Search:

Type: Posts; User: pctech

Page 1 of 11 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Stereo Systems

    by pctech
    Replies
    16
    Views
    348

    i still have my system dennon direct drive turn...

    i still have my system
    dennon direct drive turn table:)
    Harmon cardon receiver.
    same with the cassette deck.
    and cd player.
    Sony pro grade 8 track from a radio station unused until i got it...
  2. Replies
    9
    Views
    300

    I second that statement . its all in the install...

    I second that statement .
    its all in the install and the installer.
    you can have the best and it works like crap .
    or the worst and it runs like a top.
    all boils down to the install job:)
  3. for an emg set up until you get the right set up...

    for an emg set up until you get the right set up or parts maby.
    Permanently NO WAY.
    do it right
  4. Replies
    16
    Views
    944

    the order thats only as good as the paper its...

    the order thats only as good as the paper its printed on and most police depts arnt in a hurry to enforce them.
  5. Replies
    3
    Views
    693

    looks good but the second unit does not seem to...

    looks good but the second unit does not seem to fit flush and tight to the ceiling like the first unit does other wise grate work
  6. Thread: Latest swap out

    by pctech
    Replies
    8
    Views
    1,267

    nice job but i would have used sealtight looks...

    nice job but i would have used sealtight looks better and should not be so close to the gas line .
    whare iam from they have to be separated by a set distance
  7. Replies
    13
    Views
    2,513

    more like one of the many low paid subcontractors...

    more like one of the many low paid subcontractors both services have been known to use:)
  8. Replies
    8
    Views
    2,272

    still would be required to have a gas company...

    still would be required to have a gas company provided shut off in maine
  9. Replies
    50
    Views
    5,757

    those who brag about how many cars SUVS and...

    those who brag about how many cars SUVS and houses they own never get a call from me .
    i dislike those who brag about how well they live off the costumers dime
    do i diss you for earning what you...
  10. Replies
    9
    Views
    530

    i would leave it on automatic my self. running...

    i would leave it on automatic my self.
    running it on low will add about 40 bucks to you're power bill or more.
    and then it just moves the moist cool air around the house and off the coil until it...
  11. Replies
    4
    Views
    941

    looks like a job that was done for a corner store...

    looks like a job that was done for a corner store so the condenser is out of sight:)
  12. Replies
    8
    Views
    2,272

    that shut off isnt even legal in maine whare iam...

    that shut off isnt even legal in maine whare iam from.
    would be locked by the gas company with a cut proof lock:)
  13. Replies
    6
    Views
    1,184

    where iam from you would have to mount the...

    where iam from you would have to mount the disconnect switch higher up or make it an explosion proof box and cover due to how close it is to the gas line and water heater.
    other then that good work
  14. needs a cover over the on off switch to meet...

    needs a cover over the on off switch to meet code.
    other wize looks good
  15. Replies
    12
    Views
    1,111

    I see day light whare the line set goes though...

    I see day light whare the line set goes though the wall seal it up other wize looks good
  16. Replies
    7
    Views
    1,542

    youre kennmore is actualy made by electroux :) i...

    youre kennmore is actualy made by electroux :) i own the actual ac under its normal name works grate
  17. Replies
    24
    Views
    2,078

    the large tank is for domestic hot water off the...

    the large tank is for domestic hot water off the boiler.
    a lot of large apartment complexes do it this way where iam from.
  18. where iam from you HAVE to have a disconnect at...

    where iam from you HAVE to have a disconnect at the unit if the braker panel is NOT with in 30 feet direct line of sight.
    i install them as an added protection device .
  19. Replies
    21
    Views
    3,744

    most complex maintenance men i know are jerks....

    most complex maintenance men i know are jerks.
    one from my town thinks he is always right tenant is always wrong.
    but i know some that do top notch work
  20. Actually the fuse disconnect switch is still sold...

    Actually the fuse disconnect switch is still sold in my area and is used on the really low budget installs.
  21. Replies
    15
    Views
    2,724

    the power feeds look dodgy to me why not just put...

    the power feeds look dodgy to me why not just put one new one in and do it right
  22. at least he wrapped it all in electrical tape...

    at least he wrapped it all in electrical tape most don't take the time to do even that:)
  23. Thread: Jumper

    by pctech
    Replies
    20
    Views
    2,148

    i hate those crimp on wire nuts not as good a...

    i hate those crimp on wire nuts not as good a solid connection as the old time tested screw on kind:)
  24. Replies
    31
    Views
    1,800

    6.0 cents all day 24 7 for me:)

    6.0 cents all day 24 7 for me:)
  25. Replies
    13
    Views
    1,521

    top notch install i would have run the low...

