Search:

Type: Posts; User: cororumrex

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    10
    Views
    716

    Are you measuring the temperatures at the supply...

    Are you measuring the temperatures at the supply and return vents or at the equipment. You will be able to tell if it is the ductwork by comparing the temperature at the vents and the temperature at...
  2. I usually recommend replacement of the boiler...

    I usually recommend replacement of the boiler with a high efficiency system.

    Some of the things you are being told are true.

    When you convert a oil burner to a gas burner you lose efficiency.
    ...
  3. Replies
    10
    Views
    716

    Usually 20 degree delta T (temperature...

    Usually 20 degree delta T (temperature difference) is what we look for. So if the Return Air going back to the system is 90 then the air coming out of the system should be 70.

    The Return air...
  4. Replies
    8
    Views
    941

    I think your contractor should of at least...

    I think your contractor should of at least offered to perform a leak search to identify if you have a leak and where it would be. Typically this is at an extra cost. But if a 3 year old system needs...
  5. Replies
    19
    Views
    2,219

    I would agree with most of what everyone is...

    I would agree with most of what everyone is saying except for the advice on the sizing. First question is...
    How did all the contractors arrive at the 2.5 or 3 Ton size?
    Did they do a Manual J load...
  6. Replies
    9
    Views
    920

    Tom, I personally would go with the EcoBee. I...

    Tom,

    I personally would go with the EcoBee. I have one in my home and have installed around 10-15 for customers. I have also installed a bunch of the TRANE HD stat. Both are great products.
    ...
  7. Replies
    9
    Views
    2,048

    Yeah they might need that color if they do some...

    Yeah they might need that color if they do some touch ups.
  8. Replies
    9
    Views
    2,048

    Ye Old Paint Can Water Heater Vent Pipe

    Ran a sales call to replace a boiler with flood damage. Found this nice new venting product being used. I think this may be the future of water heating venting.

    Jordan
  9. I would agree with Gross, We use rotobrush and i...

    I would agree with Gross, We use rotobrush and i works well, the main thing is that is has a camera attached to the brushhead so we can actually see whats going on.

    Jordan
  10. Replies
    12
    Views
    1,295

    The Trane System is a pretty nice system. That is...

    The Trane System is a pretty nice system. That is what the compnay I work for installs. I did notice that one of the model match ups they are provided dont have an AHRI match.

    The 2 Ton System...
  11. Replies
    24
    Views
    1,481

    To be honest I dont think I know who our Rep...

    To be honest I dont think I know who our Rep is... I have worked with Brett on solar stuff and talked to Dave M. about some stuff. Theres inside office people who handle most that stuff.
    Jordan
  12. Replies
    24
    Views
    1,481

    Do you work for HVAC by chance?

    Do you work for HVAC by chance?
  13. Replies
    24
    Views
    1,481

    Take a look at the Apricus system. Our Dist is...

    Take a look at the Apricus system. Our Dist is HVAC out of Mt joy PA.
  14. Replies
    13
    Views
    937

    Moto, Have you heard anything about if variable...

    Moto,
    Have you heard anything about if variable speed motors will have any tax incentive attached to them?
    J
  15. Replies
    13
    Views
    937

    Moto, thats fine, I figured you knew. Just got...

    Moto, thats fine, I figured you knew. Just got numbers mixed up. Its easy to do with all these different programs.

    We are finding in alot of situations its cheaper to do a heatpump rather then try...
  16. Replies
    13
    Views
    937

    The qualifications for heat pumps are 8.5 HSPF 15...

    The qualifications for heat pumps are 8.5 HSPF 15 SEER and 12.5 EER.

    Jordan
  17. I agree, Customers typically get a better ROI on...

    I agree, Customers typically get a better ROI on sealing and insulating then high efficiency equipment. And if they do that first we can often times downsize equipment even further.

    J
  18. I Close on average 15 - 20 per month, my close...

    I Close on average 15 - 20 per month, my close percentage is a solid 30%. I do pretty well for myself. and I know my commission scale is average for replacement sales...

    And it is probably only...
  19. I do Manual J on about 90% of the jobs I go on....

    I do Manual J on about 90% of the jobs I go on. An average sized home, that is pretty square takes me about 20 minutes - 30 minutes. Thats computer time. I check insulation and windows as I walk...
  20. Replies
    32
    Views
    7,430

    Or wait for the TXV to stick open, or wait for...

    Or wait for the TXV to stick open, or wait for the 6 Ton reversing valve on a 2 ton 16i to not reverse.
  21. Replies
    98
    Views
    16,682

    I like that you left the xr14 label on the...

    I like that you left the xr14 label on the outdoor unit. I am guessing he was told he was getting the xr14? and got the xb instead?
  22. Replies
    18
    Views
    1,668

    No problem, I just gave it to the HR department.

    No problem, I just gave it to the HR department.
  23. Replies
    39
    Views
    2,112

    We have slowed, but are keeping pretty busy...

    We have slowed, but are keeping pretty busy still. I am a salesman so my salary is directly effected by slow downs. It happens every year. I do know when I first started out in HVAC and I was with a...
  24. Replies
    18
    Views
    1,668

    717-625-7594

    717-625-7594
  25. Replies
    18
    Views
    1,668

    ok well if you are interested, I posted our...

    ok well if you are interested, I posted our website on your profile.
    Jordan
  26. Replies
    18
    Views
    1,668

    We are hiring for Commercial HVAC service,...

