Search:

Type: Posts; User: ruuufuhbock

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    56
    Views
    2,180

    ^^^^^^^^ Sent from my iPhone using Tapatalk

    ^^^^^^^^


    Sent from my iPhone using Tapatalk
  2. Replies
    56
    Views
    2,180

    I'm starting to feel nervous about offering...

    I'm starting to feel nervous about offering advice. What's your background


    Sent from my iPhone using Tapatalk
  3. Replies
    56
    Views
    2,180

    Should be 460 from l1-l2 l2-l3 l1-l3. You may...

    Should be 460 from l1-l2 l2-l3 l1-l3. You may have to ohm the wiring and make sure you don't have a broken wire or something goofy.


    Sent from my iPhone using Tapatalk
  4. Replies
    56
    Views
    2,180

    Sounds like it's single phasing. Bit you need to...

    Sounds like it's single phasing. Bit you need to verify your phase to phase voltage not to ground.
  5. Replies
    4
    Views
    573

    Multiple pumps might be your best bet. General...

    Multiple pumps might be your best bet. General rule is cfm squared is the tonnage your pump is capable of pulling down.


    Sent from my iPhone using Tapatalk
  6. Just don't go too low. Below 250 microns you...

    Just don't go too low. Below 250 microns you start degassing refrigerant oil


    Sent from my iPhone using Tapatalk
  7. Replies
    27
    Views
    2,711

    It's hard to say. Our controls division is all...

    It's hard to say. Our controls division is all guys that are in the local but there are others that use guys that are non Union and I think there are others that have a mix of the two


    Sent from...
  8. Replies
    27
    Views
    2,711

    Love it, was able to jump right into the JAT's....

    Love it, was able to jump right into the JAT's. Training is amazing


    Sent from my iPhone using Tapatalk
  9. Replies
    27
    Views
    2,711

    Congrats! I just got into the 420 about 6 months...

    Congrats! I just got into the 420 about 6 months ago myself


    Sent from my iPhone using Tapatalk
  10. Replies
    27
    Views
    2,711

    Any update? I dont think apprentices can solicit...

    Any update? I dont think apprentices can solicit their own work in the 420 fwiw
  11. Replies
    8
    Views
    1,699

    Are there any performance issues here or you just...

    Are there any performance issues here or you just noticed a big temp drop?
  12. Replies
    57
    Views
    7,176

    I second pulling p8 and using a small t stat...

    I second pulling p8 and using a small t stat screwdriver to short out the terminals and run it through test. I believe if it skips any of the stages it's because of a fault.
  13. Replies
    25
    Views
    3,666

    H10 has worked for me on a lot of different...

    H10 has worked for me on a lot of different refrigerants. 410 included
  14. Replies
    34
    Views
    4,457

    The flux argument is kind of weak..I mean I get...

    The flux argument is kind of weak..I mean I get it and I'm not by rights a stay Brite guy but we use flux when brazing dissimilar metals...hell I've worked with guys who fluxed all their braze...
  15. Replies
    34
    Views
    4,457

    Despite some dudes best efforts I feel that it...

    Despite some dudes best efforts I feel that it will in fact spiral out of control...
  16. Replies
    34
    Views
    4,457

    I actually get excited when changing a txv and...

    I actually get excited when changing a txv and see that it's been soldered with #8. Last one I did had about a grand total of 20 seconds torch time.however I don't think you will have any success...
  17. Replies
    15
    Views
    5,254

    I don't think I would ever leave if I was a...

    I don't think I would ever leave if I was a factory chiller tech lol but different strokes I guess.
  18. Replies
    4
    Views
    861

    Thanks for sharing, we only have one or two...

    Thanks for sharing, we only have one or two reflecs around its always nice to get some more insight, we deal mostly danfoss, some comtrol and a few eil, maybe 2 e2's.
  19. Replies
    13
    Views
    2,156

    Too many, that is until these stores clean cases,...

    Too many, that is until these stores clean cases, then I never have enough! I think we carry 4-5 a.o. smith 9207f2 motors, a bunch of other assorted baseball motors, A bunch of psc motors,and others...
  20. Replies
    4
    Views
    861

    Out of curiosity what ended up being the issue?

    Out of curiosity what ended up being the issue?
  21. Replies
    10
    Views
    2,282

    Never saw hot gas piped to the outlet of EVAP....

    Never saw hot gas piped to the outlet of EVAP. Have always seen it piped in after the TXV and before the distributor as previously stated
  22. Replies
    8
    Views
    1,405

    Just wanted to follow up a little...did as pecmsg...

    Just wanted to follow up a little...did as pecmsg suggested and running well ever since. Thanks again for all the help:cheers:
  23. Replies
    8
    Views
    1,405

    Thanks for the help, I will post a pic tomorrow...

