Search:

Type: Posts; User: Iceman_pdx

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    4
    Views
    191

    Cleaning ductless fan

    Gentleman,

    I read or hear something about a funnel or something used to clean the indoor blower wheel. Any help?
  2. Replies
    0
    Views
    387

    Service tech needed in Portland, Or

    Hello,

    Looking for a service tech, experienced for residential and light commercial HVAC repair work. Refrigeration know.edge would be a plus but not required. Let me know if interested
  3. Replies
    20
    Views
    660

    Do they make a 6.5 split heat pump

    Gentleman,

    My cousin asked me to check on a price for a 6.5 ton heat pump for his friend. Do they make a 6.5 ton outdoor single phase heat pump? Thanks
  4. Replies
    37
    Views
    2,244

    I don't where we are at now. Furnace to Firefly...

    I don't where we are at now. Furnace to Firefly to some English teacher that's complaining about people's grammar and english. Not that anyone cares, but furnace has been working fine. Wish I knew...
  5. Replies
    37
    Views
    2,244

    Lol @ snapperhead

    Lol @ snapperhead
  6. Replies
    37
    Views
    2,244

    Lol! Lmao ya hell no @ John

    Lol! Lmao ya hell no @ John
  7. Replies
    37
    Views
    2,244

    Went to job today. Everything was working as it...

    Went to job today. Everything was working as it is every time I'm there. Stat wire was strapped to gas line so I removed it. Opened up J box ground is hooked up but I noticed the neutral and ground...
  8. Replies
    37
    Views
    2,244

    Lmao @ akal and I don't know I'll have to look at...

    Lmao @ akal and I don't know I'll have to look at stat wire today. Thanks
  9. Replies
    37
    Views
    2,244

    Lol @ Firefly

    Lol @ Firefly
  10. Replies
    37
    Views
    2,244

    Furnace is completly off, then they just touched...

    Furnace is completly off, then they just touched gas line and it fired off. Previously unit was off on pressure switch fault, not closing or closed on start up. This was a month ago, and I wanna say...
  11. Replies
    37
    Views
    2,244

    WTF does a TV show have to do with my problem?

    WTF does a TV show have to do with my problem?
  12. Replies
    37
    Views
    2,244

    Touch gas pipe and furnace starts?

    Gentleman,

    Help please. Working on a Lennox/AirFlow gas furnace. Had a error code on pressure switch a month ago. Went thru the entire furnace, checked and cleaned everything.Oh 95% furnace....
  13. Replies
    2
    Views
    578

    That's what I wanna hear. Thanks. Couldn't find...

    That's what I wanna hear. Thanks. Couldn't find any literature but found the Lennox videos that explains how it operates. I should start using this video for customers ahead of time
  14. Replies
    2
    Views
    578

    Lennox XP25 heat pump operation guide

    Hello guys,

    Is there a actual Lennox guide or instruction book that actually tells me and for the homeowner can see, on how this variable speed system is supposed to operate? Ya I read all about...
  15. Replies
    16
    Views
    1,870

    From what I've gathered Nordyne developed this...

    From what I've gathered Nordyne developed this coil to replace there coils that were failing but then found out they couldn't match them with a conventional coil. Then they wanted a pound less of...
  16. Replies
    0
    Views
    427

    Vulcan convection oven # SGH101B

    Gentleman,

    Working on a Vulcan snorkel convection. No schematic, but if u know where I can see one please send. Burners or fan won't come on. Thermostat is good, door switch is good. Is there...
  17. Replies
    16
    Views
    1,870

    Kamersoutdoor, My system is a 13 seer single...

    Kamersoutdoor,

    My system is a 13 seer single stage with a txv indoors. Piston or txv make any difference with this system? What a ass kicking. From what I read this MC coil was Nordynes solution...
  18. Replies
    16
    Views
    1,870

    So what I've gathered is this Nordyne micro...

