  1. Replies
    12
    Views
    310

    Thanks - ill pull some juice and see what happens...

    Thanks - ill pull some juice and see what happens - then formulate a plan. Thank y'all for the help.
  2. Replies
    12
    Views
    310

    High head- normal suction

    Hey guys- heading back out tomorrow on a no cool call back. First call found pressures (410A) 110/655. ID temp around 78 and OD temp 97. Cleaned condenser and got head to drop down around 475 with...
  3. Replies
    7
    Views
    269

    I saw that chart in IMC code book. But, I still...

    I saw that chart in IMC code book. But, I still know there is a chart that shows what size your single drain line needs to be when you terminate into it from (2) or more lines. Example- (2) 3/4...
  4. Replies
    7
    Views
    269

    condensate line sizing chart

    I used to have a chart that showed proper condensate termination line sizes for instances where 2 or more condensate drain lines are connected. I see minimums for a condensate drain size per ton in...
  5. Replies
    22
    Views
    693

    Is comfort R activated in heating?

    Is comfort R activated in heating?
  6. Replies
    22
    Views
    693

    If the sensing bulb lost chg then it would shut...

    If the sensing bulb lost chg then it would shut off TXV correct?
  7. Replies
    22
    Views
    693

    Thanks- just so I'm clear..is it because the...

    Thanks- just so I'm clear..is it because the suction reading is too low that's causing you to think outdoor restriction?
  8. Replies
    22
    Views
    693

    okay- good info. So, now I am just a little more...

    okay- good info. So, now I am just a little more confused...my mentors/tech buddies say different things...leading me to believe I am not the only one confused about HP!

    Consider this- in heat...
  9. Replies
    22
    Views
    693

    Yup- sorry meant to include that....its...

    Yup- sorry meant to include that....its 22...could be a restriction just not sure the best way to tell....if I remove the bulb and pressures stay the same, then is that saying TXV is bad?
  10. Replies
    22
    Views
    693

    Diagnosing in Heat Mode

    Okay- I'm sure similar threads exist, but need to head back out there today and hoping for some input from those more experienced in heat pumps.

    Got a call for no heat/ very little heat. Customer...
  11. Replies
    22
    Views
    1,044

    On # 2. you stated that you do the checks in 2nd...

    On # 2. you stated that you do the checks in 2nd stage and then unplug the Y2 at the bypass solenoid....so this in effect leaves you checking in first stage....correct?
  12. Replies
    22
    Views
    1,044

    alright-ok, that makes sense....just not a lot of...

    alright-ok, that makes sense....just not a lot of experience on the higher end stuff and want to be sure ducks are in a row. Okay, now if I need to service 2 stage scroll do they recommend charging...
  13. Replies
    22
    Views
    1,044

    Thanks all for the help- good folks on this site

    Thanks all for the help- good folks on this site
  14. Replies
    22
    Views
    1,044

    just so I am clear, on a single 2 stage scroll,...

    just so I am clear, on a single 2 stage scroll, if I adjust the T Stat up several degrees then it should kick in Y2 or (second stage). Then, at condenser I should be able to see control voltage...
  15. Replies
    22
    Views
    1,044

    Thanks for the detail Andrew MK....good stuff

    Thanks for the detail Andrew MK....good stuff
  16. Replies
    22
    Views
    1,044

    Checking 2stage compressor

    I know this may sound trivial, but I'm curious how the expert techs activate second stage cool in order to check second stage (T-Stat or jumper at condenser)...I have recently picked up a couple of...
  17. Replies
    9
    Views
    462

    Thanks all for the replies

    Thanks all for the replies
  18. Replies
    9
    Views
    462

    Compressor shot-customer didn't have a lot of...

    Compressor shot-customer didn't have a lot of money to spend- evaporator still functioning fine. Plans to replace evaporator later...got him cool again on his budget. I realize it's not optimal
  19. Replies
    9
    Views
    462

    Replace orifice?

    Question- I'm curious how many techs replace the orifice or put new TXV on an existing evaporator when only changing out the condenser (different brand) I'm thinking you are supposed to put the...
  20. I appreciate the information and it sure clears...

    I appreciate the information and it sure clears some things
  21. Meaning to check to SH or SC

    Meaning to check to SH or SC
  22. Okay- so in heating mode, do you connect gauges /...

    Okay- so in heating mode, do you connect gauges / thermometer on the same places as in cooling mode? It would stand to reason that it would be different locations for line temp measurements since...
  23. Thanks to everyone for the info and excellent...

    Thanks to everyone for the info and excellent insight. sorry have not been keeping closer tabs on my thread,but I've been out of pocket deer hunting.
  24. Trane Heat Pump troubleshooting questions

    Hey- hope everyone is well. I just wanted to toss this out there for some of you who are better at heat pumps than me
    I got called out to a no heat call yesterday (specifically no first stage...
  25. Replies
    7
    Views
    470

    dirty evaporator scenario

    Question- I was curious if anyone knew whether adding refrigerant to a system with a dirty evap coil will actually cool the air better?

    Scenario- tech comes on the scene and slaps gauges and sees...