    Thanks for the help, I will post a pic tomorrow but basically picture 2 fans mounted directly to the back wall that are tilted back at the top of the mount to allow air to circulate up and around the...
  24. Replies
    8
    Views
    1,405

    R134a reach in

    Have a 3 door reach in prep table giving me fits. Original call was cooler not making temp. Running at about 44*. Running off of low pressure control. System has a receiver, sight glass is full. Back...
  25. .

    .
  26. Replies
    27
    Views
    3,359

    Olive bars are hell on coils and power heads too,...

    Olive bars are hell on coils and power heads too, as already said I was told its from the acid.
  27. Mike, The answer is the second to last paragraph

    Mike, The answer is the second to last paragraph
  28. Replies
    61
    Views
    6,944

    3 years of high school French and all I can pick...

    3 years of high school French and all I can pick out is something you French something. Maybe something something....public education at its finest!
  29. Replies
    61
    Views
    6,944

    I'm going to piggy back a little and say French...

    I'm going to piggy back a little and say French Canadian, I saw an "eh" in a post earlier
  30. Replies
    61
    Views
    6,944

    I'm glad I'm not the only one having a hard time...

    I'm glad I'm not the only one having a hard time following these posts :grin2:
  31. Replies
    15
    Views
    2,136

    392311 Here's a pic of a suction drier that had...

    392311
    Here's a pic of a suction drier that had a 40 psi drop across it! I have a feeling that this compressor will be done pumping its crap soon.:grin2:
  32. length of time for ice machine cleanings

    Just wanted to get some opinions about how long it should take to clean and sanitize a follet countertop nugget ice machine. Can post model number if it would help, but just looking for some general...
  33. Replies
    14
    Views
    3,212

    Could be improperly solenoid sized also,...

    Could be improperly solenoid sized also, oversized valve will cause similar situation
  34. Replies
    9
    Views
    1,430

    Have you checked your line voltage? If I remember...

    Have you checked your line voltage? If I remember correct that would be a good place to start.
  35. Replies
    2
    Views
    669

    It's what makes time travel possible!!

    It's what makes time travel possible!!
  36. Replies
    25
    Views
    7,990

    Just got a quote for 14oz of r290 it was over...

    Just got a quote for 14oz of r290 it was over 500$ think id just use 22, I thought it was for oil return on ultra low systems?
  37. Any other readings like SH and sc, anything and...

    Any other readings like SH and sc, anything and everything you've got will be helpful
  38. Good point about no diy, I agree that its...

    Good point about no diy, I agree that its impossible to make a good diagnosis will out a full set of readings. sorry if it seemed like I was jumpin down your throat! Welcome to the forum BTW
  39. We protect it by keeping it cool and ensuring...

    We protect it by keeping it cool and ensuring that no liquid returns, I'm just saying with a reefer system charging it by checking compressor sh is a poor practice. I'm not saying it shouldn't be...
  40. Man can't believe I missed that! Maybe in the aop...

    Man can't believe I missed that! Maybe in the aop roe v wade section
  41. Crossthread- you are talking about sh taken at...

    Crossthread- you are talking about sh taken at the evap, which is how it should be set on reefer system. Copeland cares about comp protection.
  42. Replies
    31
    Views
    10,258

    Beware, service experts apparently is getting in...

    Beware, service experts apparently is getting in to chillers, in se pa anyhow. Had a customer call them out for a second opinion on a York screw chiller, I just Hung my head and started praying...
  43. Replies
    22
    Views
    7,333

    I'm on the "inducer needs to be replaced"...

    I'm on the "inducer needs to be replaced" bandwagon. Seen this a few times. If you do a search on here you'll see a ton of threads about this.
  44. Replies
    57
    Views
    10,004

    10-12 degrees sh at evaps for cooler or freezer...

    10-12 degrees sh at evaps for cooler or freezer is very high imo. Freezer I usually set around 6. And as said before if system has a reciever I don't worry about sc.
  45. Replies
    28
    Views
    3,826

    The real way to set a pump down system is to make...

    The real way to set a pump down system is to make sure that your pumpdown psi converted to saturated temp is lower than the lowest ambient temp your condenser will see. Imo... Also did you set your...
  46. Replies
    12
    Views
    2,198

    I'll wear it underneath the collared shirt at all...

    I'll wear it underneath the collared shirt at all times like superman
  47. Replies
    12
    Views
    2,198

    I might even have a tee shirt made to mark the...

    I might even have a tee shirt made to mark the occasion!
    :cheers:
  48. Replies
    12
    Views
    2,198

    Wow I finally got one!!! Lol bottoms up tonight!!

    Wow I finally got one!!! Lol bottoms up tonight!!
  49. Replies
    12
    Views
    2,198

    Is this one of the units.where the HP switch is...

    Is this one of the units.where the HP switch is on an angle valve that needs to stay a crack open? I've seen that happen a lot where people close that valve and this happens.
  50. Replies
    18
    Views
    2,955

    I have to cast my vote for the h10, if you know...

    I have to cast my vote for the h10, if you know how to use it it can do some amazing stuff
Results 1 to 50 of 210
Page 1 of 5 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.