    top notch install i would have run the low voltage wiring in seal tite just for the neatness look
  26. Replies
    28
    Views
    4,219

    the tub no has to be matching pipes not one of...

    the tub no has to be matching pipes not one of each type.
    and the faucet has to be secured to something that tub its being held up by the connections to the pipes.
  27. Thread: creative

    by pctech
    Replies
    5
    Views
    1,528

    Did it actually work

    Did it actually work
  28. Thread: Shorts

    by pctech
    Replies
    14
    Views
    768

    i love it

    i love it
  29. Replies
    58
    Views
    4,764

    why not do it to impress you're self and you're...

    why not do it to impress you're self and you're company's rep not just the guys on this site?
  30. Replies
    26
    Views
    2,850

    only thing i would have done is used cement...

    only thing i would have done is used cement cinder blocks for the base so if the basement ever floods the base of the unit wont rot and the furnace then get ruined from the base rotting out
  31. Replies
    16
    Views
    1,909

    one thing i wanted to ask why not run the low...

    one thing i wanted to ask why not run the low voltage wiring in sealtite?
    i do to protect it from the home owner:)
  32. Replies
    16
    Views
    1,909

    VERY nice job you're job looks so much better...

    VERY nice job you're job looks so much better then the plummer who did the water heater an old state that unit should be redone no disconnect by the unit no drain pan under the unit.
    no shut off on...
  33. Replies
    13
    Views
    1,701

    one thing i don't see is a disconnect on or close...

    one thing i don't see is a disconnect on or close to the unit .
    do you have one in Maine i have to put one with in 20 feet of the unit or on the unit it self.
  34. Replies
    13
    Views
    1,701

    well done line set nice and tight to unit with...

    well done line set nice and tight to unit with proper bends.
    and i love seeing the wiring in the sealtite job like i would do
  35. depends on the state :)

    depends on the state :)
  36. i would ask to have them fixed or offer to have...

    i would ask to have them fixed or offer to have them fixed .
    i have seen installers techs ect with missing teeth and they do top notch work and installs ect.
    its the skills you hire not the looks.
  37. Replies
    28
    Views
    4,219

    so does the plumbing to the tub and its heater...

    so does the plumbing to the tub and its heater upstairs.
    someone who was to cheap to pay us pros to do it right
  38. Replies
    12
    Views
    1,941

    you cant fix stupid:)

    you cant fix stupid:)
  39. Replies
    24
    Views
    3,389

    I wont do it period no way no how. not even to...

    I wont do it period no way no how.
    not even to my own furnace.
  40. not to mention its illegal to discriminate...

    not to mention its illegal to discriminate against someone who cannot afford the dental work
  41. Replies
    13
    Views
    1,573

    i would offer the client to go back and do it to...

    i would offer the client to go back and do it to code the code the other poster spoke of is in Maine where iam from as well.
  42. Replies
    15
    Views
    2,265

    one or 2 models are where iam from you can...

    one or 2 models are where iam from you can actually put a normal furnace as long as it fits in the closet and vents and draws air according to the towns code.
  43. Replies
    15
    Views
    2,265

    those 2 things should have been done when you did...

    those 2 things should have been done when you did the job the first time:) other wize good work
  44. Replies
    24
    Views
    3,389

    In the state of Maine it is 100% illegal to do so...

    In the state of Maine it is 100% illegal to do so i got one company in trouble with the state for doing exactly that at my place of work
  45. Replies
    13
    Views
    1,505

    could you have run the condensate drain lines so...

    could you have run the condensate drain lines so you didn't need a pump? i try to do so i see a pump as one more item to fail and cause floods
  46. Replies
    13
    Views
    1,505

    seal tite on disconnect from inside should have...

    seal tite on disconnect from inside should have been formed in to a U to keep water out of it as seatite can leak after time of hot and cold i always run mine with a U bend to keep water out:)
  47. Replies
    15
    Views
    2,557

    where iam from its conduit or write up by the...

    where iam from its conduit or write up by the inspector
  48. Replies
    15
    Views
    2,557

    it should be connected to the pipe directly to...

    it should be connected to the pipe directly to its left.
    unless you don't show another connection to it in the picture
  49. I would have called the original office manager...

    I would have called the original office manager my self on the first call.
    those project managers are trained to cut costs to the bone.
    one of the places i have gone through is pure profit of 555...
  50. In my area that romex would have to be in conduit...

    In my area that romex would have to be in conduit hole or no hole and this idiot didn't take the time to do it right
Results 1 to 50 of 525
Page 1 of 11 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards