themselves from Sears Canada. Their tool section became a laughing stock about 7 years ago.
  21. Replies
    14
    Views
    609

    I found one valve like thay before.....just...

    I found one valve like thay before.....just freewheeling. Replaced it.
  22. Replies
    1
    Views
    178

    Mitsubishi. I have not seen any restrictions...

    Mitsubishi. I have not seen any restrictions against using all floor mounts as long as they meet the sizing requirements. Rep told me only reason you do not see more floor units is they cost twice as...
  23. Replies
    14
    Views
    2,425

    Quote to fix it right. If they do not accept,...

    Quote to fix it right. If they do not accept, walk away.
  24. Replies
    44
    Views
    1,967

    New unit with an oem replacement motor....30...

    New unit with an oem replacement motor....30 minutes maybe. Took me 30 mins to clean 10 years of crud off the squirrel cage of the blower I did the other day, never mind install the motor.
  25. X2. I have had single phase R + S = C many times....

    X2. I have had single phase R + S = C many times. When it did not it was either my measurement tool or a bad compressor with a winding to winding short.

    Put your meter on ohms and touch your test...
  26. Also. Do not chew your nails.

    Also. Do not chew your nails.
  27. Your flux capacitor is out of phase.

    Your flux capacitor is out of phase.
  28. Replies
    30
    Views
    1,431

    Invest in the new H-10 pro. Supposed to have...

    Invest in the new H-10 pro. Supposed to have increased sensitivity to R-410. RSL can get you one.
  29. Replies
    1,151
    Views
    124,588

    X2. I have used cable ties, twist ties, and...

    X2. I have used cable ties, twist ties, and other straps to hang my temp probes in the supply and return of RTU's
  30. Replies
    36
    Views
    884

    Yes. We have a pager for on call as well.

    Yes. We have a pager for on call as well.
  31. X2. MC is my go to bag now.

    X2. MC is my go to bag now.
  32. Replies
    15
    Views
    2,121

    Ditto. I think I would run if we could not rip it...

    Ditto. I think I would run if we could not rip it all out and start over. That is a freaking disaster.
  33. Tell the strata coucil to get a different company...

    Tell the strata coucil to get a different company out to look at it, perferably once with less suck.
  34. That only applies to apprentices starting after...

    That only applies to apprentices starting after May 1, 2015. Did they not sign you up as an apprentice under JTAC while taking the foundation program? If you have an ITA number prior to May 1st you...
  35. Replies
    19
    Views
    1,038

    WIF evap with an internally equalized TXV??? How...

    WIF evap with an internally equalized TXV??? How small is this evaporator?
  36. Thread: infinity

    by BALloyd
    Replies
    22
    Views
    1,478

    How far is the UI from the unit?

    How far is the UI from the unit?
  37. Replies
    10
    Views
    893

    Both...his new tech needs a new home. Lol

    Both...his new tech needs a new home. Lol
  38. Replies
    48
    Views
    2,354

    Are there ceilings fans running close to the case?

    Are there ceilings fans running close to the case?
  39. Replies
    12
    Views
    835

    The key is to let it warm up. I do what JP does....

    The key is to let it warm up. I do what JP does. When I turn mine on I walk away and do something else for a few minutes.
  40. Replies
    16
    Views
    1,140

    Call manufacturer for install requirements.

    Call manufacturer for install requirements.
  41. Replies
    12
    Views
    1,170

    Well at least the customer cannot argue with the...

    Well at least the customer cannot argue with the diagnosis.
  42. Replies
    9
    Views
    518

    Make sure the drain is piped properly and...

    Make sure the drain is piped properly and actually drains.
  43. Replies
    23
    Views
    1,353

    Not our installation. Not that new...at least ten...

    Not our installation. Not that new...at least ten years old, but still should not have been leaking.
  44. Replies
    23
    Views
    1,353

    We had some supermarket linesets popping pinhole...

    We had some supermarket linesets popping pinhole leaks through the copper. We were replacing 60-100 foot sections. Garbage chinese copper.
  45. Replies
    31
    Views
    1,166

    Hot gas? Define stays in longer? You have seen...

    Hot gas?

    Define stays in longer? You have seen it stuck in defrost?

    What is your drip time set to?
  46. Replies
    73
    Views
    4,027

    Get a magnet on the reversing valve and find out...

    Get a magnet on the reversing valve and find out where the slide is currently positioned.
  47. Replies
    23
    Views
    1,353

    Brutal.

    Brutal.
  48. Replies
    16
    Views
    1,399

    A crack is almost a guarantee. Seen this way too...

    A crack is almost a guarantee. Seen this way too many times.
  49. Thread: Runs good

    by BALloyd
    Replies
    79
    Views
    6,034

    Your looking at the wrong indoor unit? Lol

    Your looking at the wrong indoor unit? Lol
  50. We use Robertsons. Not sure why those guys are...

    We use Robertsons. Not sure why those guys are using Philips.
Results 1 to 50 of 602
Page 1 of 13 1 2 3 4

Related Forums