  1. Replies
    7
    Views
    881

    oil return

    The unit will bring back the oil in about a weeks run time. Best load at over 60%. Make sure your oil return drier and low side line are isulated as this helpes keep the oil suspended in the...
  2. Replies
    18
    Views
    1,502

    apposed force

    The face of the damper blade has equal forse above and below the pivot point. If you can open it easy by hand then you answered the first question. 3.7 in static is high but not unherd of. It may be...
  3. Thread: Hawaiian hvac?

    by synergy
    Replies
    20
    Views
    1,596

    second choise

    If you dont take the job, please forward the details to my e mail.
  4. Replies
    18
    Views
    3,059

    its all the same

    Just bigger nuts. Dont be intimadated. Company's like young go getters as they can beat you up a little. Us old guys are to grummpy and set in our ways.
  5. Replies
    4
    Views
    564

    Yes, the inrush currant of a coil is much like a...

    Yes, the inrush currant of a coil is much like a motor, 5 to 6 times that of operating currant. A transformer can be sized to small if many loads come on at the same time. If the loads are staggard a...
  6. Replies
    4
    Views
    308

    Refrigerant level

    As the coil temperature drops the specific volume of the gas increases, this causes less pounds per minute to be circulated by the fixed volume of the compressor. The mass flow- refrigeration effect...
  7. Replies
    7
    Views
    1,456

    I would like to know what a gravity condenser...

    I would like to know what a gravity condenser coil is, though.
  8. Find the main harness that goes to the economiser...

    Find the main harness that goes to the economiser option and disconnect. ?Trace out the y1 wire and jump it back to the main compressor control circuit.
  9. Replies
    58
    Views
    4,091

    Your reasons all are sound, but I have replaced...

    Your reasons all are sound, but I have replaced maybe 5 heat exchangers in 25 years and if it is common occurance on your units it may be a design issue. Most failures I have seen are on the U bends...
  10. Replies
    1
    Views
    429

    I know a lot of guys like those analog type...

    I know a lot of guys like those analog type vacume gages, but I never could trust them. The pressure changes with any type of movement of the thermistor. I have gone to a micron gauge and put it...
  11. Replies
    2
    Views
    817

    simulate an RTD sensor

    Probably a dumb question but can I use a potentiometer to simulate a temperature to a controller. Is there a tool for just this type of thing.
  12. Replies
    11
    Views
    2,370

    Time will tell

    There in lies the rub i have not seen the this system run in all possible conditions. Thanks for your interest though as this unit has been the most challanging thermodynamic system I have worked on...
  13. The basics

    Oil anaylsis, cut the oil filter apart, vibration anaylsis, check thrust if applicable.
  14. Thread: LLSV

    by synergy
    Replies
    17
    Views
    1,449

    Buy Sporlan

    Piped in new sporlan LLSV, no problems, works as it should. The alco valve removed is shiney, clean, no appartent damage of any kind. I will go out of my way to buy Sporlan in the future.:cheers:
  15. Thread: Duct Problems

    by synergy
    Replies
    18
    Views
    1,195

    Static

    Static pressure should be at its higest at the fan exist and at its lowest at the end of the run, this is due to friction loss through the duct. The duct internal area and the number of exits need...
  16. Replies
    5
    Views
    357

    Is it dripping and tripping?

    Is the oil on the floore from the drip, or is the real problem the oil trip. Does it drip befour it trips. Is there oil in the compressor. Define the "high pressure valve" and why is it restricted.
  17. Replies
    11
    Views
    787

    More info

    Closed loop system, or are you talking city water supply, ground water, ect. How could you use more water? Air will take up the effective surface area of the condenser and raise the head pressure....
  18. Replies
    14
    Views
    785

    Low air flow

    A 27 degree delta T across the evaporator is a problem. Air flow sounds low, check the fan amperage and compare to the other units that are running ok pressures. Depending on the coil arrangement,...
  19. Thread: LLSV

    by synergy
    Replies
    17
    Views
    1,449

    Stem down

    The valve will operate normally with a lower pressure differencial. At 225 psig head and a 60 psig suction it will close off, pump down like normal to 30 psig, compressor shuts off on low pressure...
  20. Thread: LLSV

    by synergy
    Replies
    17
    Views
    1,449

    Thanks

    Will replace, dissect, and report.
  21. Thread: LLSV

    by synergy
    Replies
    17
    Views
    1,449

    Sporlan sounds good

    I may have to go the Sporlan route, pain in the butt to replace at this point, but don't know what else to do. The alco valve has a little round diaphram and a spring. Not to sure on how it works....
  22. Thread: LLSV

    by synergy
    Replies
    17
    Views
    1,449

    In the right direction

    The arrow on the valve is pointed to the TXV, it is in the right way. Don't know what caused the original failure, but this problem is on my short list. It is like 200 PSI Diff is the maximum it can...
  23. Thread: LLSV

    by synergy
    Replies
    17
    Views
    1,449

    In the right direction

    The arrow on the valve is pointed to the TXV, it is in the right way. Don't know what caused the original failure, but this problem is on my short list. It is like 200 PSI Diff is the maximum it can...
  24. Thread: Duct Problems

    by synergy
    Replies
    18
    Views
    1,195

    No static man

    Sounds like you have no static pressure. Too many openings or too many air exits to allow for static pressure to build up and push the air out of the closest registors. Close down some of the dampers...
  25. Thread: LLSV

    by synergy
    Replies
    17
    Views
    1,449

    more info

    Water to water heat pump chiller, one of a kind I think, runs head pressure of 275Psig for hot water to the A/H of 105 degrees. Compressor had failed,after replacing I found the LLSV would at times...