Search:

Type: Posts; User: Tta197

Search: Search took 0.00 seconds.

  1. Carrier/Bryant blower on after power up code 12

    Carrier/Bryant:"blower on after power up code 12", is this a real problem or just nuisance fault? Furnace is a 90i Evolution. Two events recorded since the start of the new year. Thank you in...
  2. Replies
    44
    Views
    2,284

    Tedkidd, that's a good idea. I'll have to look...

    Tedkidd, that's a good idea. I'll have to look into it because the heat pump I currently have is a p.o.s. in my opinion anyway.
  3. Replies
    44
    Views
    2,284

    Yes, I'll be be dealing with the same problem. ...

    Yes, I'll be be dealing with the same problem. This just buys me time so I can get it fixed.
    I thought the same thing about how dirty the blower looked. The only thing I can figure is I was using a...
  4. Replies
    44
    Views
    2,284

    Tedkidd, I was able to lock on low heat through...

    Tedkidd, I was able to lock on low heat through the thermostat. Thanks for the tip.
  5. Replies
    44
    Views
    2,284

    I don't have a manometer. I'm just going by what...

    I don't have a manometer. I'm just going by what the thermostat reads. Keep in mind I don't do hvac for a living, although after all the b.s. I've experienced with this house I won't be fooled again...
  6. Replies
    44
    Views
    2,284

    Rodney, Yes I would header the two 2x6's and I'm...

    Rodney,
    Yes I would header the two 2x6's and I'm thinking I'll just have the left side pull air from the 1st floor (along with that 1st fl bedroom) and the existing return plenum will pull its air...
  7. Replies
    44
    Views
    2,284

    Output Btu is 73000 for low Input Btu is 78000...

    Output Btu is 73000 for low
    Input Btu is 78000 for low
    Output Btu is 113000 for high
    Input Btu is 120000 for high

    bryant furnace 355aav060120

    I agree this beast seems to be happy on low...
  8. Replies
    44
    Views
    2,284

    .50 with filter removed but door back on....

    .50 with filter removed but door back on.
    Needless to say I have to keep a clean filter on this system or else the thermostat will let know it's not happy.

    Your typical home owner would never...
  9. Replies
    44
    Views
    2,284

    Tedkidd, you said to lock on low. Is this...

    Tedkidd, you said to lock on low. Is this something I can do at the thermostat? It typically runs on low heat except when I do three degree setback. When it kicks on in the morning to recover the...
  10. Replies
    44
    Views
    2,284

    The air coming in from the bottom is filtered. It...

    The air coming in from the bottom is filtered. It comes from the return plenum through the filter and the furnace sits on a 5 1/2" high square metal box which I was told would simulate air being fed...
  11. Replies
    44
    Views
    2,284

    I've done it before and it was definitely a...

    I've done it before and it was definitely a return problem.

    I do remember the techs installing the furnace telling me that the reason they used that 5 1/2" tall box the furnace sits on, was so...
  12. Replies
    44
    Views
    2,284

    Left side of furnace.

    Left side of furnace.
  13. Replies
    44
    Views
    2,284

    High heat/high blower: static pressure is .50...

    High heat/high blower: static pressure is .50 without the filter installed.
    Does this mean the duct work is adequate and choking point is at the blower?
  14. Replies
    44
    Views
    2,284

    1hp blower motor picture.

    1hp blower motor picture.
  15. Replies
    44
    Views
    2,284

    Yes, they installed it to help the blower.. I...

    Yes, they installed it to help the blower.. I think the installers did this to avoid adding a second return on the other side of the blower.

    Static pressure does drop without the filter in as it...
  16. Replies
    44
    Views
    2,284

    Yes, one more filter rack. The furnace already...

    Yes, one more filter rack. The furnace already sits 5 1/2" off the floor because it sits on a square metal box.
  17. Replies
    44
    Views
    2,284

    There's a storage room on the left side of the...

    There's a storage room on the left side of the furnace. You're looking at a studded wall separating the storage rooms. I would have to do something with 2x6 studs as they are load bearing. There are...
  18. Replies
    44
    Views
    2,284

    Vstech: The furnace does sit on a 5 1/2" tall...