    So what I've gathered is this Nordyne micro channel evap coil is having issues when it's matched up with a condenser that is a tube and fin coil.
  19. Replies
    16
    Views
    1,870

    Nordyne Micro channel evaporator coils

    Hey guys,

    Anyone familiar with Nordyne micro channel coils? I just ran across one on a job we did. We installed a Lennox 13 seer heat pump with there coil and nothing but issues. In heating mode...
  20. Replies
    22
    Views
    1,804

    Yes indoor pool. Why Desert Aire? I'm wanting to...

    Yes indoor pool. Why Desert Aire? I'm wanting to know why, and is Desert Aire a better system? Will a HRV and a ductless work?
  21. Replies
    22
    Views
    1,804

    Dehumidifier for pool room help

    Hello all :)

    Working on a quote for a new system for a customers pool room. Be our first pool design, appreciate any help. Supplier quoted us a Desert Aire LC-02 dehumidifier, package system...
  22. Replies
    24
    Views
    1,683

    Right on

    Right on
  23. Replies
    24
    Views
    1,683

    Sorry guys, I didn't the latest posts till just...

    Sorry guys, I didn't the latest posts till just now. Didn't go to page 2 of thread. Should of saw these yesterday. IRBH and Brewmaster yes correct lines were criss crossed at pump, that 1/2" line...
  24. Replies
    24
    Views
    1,683

    Update: So went out to look at beer system,...

    Update: So went out to look at beer system, finally had a few minutes to do so, and instead of looking for a problem, I looked for stupid. FOUND IT! Unit was real old but finally found out it was a...
  25. Replies
    24
    Views
    1,683

    **** happens and ya ur right the obvious and...

    **** happens and ya ur right the obvious and stupid escapes is fer sure. I was hoping it was that lol
  26. Replies
    24
    Views
    1,683

    Brewmaster, no it's not reversed. I was hoping....

    Brewmaster, no it's not reversed. I was hoping. That would explain it, look for stupid lol. I just looked at pump photo there's the directional arrows so it's correct
  27. Replies
    24
    Views
    1,683

    Ya I got the tower now. Taps. Thanks duh. U know...

    Ya I got the tower now. Taps. Thanks duh. U know it sounds stupid but stupid would explain this and my lines. I'll have to double check. No of course not lol
  28. Replies
    24
    Views
    1,683

    The line going into container goes all the way to...

    The line going into container goes all the way to bottom and the supply line from container to the taps is only like a 1/2 " into the plastic container. Looking at it u would think it would be deeper...
  29. Replies
    24
    Views
    1,683

    Glycol chiller circulator is the brand m# 556-vht...

    Glycol chiller circulator is the brand m# 556-vht hard to see the numbers on my phone in the pic of tag. 101 here what are we referring to the tower as? I watch the water come out of the lid on the...
  30. Replies
    24
    Views
    1,683

    Do I just need to seal the lines going into...

    Do I just need to seal the lines going into storage tank and fill the extra fill hole?
  31. Replies
    24
    Views
    1,683

    Beer tap refrigeration system help

    Hey guys. Working on a small glycol be tap refrigeration system. I replaced the pump and motor a month ago. Since then, at least I believe I've been losing water/glycol. It's got a small plastic...
  32. Replies
    15
    Views
    955

    N-E-W Jerz This Honeywell E3 point panel has a...

    N-E-W Jerz

    This Honeywell E3 point panel has a internal sensor and a remote sensor. Possible to wire another remote sensor in parallel?
  33. Replies
    15
    Views
    955

    Ya I'm gonna call Honeywell today. Unit isn't...

    Ya I'm gonna call Honeywell today. Unit isn't that expensive ither it looks like. Glad this didn't bite me in the but on this job. Thanks
  34. Replies
    15
    Views
    955

    Thanks N-E-W Jerz that is what I was looking for

    Thanks N-E-W Jerz that is what I was looking for
  35. Replies
    15
    Views
    955

    So I just mount a CO sensor on the wall and let...

