Search:

Type: Posts; User: timberlinemd

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    16
    Views
    1,151

    Get another tank, put it in a vacuum when time...

    Get another tank, put it in a vacuum when time permits. Use the vacuumed tank to pull out most of the ref, then recover. Big time saver. When you got time transfer ref into another tank, repeat.
  2. Replies
    27
    Views
    1,676

    Used to be I would make a real stink about how...

    Used to be I would make a real stink about how hard I had to work for the money these 'bums' wanted me to give them for doing nothing. Always told them to 'get lost'.

    Lately, I'm been thinking how...
  3. Replies
    91
    Views
    7,907

    Impressive! Thanks for the printout.

    Impressive!

    Thanks for the printout.
  4. Replies
    91
    Views
    7,907

    So, do I call the system charge OK, because the...

    So, do I call the system charge OK, because the delta T is good, and move on?
  5. Replies
    91
    Views
    7,907

    Checked a 3-1/2 ton Goodman 13 SEER heat pump...

    Checked a 3-1/2 ton Goodman 13 SEER heat pump today. Fixed orifice.

    Air supply 1425 CFM

    Return 76*DB/55*WB
    Supply 55*DB
    Delta T 21*
    ID RH 25%

    OT 93*
  6. Any more than 6 SF. A return register would get...

    Any more than 6 SF. A return register would get you there before cutting in any supplies.
  7. EPA - Lead Renovation, Repair and Painting Rule

    Anyone get certified for this?
    I've turned down two new installs quotes, because I chose not to become certified. Cutting in ducts in pre '78 homes would require certification and following the...
  8. He said the furnace blower does not run. :whistle:

    He said the furnace blower does not run. :whistle:
  9. In that case the AC would be a entirely separate...

    In that case the AC would be a entirely separate system, possibly sharing the same duct work.

    I was trying to determine if the "AC condenser" is what I refer to as a 'park model', cooling only....
  10. Does the AC condenser look like a package unit or...

    Does the AC condenser look like a package unit or do you see refrigerant lines going under the home?
  11. Older manufactured homes came with heat only. AC...

    Older manufactured homes came with heat only. AC had to be added by third party. Sounds like the two wire thermostat is heat only. You didn't say if this has a gas or electric furnace? If the AC was...
  12. Replies
    24
    Views
    1,435

    Changed motor to 825 rpm and all is well.

    Changed motor to 825 rpm and all is well.
  13. Replies
    24
    Views
    1,435

    Cleaned.

    Cleaned.
  14. Replies
    24
    Views
    1,435

    The fan blade is still OEM. Which I assume would...

    The fan blade is still OEM. Which I assume would be sized for the OEM motor which is 1/4 hp 850 rpm.
  15. Replies
    24
    Views
    1,435

    I believe I have realized my own downfall with...

    I believe I have realized my own downfall with your guys help. With OEM blade pitch...

    Faster rpm = more air movement = more load on the motor = temperature rise of motor = thermal shutdown (1/4hp...
  16. Replies
    24
    Views
    1,435

    Dennis, looks like the OEM motor was 850 rpm....

    Dennis, looks like the OEM motor was 850 rpm. Will a 825 rpm motor solve the problem?
  17. Replies
    24
    Views
    1,435

    That is my guess. Made in China. Isn't...

    That is my guess. Made in China. Isn't everything. Right now I'm thinking of another brand motor to purchase Monday. Any recommendations on manufacturer?
  18. Replies
    24
    Views
    1,435

    York model E1RD060S06A. Do not know if OEM is 800...

    York model E1RD060S06A. Do not know if OEM is 800 rpm. Anywhere to find out?
  19. Replies
    24
    Views
    1,435

    yes.

    yes.
  20. Replies
    24
    Views
    1,435

    Did not replace cap. Checked cap with cap tester....

    Did not replace cap. Checked cap with cap tester. 5.7 mfd tested for a 5 mfd cap.
  21. Replies
    24
    Views
    1,435

    Condenser Fan Motor Thermals out

    I'm servicing a 8 year old, 5 ton condenser (York split heat pump). I've replaced the original condenser fan motor about 2 years ago. A month ago I have to replace that motor. Now, that motor is...
  22. I just use my construction calculator. Enter run,...

    I just use my construction calculator. Enter run, rise and get diagonal. Add (*) room length = SF of ceiling. Your method is good for Cu Ft of room (width * length * 10').
  23. Replies
    8
    Views
    572

    Thanks!

    Thanks!
  24. Replies
    81
    Views
    7,433

    I mostly forget to reset the thermostat after I...

    I mostly forget to reset the thermostat after I have finished a diagnostic.
    :whistle:I'm getting better though.
  25. Replies
    81
    Views
    7,433

    Ditto! :)

    Ditto! :)
  26. Replies
    8
    Views
    572

    Sound like this is done with a running...

    Sound like this is done with a running compressor.
    I would like to know if it is OK to charge thru the suction and liquid line at the same time when the compressor is NOT running.
  27. Replies
    8
    Views
    572

    Charging by liquid/Best practice

    This forum has a wealth of knowledge, and I haven't even been allowed into the 'pro' section yet.

    After an evacuation and charging by weight, is it OK to charge 85%-90% by liquid through the...
  28. Replies
    20
    Views
    1,443

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  29. Replies
    17
    Views
    1,923

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  30. Replies
    12
    Views
    1,453

    Not 'frequent' :whistle:

    Not 'frequent' :whistle:
  31. Replies
    12
    Views
    1,453

    I'm here in south central Arizona. I just did a...

    I'm here in south central Arizona. I just did a manual J using a couple of different programs and they are saying that my house has a heat gain of around 19k-20k BTUPH.
    I have a Goodman 4-ton heat...
  32. Replies
    71
    Views
    8,506

    At the current price for copper, where's that...

    At the current price for copper, where's that 40'?.

    I'm bringing my tubing cutter and torch. :grin2:
  33. Replies
    42
    Views
    3,763

    Got a Fieldpiece pocket digital psychrometer from...

    Got a Fieldpiece pocket digital psychrometer from my supplier today for $60!
  34. I stand corrected. 410a is considered an...

    I stand corrected.
    410a is considered an azeotropic and not a zeotropic. The chemical composition should not separate easily.

    However, we are told to charge as a liquid. That would suggest that...
  35. Replies
    28
    Views
    2,698

    My thoughts, are I decide on a case by case...

    My thoughts, are I decide on a case by case bases.

    I always recommend that they pay me to find the leak, and if it is fixable to pay me to do that also. The push back comes from the fact that the...
  36. Replies
    16
    Views
    1,073

    I'd try the proper sized 'hard start' cap/relay...

    I'd try the proper sized 'hard start' cap/relay to give it a 'kick'.
  37. Replies
    3
    Views
    323

    Have him check if there is low voltage entering...

    Have him check if there is low voltage entering the defrost board? Then is it coming out to the contactor? If no voltage coming in, jump the hot (red) wire and contactor (yellow) wire at thermostat....
  38. Another bit of info for anyone trying to recover...

    Another bit of info for anyone trying to recover a refrigerant that has been subjected to a 'leak seal'. Because of the nature of the 'leak seal' product, if any air/moister is allowed to enter into...
  39. To my knowledge, no manufacturer will allow a...

    To my knowledge, no manufacturer will allow a 'leak seal'. Using it will void any warranties on equipment.
  40. Yes, because it is a blend you are not suppose to...

    Yes, because it is a blend you are not suppose to 'top off'.
Results 1 to 40 of 57