    Vstech: The furnace does sit on a 5 1/2" tall square duct to help the blower sick air. I was told that's why it sits on the ductwork.

    Sorry for the rotated picture. I'm not sure why it keeps doing...
  19. Replies
    44
    Views
    2,284

    I could maybe feed one side of the blower with...

    I could maybe feed one side of the blower with the 1st floor duct work and leave the other side fed by the 2nd floor alone.

    Thoughts?
  20. Replies
    44
    Views
    2,284

    I've been told the blower would thank me if I...

    I've been told the blower would thank me if I added another return on the other side of the blower.
    I do have a bedroom on the 1st floor without a return in it (room is comfortable) that I could...
  21. Replies
    44
    Views
    2,284

    One more picture.

    One more picture.
  22. Replies
    44
    Views
    2,284

    The return duct measures 14x25. The 1st floor...

    The return duct measures 14x25. The 1st floor return uses the floor joints for about 4 feet after it makes a 90 degree bend. Does this affect air flow?
    Sorry for the poor picture.
  23. Replies
    44
    Views
    2,284

    Bryant evolution high static pressure

    I have a Bryant Evolution furnace with the evolution control thermostat. Is the static pressure of .38 for low heat and .89 for high heat normal?

    I'm using a merv 8 20x25x5 filter.

    This is a...
  24. Really? I wasn't aware of this. OK then I'll get...

    Really? I wasn't aware of this. OK then I'll get rid of the Honeywell thermostat with its OAT sensor. Thanks!
  25. Will a Honeywell OAT sensor work with Evolution/Infinity control?

    I am planning on having my Honeywell Visionpro replaced by an Evolution/Infinity control and was told that my current Honeywell OAT sensor will work with a NIM. Is this true?
    Fyi: my furnace is an...
  26. Replies
    5
    Views
    1,181

    Ok, I'll give it a try. Thanks!

    Ok, I'll give it a try. Thanks!
  27. Replies
    5
    Views
    1,181

    Thanks for the reply to both of you. What cph do...

    Thanks for the reply to both of you. What cph do guys recommend? Or is this something that is just personal taste?
  28. Replies
    5
    Views
    1,181

    Honeywell vision pro thermostat?

    Can I control the temperature swing on this thermostat? I would like a 1 or 2 degree temp. swing. I don't think this thermostat will let me do that.

    Would the evolution control thermostat be...
  29. Solved my problem with window condensation. I had...

    Solved my problem with window condensation. I had a 12 inch cold air return in the basement. I've seen this done in numerous newer homes (well maybe not as big as 12 inches of cold air return) so I...
  30. I don't have condensation in between the panes....

    I don't have condensation in between the panes. It's on the inside pane, at the bottom two to three inch mark.
    Thanks for everyone's input.
  31. I'm hoping it's not the windows, but that's what...

    I'm hoping it's not the windows, but that's what I was putting the blame on. I'll try to experiment with the fresh air idea and go from there.
    Thanks to everyone who replied.
  32. I currently don't have a Hrv. I'll have to...

    I currently don't have a Hrv. I'll have to research what model to get etc...
    In the mean time I might try what George suggested and bring in fresh air directly to the cold air return with a damper. ...
  33. Teddy, Do I need to address the air inlet to...

    Teddy,
    Do I need to address the air inlet to furnace so that it's sucking outside air or is that over kill? It would be a bit of a pain to drill thru my rim joist because the house is all brick. So...
  34. All the windows have wood blinds that are left...

    All the windows have wood blinds that are left open except in the bedrooms. I can see the bedroom windows sweating but I have a problem with rest of the windows. I even raise the blinds that are left...
  35. No humidifier anywhere in the house. I run a...

    No humidifier anywhere in the house. I run a dehumidifier in the basement set at 45% which runs all the time until the outside temps get in the 20's. Then it will shutoff.
  36. Condensation on windows only w/ temps 20F or lower

    Greetings,
    I'm getting condensation on all my dual pane wood casements when the outside temp. is 20F degrees or lower. Otherwise the windows stay dry. The humidity in the house is 35% to 38%. This...
Results 1 to 36 of 36
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event