    So I just mount a CO sensor on the wall and let sparky take over? Can you send me info on manufacturer of sensor? Is it a control box? I don't know anything about CO sensors or NO2 sensors for these...
  36. Replies
    15
    Views
    955

    Thank You. Sorry. I need to install a CO sensor...

    Thank You. Sorry. I need to install a CO sensor in garage area that turns on the exhaust fan.
  37. Replies
    15
    Views
    955

    CO sensor help for garage exhaust

    Hey guys.

    Need some help. Finishing up installing 3 RTU and a EF in a fire station and I have to install a CO2 sensor and tie it into the EF in garage. Electrician doing the wiring and I've gotta...
  38. Replies
    7
    Views
    653

    Time builder, Ya the way u said it is the...

    Time builder,

    Ya the way u said it is the other way, tap into the transformer before it goes to the board, and the other way is just wire fan circuit thru contacts but that doesn't work cus fan...
  39. Replies
    7
    Views
    653

    I meant "cut" not fit William, ya I understand...

    I meant "cut" not fit

    William, ya I understand the NC & NO contacts on the smoke detector, which will open up if there is trouble. What low voltage wiring am I taking thru this? Am I taking my...
  40. Replies
    7
    Views
    653

    Smoke detector wiring help

    Gentleman,

    I have a external smoke detector I installed. It's on a Carrier 48HC gas pack. I'm supposed to fit the JMP3 wire and wire thru the two terminals. What wire am I sending thru this?
  41. Carrier 48HC GAS PACK smoke detector and power exhaust help

    Gentleman,

    Attached pic of board on Carrier RTU, need to wire smoke detector in. Do I cut JMP3 and wire my 24v fan circuit through there?

    Where do I wire the power exhaust to? Is there a PEC...
  42. Replies
    2
    Views
    631

    Seeking HVAC/R tech Portland, Or

    Looking for HVAC/R service tech for repair work in Yamhill and Washington County. Send resume
  43. Replies
    5
    Views
    439

    I didn't say I changed a board out before with...

    I didn't say I changed a board out before with this same issue. I said this is the 2nd unit I have seen in the last few weeks with the manual harvest button not working. Both units instead of hoping...
  44. Replies
    5
    Views
    439

    Yes I ran it threw 4 or 5 drops after I got evap...

    Yes I ran it threw 4 or 5 drops after I got evap defrosted, which I had to do with hot water cus manual defrost won't work. Replaced thickness control and system working again, BUT the manual harvest...
  45. Replies
    5
    Views
    439

    Scotsman control board help

    Gentleman,

    Hello again. Working on a Scottsman C1448 machine today not working duh. Had to defrost evaporators and hit the blue manual harvest button on control board. Instead of going into...
  46. Replies
    4
    Views
    1,887

    Have no idea? Are all DDC systems different? The...

    Have no idea? Are all DDC systems different? The one I dabble with now is a Metasys system.
  47. Replies
    4
    Views
    1,887

    DDC Training

    Hello guys,

    Been doing all this HVAC/R crap since I was old enough to carry my Dad's tools, but now I need to jump on the DDC bus before it passes me by. I have one DDC system I work on, but...
  48. Replies
    15
    Views
    1,237

    So compressors are up and running. Amped out ok...

    So compressors are up and running. Amped out ok and system pressures are ok. I told customer that compressors reset and operating but don't know what damage may have been caused and will note that on...
  49. Replies
    15
    Views
    1,237

    Most definitely new driers with a oil sample....

    Most definitely new driers with a oil sample. Gonna head over and check the system in a hour or so. Let everyone know happens
  50. Replies
    15
    Views
    1,237

    I'm anxious to see if these compressors will...

    I'm anxious to see if these compressors will restart today. Ither way there went warranty and my invoice will say need to replace

    Thanks guys
Results 1 to 50 of 174