    Like everyone has said. Call a HVAC service tech....

    Like everyone has said. Call a HVAC service tech. They will find out what cause the problem and fix any damaged done by the water. Sounds like you haven't done this type of work, so don't try to do...
  2. Replies
    17
    Views
    1,282

    We are having the same problem here in southern...

    We are having the same problem here in southern Virginia. They stealing the condenser for the copper.
  3. Replies
    45
    Views
    4,143

    You should have called another HVAC contractor...

    You should have called another HVAC contractor that would do a manual J and d on your home. Sounds like the contractor you are using doesn't know what he is doing or care. You shouldn't have to keep...
  4. Replies
    13
    Views
    1,211

    Do you change the filter often or do you wait...

    Do you change the filter often or do you wait until the filter is fully coated in dust. This may be the reason dust is getting by the filter.
  5. Replies
    291
    Views
    12,849

    Manual D and J are a calculation formulas used to...

    Manual D and J are a calculation formulas used to size the proper unit and duct size for your house to heat and cool it efficiently. How many vents needed in each room. Return size. etc. You should...
  6. Replies
    13
    Views
    1,211

    Your return grill should have a lip inside it for...

    Your return grill should have a lip inside it for the filter to rest against. all filters are a 1/4 inch shorter then the size stated on them.
  7. Replies
    291
    Views
    12,849

    Goodman is a good unit. But if you are worried...

    Goodman is a good unit. But if you are worried about them. You said the HVAC company had 3 other brands they deal with. Have them give you a price estimate on each brand and let your wallet choose...
  8. Replies
    291
    Views
    12,849

    Stevoreno, You asked about your duct work....

    Stevoreno,
    You asked about your duct work. Your house being 46 years old and the duct work has not been changed. Your duct work might be under size for your new units. If it is the right size it...
  9. Replies
    15
    Views
    1,258

    already stated check that your drain line is...

    already stated check that your drain line is clear.
  10. Replies
    13
    Views
    1,048

    Sounds like you answered your own question. The...

    Sounds like you answered your own question. The installation looks good and you are happy with the results.
  11. Replies
    16
    Views
    1,459

    If you he used the existing lines what kind of...

    If you he used the existing lines what kind of problems would happen
  12. Replies
    20
    Views
    7,869

    Thanks for all the information. I was afraid the...

    Thanks for all the information. I was afraid the temperature and head pressure was to hi. That the compressor was getting to hot and would lock up/ burn out.

    I cleaned the condenser with a...
  13. Replies
    20
    Views
    7,869

    Everything I have read anything over 275 head...

    Everything I have read anything over 275 head pressure is a problem. Is this true.
  14. Replies
    20
    Views
    7,869

    inside temperature is 75 degree and outside temp....

    inside temperature is 75 degree and outside temp. is 98 degree. the line temp. is 124 at the evaporator.
  15. Replies
    20
    Views
    7,869

    liquid line temperature

    I just got my certification and I am still learning the trade. How hot can a liqiud line get on a hot day. If its 98 degrees outside.
  16. Replies
    10
    Views
    885

    Thank you for the help. I'm still learning. Just...

    Thank you for the help. I'm still learning. Just got my Universal certification last month. This is a great site for help. Hope you don't mind me asking for more help.
  17. Replies
    10
    Views
    885

    leak around condenser shut off valves

    Is there anyway to stop leaks around shut off valve caps . Both valves are leaking around the brass hex caps on top. Not the valve core caps.