    We are hiring for Commercial HVAC service, Install, & Electricians. And I think a HVAC residential service tech. We cover Lancaster, Harrisburg, York, Lebanon, Berks, and a bit of Chester county. Our...
  27. Replies
    38
    Views
    6,047

    tpiovoso, Do you have any fireplaces that are...

    tpiovoso,

    Do you have any fireplaces that are used in the home?
    What is your average ceiling height?
  28. Replies
    9
    Views
    4,666

    not yet, last I spoke with him he was waiting...

    not yet, last I spoke with him he was waiting until march until he gets his home refinance in order.
  29. Replies
    9
    Views
    4,666

    I think I was the Trane guy who quoted this.

    I think I was the Trane guy who quoted this.
  30. You from the south? All we use, all anyone uses...

    You from the south? All we use, all anyone uses in our area is duct board. Well most the time. If you have a customer from florida they always want metal.
  31. Replies
    13
    Views
    1,847

    Both of the manufactures we are looking at use a...

    Both of the manufactures we are looking at use a single tank design. There is two separate t-stats in the tank. And I think it is pretty closely regulated. The pump system is also on a t-stat so if...
  32. Replies
    13
    Views
    1,847

    We deal Quietside and Prestige also. I actually...

    We deal Quietside and Prestige also. I actually just did a job that has solar in mind. I installed a Prestige Solo 110 and an Oventrop indirect tank that is built for the oventrop solar domestic...
  33. Replies
    9
    Views
    1,242

    In regards to a duel fuel setup with the vision...

    In regards to a duel fuel setup with the vision pro. The Vision pro will operate off of a "droop and a set back temp. So if the heatpump is running and the temperature starts dropping the visionpro...
  34. I have installed about 50-60 TCE in homes in the...

    I have installed about 50-60 TCE in homes in the last two years. I have had one problem with a customer complaining of a dry feeling, and an irritating odor after the CleanEffects was installed. We...
  35. Thread: Amazing

    by cororumrex
    Replies
    9
    Views
    1,596

    That would be terrifying.

    That would be terrifying.
  36. Replies
    8
    Views
    2,024

    I just put a downflow geothermal in an earth...

    I just put a downflow geothermal in an earth sheltered home. The utility room is a little building on top of the house. Pretty cool setup. Did an Trane ERV and a climadry coil with it to dehumidify...
  37. Thread: Amazing

    by cororumrex
    Replies
    9
    Views
    1,596

    You ever see "Myth Busters" when they blew up the...

    You ever see "Myth Busters" when they blew up the water heater by closing off the Relief valve and disabling the high limit?

    I wonder if that could happen with a boiler?

    Click here to see if...
  38. Thats the direction I was headed in, dident know...

    Thats the direction I was headed in, dident know if it could be a straight Unico Heatpump, Or a Unico A/c with Hot watercoil. Was waiting to see more pictures.
  39. Looks like a High Velocity System. Unico or...

    Looks like a High Velocity System. Unico or Spacepak, I would need more info pictures of equipment, model numbers to tell you more.
  40. Thats odd, I dont know why you all cant see it....

    Thats odd, I dont know why you all cant see it. Is there another way to post pictures?
  41. No the flow center is on the wall under the...

    No the flow center is on the wall under the expansion tank. Is that what you are talking about?
  42. ClimateMaster Tranqulity 27 Geothermal Install

    http://picasaweb.google.com/cororumrex/GeothermalSystem#5259618926250378274

    Pretty nice Geothermal Install one of my best installers did.
  43. Replies
    12
    Views
    1,781

    Are you using a micron gauge?

    Are you using a micron gauge?
  44. Replies
    9
    Views
    4,817

    Be careful with the heatpump model of the 19i it...

    Be careful with the heatpump model of the 19i it is difficult to get above 17 SEER, most situations you will get 16 to 16.5 SEER. The same might hold true with the infinity, I sell Trane. I prefer...
  45. Replies
    339
    Views
    45,746

    Lancaster, Pennsylvania. I do Residental...

    Lancaster, Pennsylvania. I do Residental replacment sales.
  46. Replies
    24
    Views
    120,091

    I have also heard you can drive by the building...

    I have also heard you can drive by the building at 15 M.P.H. and count. However many seconds you get is your tonnage.

    _J_
  47. Replies
    32
    Views
    1,969

    We have put alot of them in. And most homeowners...

    We have put alot of them in. And most homeowners seem to be pleased with them. Our service technicians are not crazy about them. But I think that may be partly because of the recall on them earlier...
  48. I would agree with twilli, I think closed loop...

    I would agree with twilli, I think closed loop are better just for there longevity. I usually see systems replaced at 15 years with open loop and closer to 20 years with closed.

    I definitively...
  49. Replies
    70
    Views
    4,285

    True, they are also built better then they were...

    True, they are also built better then they were even 10 years ago. Most of the lifetime warranties I have seen are limited though to. So they are only good for the purchasing home owner. And I am...
  50. Replies
    70
    Views
    4,285

    All new furnaces have high limit switches which...

    All new furnaces have high limit switches which will keep them from getting dangerously hot. It is the constant heating and cooling (Expanding/ contracting) that will weaken the metal of the heat...
Results 1 to 50 of 60