  3. Thread: Lennox G40

    by ksagert
    Replies
    4
    Views
    1,528

    Lennox G40

    So I've been on call through a recent cold snap and a majority of my calls have been as follows:
    Homeowner: "My furnace lights for only 2-5 seconds and then goes out. It only tries 4 times and...
  4. Too many to count!

    The first one that came to mind was one that happened about a month ago. I had been sent about 1.5 hours out of town to install a bunch of equipment into a potato storage. The sparky had pulled...
  5. Replies
    5
    Views
    827

    Anyone worked for/with Gateway? I noticed they...

    Anyone worked for/with Gateway? I noticed they have an office in Vernon (which is more the area I'm looking at). Also anyone heard good or bad about CR Martin Heating or Britech?
  6. Replies
    5
    Views
    827

    Relocating to the Okanagan, BC

    I'm a second year refrigeration mechanic working commercial/residential service looking to relocate to the okanagan, BC. Anyone know of any good companies currently looking to hire? Or any to stay...
  7. Replies
    4
    Views
    1,271

    I also had this problem with a condenser fan...

    I also had this problem with a condenser fan rotating the wrong way. I changed the wire going to T2 with the one going to the capacitor and the direction changed. What is confusing me is that I...
  8. Replies
    4
    Views
    1,271

    Lennox XC13 Condenser

    I spent some time this past week changing a compressor that had been deemed "failed" by one of our other service techs about a week ago. He had also ordered a condenser fan motor and stated on the...
  9. Replies
    40
    Views
    4,968

    If only they all looked like that!!!

    If only they all looked like that!!!
  10. Thread: R-12 AC Unit

    by ksagert
    Replies
    21
    Views
    1,756

    Can "Super-Seal" be used with R-12 or R-409a to...

    Can "Super-Seal" be used with R-12 or R-409a to "fix" the leak? Any opinions on that stuff?
  11. Replies
    32
    Views
    2,653

    TIPS

    Make sure that you tighten the collar the right way the FIRST time. It turns out that the blower shaft in question originally actually did spin inside the bearing, causing the bearing to fail, and...
  12. Replies
    15
    Views
    5,123

    The end...

    Well, I only have a couple of days left of work before I go to trade school, so I won't actually know the outcome of this issue. If I do find out I'll post what happened for sure. Thanks for all...
  13. Replies
    15
    Views
    5,123

    Might be an issue. Some of our install guys...

    Might be an issue. Some of our install guys think it's a waste of nitrogen and it's not really necessary for air conditioning. I'll replace the line drier.
    I did confirm that the TX valve is rated...
  14. Replies
    15
    Views
    5,123

    I received that info from one of our sales guys. ...

    I received that info from one of our sales guys. We're both a lennox and carrier dealer, and i'm pretty sure we only stock carrier coils. Not 100% sure about that.
  15. Replies
    15
    Views
    5,123

    N-Coil vs A-Coil

    I was doing a residential cooling start-up this week on a Lennox XC-15 410-A system this past week and ran into some problems. Our company replaced the old 5 ton condenser and A-coil last summer...
  16. Replies
    32
    Views
    2,653

    Results

    So I have been back to this site a couple of times since tightening the collar with rotation and the collar is still tight and also the bearing sounds like a new bearing should!!! Thanks for the...
  17. Replies
    8
    Views
    623

    I'm a first refrigeration mechanic and was sked...

    I'm a first refrigeration mechanic and was sked to put the question on the forum by my manager. A couple of the other servicemen have been pulling mice & nests out of the combustion box. The...
  18. Replies
    8
    Views
    623

    The customer lives in an agricultural setting...

    The customer lives in an agricultural setting where he would need several cats. Is there a type of screen/mesh we can but on the exhaust/intake that won't restrict airflow?
  19. Replies
    8
    Views
    623

    High Efficient Terminations + Rodents?

    Has anyone found a way to keep mice out of the high efficient terminations? I have a furnace that either gets mice in the combustion box or the customer puts a screen on the outside and the furnace...
  20. Replies
    32
    Views
    2,653

    Did a visit today

    So I ended up going with the rotation today, the fan was a lot quieter now. I'll be going back for my weekly walk through on Friday and will inspect it again. I'll post the findings.
  21. Replies
    32
    Views
    2,653

    I changed the bearing about a six weeks ago and...

    I changed the bearing about a six weeks ago and on a walk through today I found that the bearing was pretty loud. I was taking the locking collar off to inspect the shaft and bearing and noticed...
  22. Replies
    32
    Views
    2,653

    Concentric Locking Bearings

    I've been looking for some information on Concentric locking bearings as to which way to turn the locking portion of the bearing, with the rotation of the shaft or against the rotation. Any advice?
Results 1 to 22 of 34
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event