Search:

Type: Posts; User: 37bluebird

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    18
    Views
    587

    M series uses 14/3 with ground and P series is...

    M series uses 14/3 with ground and P series is 16/3 with ground.


    Sent from my iPad using Tapatalk
  2. Replies
    4
    Views
    1,605

    Sent you a text Sent from my iPad using...

    Sent you a text


    Sent from my iPad using Tapatalk
  3. Replies
    87
    Views
    12,719

    I will sell you my HG3 like new condition. $200 ...

    I will sell you my HG3 like new condition. $200


    Sent from my iPad using Tapatalk
  4. Replies
    87
    Views
    12,719

    I have seen the release date is April 1. ...

    I have seen the release date is April 1.


    Sent from my iPhone using Tapatalk
  5. Replies
    4
    Views
    1,605

    Still have this and would like to get rid of it....

    Still have this and would like to get rid of it. $200 shipped my lose your gain.


    Sent from my iPhone using Tapatalk
  6. Replies
    35
    Views
    4,866

    552831 Sent from my iPad using Tapatalk

    552831


    Sent from my iPad using Tapatalk
  7. Replies
    35
    Views
    4,866

    It works pretty good I've used mine a few times...

    It works pretty good I've used mine a few times to adjusted airflow.


    Sent from my iPad using Tapatalk
  8. Replies
    70
    Views
    8,311

    Calling all Bryant / Carrier Guys

    Ran into my first one giving me this problem at 11pm last night. I large the hole on inducer and haven't heard back from them yet. If I get called back looks like I will replace inducer and control...
  9. Replies
    10
    Views
    730

    Carr supply $40 Sent from my iPhone using...

    Carr supply $40


    Sent from my iPhone using Tapatalk
  10. Replies
    10
    Views
    730

    Just bought one today to try out. 542101 ...

    Just bought one today to try out. 542101


    Sent from my iPhone using Tapatalk
  11. Biggest thing is won't dim the lights when...

    Biggest thing is won't dim the lights when compressor starts.


    Sent from my iPhone using Tapatalk
  12. Thread: H10 PM

    by 37bluebird
    Replies
    8
    Views
    1,718

    Can you send me pics unable to send pm. Sent...

    Can you send me pics unable to send pm.


    Sent from my iPad using Tapatalk
  13. They make a kit for this problem. Easy fix do it...

    They make a kit for this problem. Easy fix do it all the time but can't remember what the kit is called.
  14. Thread: Wages

    by 37bluebird
    Replies
    149
    Views
    22,805

    I've been in the field for 15yrs been with same...

    I've been in the field for 15yrs been with same company for 10 as a res. light comm. service tech. I'm making 18 an hr here in ohio.
  15. Thread: Bryant txv

    by 37bluebird
    Replies
    188
    Views
    20,814

    Have to replace one tomorrow unit was installed...

    Have to replace one tomorrow unit was installed about a month ago. Will be the second one this summer. Haven't had any problems with. The bigger units yet.
  16. Replies
    5
    Views
    465

    Why wouldn't you call technical and talk to...

    Why wouldn't you call technical and talk to someone from carrier while your at the job site. I work on Bryant and they don't have that feature which I'm glad heard of a lot of calls about the energy...
  17. Replies
    30
    Views
    2,466

    I thought checking MV across the contacts was...

    I thought checking MV across the contacts was going to be the best and easiest way to check contactors until today. Installed a brand new contactor had 200mv across contactor which to me would be a...
  18. Replies
    30
    Views
    2,466

    So would checking MV across the contactor be a...

    So would checking MV across the contactor be a honest check 75mv and higher replace 70mv and lower call it good? I've never seen a full volt drop across any contact.


    Sent from my iPhone using...
  19. Replies
    30
    Views
    2,466

    When to replace a contactor on a PM call?

    I've been in hvac service for 15 yrs and never really found a great way to check a contactor and figure when it is time to replace. I've been checking MV across the contact which seems to be around...
  20. Replies
    1,077
    Views
    114,075

    I tried out a set of imanifolds today. Couldn't...

    I tried out a set of imanifolds today. Couldn't get though the front door of the house without losing connection only about 10 ft from the outdoor unit. Am I doing something wrong thought the range...
  21. Replies
    4
    Views
    1,605

    Posted on eBay 481991

    Posted on eBay
    481991
  22. Replies
    4
    Views
    1,605

    Feildpiece HG3 for sale

    Looking to sell my barely used HG3. It is in very good working order.
    Comes with
    HG3
    Install disc and instruction

    Asking $300
    Will add pics tonight.
  23. Replies
    1,077
    Views
    114,075

    Wondering if or when the wireless sensor will be...

    Wondering if or when the wireless sensor will be coming out.
  24. Replies
    13
    Views
    2,879

    Wow I'm speechless.

    Wow I'm speechless.
  25. Replies
    1,077
    Views
    114,075

    I'm curious how the indoor wet bulb dry bulb...

    I'm curious how the indoor wet bulb dry bulb sensor looks like. Loving this tool can't wait to get one. Does this manifold come with all the sensors to make all the readings at real time. Or are...
  26. Yep replace pressure switches and check...

    Yep replace pressure switches and check condensate trap for PVC shavings.
  27. Thread: Jobs

    by 37bluebird
    Replies
    9
    Views
    938

    Is this UNOH you a going to. I went there about...

