Search:

Type: Posts; User: BigBacardi

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Thread: sight glass

    by BigBacardi
    Replies
    51
    Views
    3,565

    prime example of flashing is lo fire on a 2 stage...

    prime example of flashing is lo fire on a 2 stage compressor
    bubbles are normally present on lo fire.
    charging by sight glass is crazy for resi ac/hp
  2. Replies
    4
    Views
    345

    looking for dealer in canada

    looking for dealer in canada
  3. Replies
    4
    Views
    345

    Buderus Boilers

    Where in the world does one go to find a wholesaler for parts?
    WWG/Totaline no longer carries the brand.
    I have spent hours looking online and making calls
    Am I really this stoopid???
  4. Replies
    101
    Views
    5,823

    ahhh yes...remember the good ole days..........

    ahhh yes...remember the good ole days.......
    charge to 70 lbs on a hoy day, and beer can cold!

    system works purrrrrfect!!!!
  5. Haven't been here for awhile Forgot how good...

    Haven't been here for awhile
    Forgot how good info is

    Omg after 1.2 minutes I found the answer on removing broken schrader valve!!!

    Over 15 yrs in trade and finally broke my first one!!!!
  6. Replies
    14
    Views
    2,056

    high contactor open means bristol recip comp. u...

    high contactor open means bristol recip comp.
    u say only one contactor, which means copeland scroll.

    something is really messed up
  7. Replies
    11
    Views
    1,121

    80% furnace is not power vented it is induced...

    80% furnace is not power vented
    it is induced draft
    the inducer motors job is just that....induce a draft
    if u put manometer 18" downstream of furnace exhaust u will find vacuum, not pressure
  8. Replies
    25
    Views
    2,027

    lol pretty sure no matter what u do it will not...

    lol
    pretty sure no matter what u do it will not be good enuf for him....say goodbye and wash your hands of him....

    if not...repost in six months and let me know!!!!!
  9. carrier EZ FLEX fi;ter only way to go in my...

    carrier EZ FLEX fi;ter only way to go in my opinion
  10. Replies
    6
    Views
    805

    was just at a seminar...... dont remember the guy...

    was just at a seminar...... dont remember the guy saying that could vent 2 apliances tho......
  11. Replies
    61
    Views
    4,628

    been there, you stated earlier that in a 2 stage...

    been there, you stated earlier that in a 2 stage furnace the inducer doesnt slow down enuf????? and to much excess air.....am curious, cause all 2 stage furnaces have 2 stage inducer motors, wouldnt...
  12. Replies
    44
    Views
    4,293

    as far as liability goes, turn off gas cock and...

    as far as liability goes, turn off gas cock and power switch. make note on work order that furnace not safe to operate. when u leave and homeowner turns gas cock and power on....not your...
  13. Replies
    44
    Views
    4,293

    pic taken from 8 yr old bryant 340AAV042080348261

    pic taken from 8 yr old bryant 340AAV042080348261
  14. lol...had this happen to me once... on a maytag...

    lol...had this happen to me once... on a maytag mid.....the old tstat was lunched.....and dropping signal as ignitor was on...hence no fault code!!!!! it drove me nuts till i tried to jump furnace...
  15. Replies
    61
    Views
    4,628

    pressure correction factor .....if you have...

    pressure correction factor .....if you have anything above lo pressure...14 inches than a pressure correction factor must be performed. standard clocking tables are made with lo pressure data.
  16. Replies
    61
    Views
    4,628

    curious....you said you clocked furnace....u have...

    curious....you said you clocked furnace....u have lo pressure gas...or 2 lb?????

    if you have 2 lb did you forget to make allowance for pressure allowance of xxxxxx?

    cause if you forget pressure...
  17. Replies
    72
    Views
    8,165

    the solution is to just replace the parts that u...

    the solution is to just replace the parts that u havent done yet...... eventually u will fix problem
  18. Replies
    20
    Views
    1,144

    what were choices for answers? and zero...

    what were choices for answers?

    and zero energy???? me thinks impossible?
  19. Replies
    9
    Views
    1,362

    LOL u went back and corrected the situation...

    LOL u went back and corrected the situation tho...right?
  20. Replies
    9
    Views
    1,362

    Hot air coming from Return Air Ducting?

    So i got a phone call from a buddy today....A friend of a friend asked me to do a retrofit(on the side)

    I dont mind making a shwack load of cash in a short period of time. As dont have any...
  21. Replies
    30
    Views
    3,895

    i remember my first time with a problem...

    i remember my first time with a problem similar....the disc was so rotten that it wasnt there. i was pulling my hair outa head untill some other guy said that the opening should be 1.5 inches.....i...
  22. plugged...maybe.....corroded and comprimised...

    plugged...maybe.....corroded and comprimised absolutely....furnace is done son.
  23. Replies
    13
    Views
    2,128

    mr bill...... after 14thousand posts......the red...

    mr bill...... after 14thousand posts......the red wire????? and the white wire?????

    OMFG......

    im in trouble cause i only got a white and a black wire.....I dunno whAT to do?
  24. Replies
    14
    Views
    1,609

    and...golden rule.... never ever ever...zone...

    and...golden rule....

    never ever ever...zone single stage equipment....no matter the size
  25. Replies
    7
    Views
    947

    why???? when you go to dr...does he show you...

    why????


    when you go to dr...does he show you a book of what is wrong with you????

    if you customer doesnot believe you then you have done a piss poor job.

    you do not need to explain to them...