Search:

Type: Posts; User: md-01-11376

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    17
    Views
    927

    Have the system replaced by a professional. There...

    Have the system replaced by a professional. There must be a problem with the installation of that system,because it didn't last.
  2. Replies
    10
    Views
    463

    Geothermal heatpumps generate enough hot water...

    Geothermal heatpumps generate enough hot water for raidiant systems and are an option with most makes
  3. Replies
    11
    Views
    2,176

    The furnace in front serves the second floor, the...

    The furnace in front serves the second floor, the other does the first floor. 5000 sq. ft.
    There is no ac. An older couple in their 70's live there,and my guess why they do not is older folks like...
  4. Replies
    11
    Views
    2,176

    Oil Furnace

    Job complete. Before and after.
  5. It would have looked better with the condensate...

    It would have looked better with the condensate to the left between the return and furnace.
  6. The end cap for the coil door is cool.I never...

    The end cap for the coil door is cool.I never install uv light thats cool also.
  7. Replies
    7
    Views
    2,781

    Thanks, now I can get the part # and place order...

    Thanks, now I can get the part # and place order tomorrow.
  8. Replies
    11
    Views
    2,176

    Thanks for the compliment. I figure I will be...

    Thanks for the compliment. I figure I will be back there to service in a year and also try to keep a customer. Plus there is more equipment through out the house that will need replaced one day.
  9. Replies
    7
    Views
    2,781

    Model # was hard to read I got ycaz ld3-46-pc

    Model # was hard to read I got ycaz ld3-46-pc
  10. Replies
    7
    Views
    2,781

    Model #

    some one scrached over the model # here is what I got ycaz ld3-46 pc ?
  11. Replies
    11
    Views
    2,176

    Low boy

    The old unit was the same way, I know, it is a little close. There is enough room to remove burner, but if the heat exchange needs replace I guess the ducts would need disconnected. I was there today...
  12. Replies
    7
    Views
    2,781

    where do I find info on York ycaz

    I would like to find a pdf file on York ycaz chiller and the Isn recip pack control center. I need to replace ambient sensor and would like to learn more about this unit. Any help would be appeciated.
  13. Replies
    11
    Views
    2,176

    barometric draft

    Thanks for the info. Yes,I meant Barometric draft control. Thanks.
  14. Replies
    32
    Views
    4,273

    Duct

    Could you have turned the furnace 90 degrees drop the return on one side?
  15. Replies
    11
    Views
    2,176

    Lennox Low Boy Oil

    I have a question about the draft diverter, there are 2 of these furnaces that are connected to a common 10" flue, does any one know if I can install a draft diverter on each unit ? I'm not finish...
  16. Replies
    3
    Views
    1,397

    ge halogen leak detector

    Can a ge halogen leak detector be used to detect a leak on a r 410a system?
  17. Nice work. I never seen those outside before. I...

    Nice work. I never seen those outside before. I know the doors on them are sealed so I dont see why there should be any problem at all.
  18. i realized that after I posed comment .

    i realized that after I posed comment .
  19. I hope the water doesn't freeze and explode the...

    I hope the water doesn't freeze and explode the heat exchanger and water pipes on those water heaters this winter.
  20. Replies
    9
    Views
    1,790

    Im from Baltimore and the trunk is 16". This job...

    Im from Baltimore and the trunk is 16". This job was for Paramount Die near Aberdeen. Off 0f 543 Near the Mercedes building
  21. Replies
    5
    Views
    1,143

    trane roof top

    the return and supply are on the wrong sides on one unit the other was ok, one of my suggestions to the boss was to install the unit on the other side on a new curb. there will be a sheet metal cover...
  22. Replies
    5
    Views
    1,143

    trane roof top

    This was one of the tightest duct jobs I have ever done. Going back tomorrow to finish. I hope the return air works out 16+12 sq to 12+12 radius 90 and a 16+12 to 16+10 transition to install. 30,000...
  23. Replies
    9
    Views
    1,790

    Return

    I did install a 2' of and and grille. Thank you. The person we were working for was very picky.
  24. Replies
    7
    Views
    1,896

    chimney liner

    furnace cementer
  25. Replies
    22
    Views
    2,703

    chimney liner

    furnace cementer
Results 1 to 25 of 55