    Is this UNOH you a going to. I went there about 10 yrs ago learned a lot but nothing beats on the job experience.
  28. Replies
    58
    Views
    5,854

    I would say that is pretty good. No one likes...

    I would say that is pretty good. No one likes being on call it sucks but it is apart of the job so get used to it. We get paid only if we get called out min. Of 2hrs so I basically sit around the...
  29. Replies
    13
    Views
    1,846

    I would start with the board.

    I would start with the board.
  30. Replies
    13
    Views
    1,846

    In 2004-06 had a lot of bad relays on the control...

    In 2004-06 had a lot of bad relays on the control board causing this fault. What year is this furnace.
  31. Replies
    26
    Views
    3,925

    Yeah it was my last call took me an hour just to...

    Yeah it was my last call took me an hour just to replace HSI because inside gas line and valve are on top of ignitor screws. And back starts killing you standing awkward just to see what you are...
  32. Replies
    26
    Views
    3,925

    You kidding me

    Have a apartment complex and this is how must of the furnaces are installed I guess the installer knew he would never have to fix these things. I get pissed every time I try and work on one. Have to...
  33. Replies
    32
    Views
    1,733

    What is you pressure of the bladder in expansion...

    What is you pressure of the bladder in expansion tank. Also check the pressure of the system with another gauge and attach it at the boiler drain. Can't tell you how many pressure gauges I find off...
  34. Replies
    11
    Views
    859

    I agree I would going with the focus pro 6000...

    I agree I would going with the focus pro 6000 with wifi. I loved mine but got a new system that had to use the Bryant connex stat. Wish I still could use the 6000.
  35. Replies
    36
    Views
    7,523

    This sounds exactly like my problem. I used the...

    This sounds exactly like my problem. I used the LC back pack for 5 yrs and wore it out so bought a new one. Then started having back pains so thought it might be the bag. Started using smaller bags...
  36. Thread: Fieldpiece

    by 37bluebird
    Replies
    2
    Views
    521

    I would sell my hg3 only used 10 times or so....

    I would sell my hg3 only used 10 times or so. $300 for HG3, CD, USB cable.
  37. Replies
    19
    Views
    1,948

    I have the same problem with spiders. But the...

    I have the same problem with spiders. But the ones I've seen with spider webs the flame just doesn't get hot enough to prove flame. His problem sounds to me has a recirc problem hole in exhaust pipe...
  38. Replies
    19
    Views
    1,948

    I had the same issue and this is what I found on...

    I had the same issue and this is what I found on the roof. 442871
  39. Replies
    50
    Views
    6,403

    That is the nature of the beast. One of my...

    That is the nature of the beast. One of my favorite furnaces to work on.
  40. Replies
    9
    Views
    909

    I believe the fan runs all the time in heat or...

    I believe the fan runs all the time in heat or cool mode to move air across the sensor inside the unit so it knows the room temp. Tstat doesn't really tell the unit the temp of room the sensor inside...
  41. Replies
    49
    Views
    4,026

    Speed vs Thoroughness

    I take an average of a hour on each call if it is a easy fix or a pm call. I ran about 7 calls a day so if I would take longer then that on the easy ones I would never get off work. And only having...
  42. Replies
    12
    Views
    2,279

    I ran furnace for 30min blocked basement door...

    I ran furnace for 30min blocked basement door open and ran hot water heater and checked the draft. Everything looked to be ok. The new furnace can't come fast enough.
  43. Replies
    12
    Views
    2,279

    I wanted to but the boss said fix it to get them...

    I wanted to but the boss said fix it to get them heat until we could get a new furnace and water heater installed. Made him put his name on it. If it wasn't 10 degrees outside would be shut down...
  44. Replies
    12
    Views
    2,279

    Yes that is exactly what that is but is a 90 not...

    Yes that is exactly what that is but is a 90 not a tee. All I can figure they didn't have a smaller water heater and needed a sharp 90 and just finished lunch and had two cans sitting in the truck...
  45. Replies
    12
    Views
    2,279

    One of the worst I've seen

    Yeah found that on the water heater in the same house. Was afraid to look at anything else in the house.
  46. Replies
    12
    Views
    2,279

    Was in a wide open basement and they face it...

    Was in a wide open basement and they face it toward the chimney so it is a pain to work on. Also motor went bad so the cut hole in the side and patched it back in with a filter.
  47. Replies
    12
    Views
    2,279

    One of the worst I've seen

    I ran across this gem today on a no heat call. The more I looked at it the more I found wrong.
    And yes is a downflow in a up flow application. And someone got paid to do this....
  48. Replies
    5
    Views
    1,180

    Yes I believe it is. Sure looked like it from the...

    Yes I believe it is. Sure looked like it from the distance. I didn't want to get to close to it.
  49. Replies
    5
    Views
    1,180

    What I seen the other day

    I wonder how well this is venting. I seen this as I I was sitting in a alley next to my customers house and had to take a picture. It is in a garage and not sure what it is venting.
    439811
  50. Replies
    6
    Views
    1,428

    Waterfunace 5 series with intellizone 2

    That looks like a very nice install. Couple thing I would have done different would turn the loop pumps around. I have seen the pumps sweet and with the electrical box on the bottom can hold water...