Search:

Type: Posts; User: leaflying

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    57
    Views
    4,174

    No experience on TAC. Is it mainly LON? For...

    No experience on TAC. Is it mainly LON?

    For the rest,
    if you like LON instead of BACnet --> Distech
    if you like graphical programming instead of line code --> Distech
    if you like to be able to...
  2. Replies
    18
    Views
    2,230

    Trust me, they are trying this very hard...but...

    Trust me, they are trying this very hard...but there may be something that cannot be simply stopped by management's will. This reminds me of Nokia. They tried hard on Symbian instead of Meego.
  3. Replies
    9
    Views
    836

    copy everything under user folder to same place...

    copy everything under user folder to same place under new installation folder.
  4. Replies
    30
    Views
    4,452

    I like portable apps. Nice to have it under my...

    I like portable apps. Nice to have it under my tools folder. Thanks.:cheers:
  5. Replies
    16
    Views
    2,184

    SNVT_Count_inc can only represent an integer from...

    SNVT_Count_inc can only represent an integer from -32,768 to 32,767. There is no 2-byte SNVT with a resolution of 0.1 in SNVT_Count_xxx family. That's why sometimes I use SNVT_press.

    I guess your...
  6. Replies
    16
    Views
    2,184

    Sorry, I was referring to use use SNVT_Press as...

    Sorry, I was referring to use use SNVT_Press as "the universal SNVT type of choice".
  7. Replies
    16
    Views
    2,184

    Because sometimes the NV type one wants cannot be...

    Because sometimes the NV type one wants cannot be found in STANDARD NV types, especially enumeration types. Describing the World by < 200 concrete NV types is mission impossible. It needs certain...
  8. Replies
    16
    Views
    2,184

    Depends on what type of controllers you are...

    Depends on what type of controllers you are using. When applicable, it's up to you to choose right type of SNVT as "the universal SNVT type of choice". Sometimes I use SNVT_Press_P. Use with caution,...
  9. Replies
    15
    Views
    3,058

    Tridum is a good adapted child who hasn't been...

    Tridum is a good adapted child who hasn't been seriously affected by big H culture virus. True Honeywell side has outsourced quite a lot overseas, including Sypder software development.
  10. Replies
    15
    Views
    3,058

    Tridium didn't do this. This is developed by...

    Tridium didn't do this. This is developed by Honeywell side, with big difference in quality...
  11. Thread: Floor Plans

    by leaflying
    Replies
    74
    Views
    7,567

    Usage of urinals (1 of 4 in blue is in using,...

    Usage of urinals (1 of 4 in blue is in using, left side).
    Occupancy of stalls (1 of 3 in yellow is occupied, right side).

    Powered by 3D.:yes:
  12. Thread: Floor Plans

    by leaflying
    Replies
    74
    Views
    7,567

    Area served by color code. Mouse over to show...

    Area served by color code.
    Mouse over to show serving VAV box and AHU. Hyperlinks to each box and AHU.
    Room number show/hide.

    No room temp on this one. But I have another example.

    Similar...
  13. Thread: Floor Plans

    by leaflying
    Replies
    74
    Views
    7,567

    Keyword: analog profile starfield Johnson...

    Keyword:
    analog profile
    starfield
    Johnson Controls

    Yeah, they had something creative and ahead of time back then. As an outsider, I was amazed.
  14. Replies
    50
    Views
    4,066

    The construction unit reminds me of AT-AT in Star...

    The construction unit reminds me of AT-AT in Star war.

    http://loyalkng.com/wp-content/uploads/2010/02/star-wars-at-at-death-star-speeder-bike-george-lucas-concept-art-empire.jpg
  15. I doubt it. I don't have time to check IEC-61499...

    I doubt it. I don't have time to check IEC-61499 but is wondering if it can handle array operations, or identify the second highest temperature readings in a group and to which VAV controller it...
  16. Replies
    30
    Views
    3,051

    I don't have this issue on my systems. Sorry,...

    I don't have this issue on my systems. Sorry, can't help.
  17. Replies
    30
    Views
    3,051

    File-Open Query, in "in" box, choose the trend...

    File-Open Query, in "in" box, choose the trend you want to see.
  18. Replies
    15
    Views
    1,902

    Exact same steps eparizher uses. Use Photoshop...

    Exact same steps eparizher uses. Use Photoshop instead of PaintShop Pro.
  19. Replies
    10
    Views
    2,016

    Replace CP with BAC, you should get a clue of who...

    Replace CP with BAC, you should get a clue of who the OEM is. Similarly, CP series and BAC series are not replaceable.
  20. Replies
    10
    Views
    2,016

    ComfortPoint means different things in different...

    ComfortPoint means different things in different regions. In NA, JACE + OEM BACnet controllers most likely.
  21. Replies
    17
    Views
    5,772

    Meaning you want to re-engineer the Lon network...

    Meaning you want to re-engineer the Lon network every time after CARE is used for small NV changes.
  22. Thread: Graphics

    by leaflying
    Replies
    3
    Views
    861

    Optiview has been a standard option for York...

    Optiview has been a standard option for York chillers for years.

    http://media.york.com/media/optiview_panel_html_show/html/sOHomeSSS.html
  23. Replies
    14
    Views
    1,896

    I can ask this question to Tridium during Niagara...

    I can ask this question to Tridium during Niagara Summit.

    I haven't created BACnet inputs and outputs in a foreign tool, so am curious. Device type in Bacnet Input is a text description only. Do...
  24. Replies
    14
    Views
    1,896

    I don't think Tridium support BACnet CreateObject...

    I don't think Tridium support BACnet CreateObject and DeleteObject Services. At least not that I am aware of.


    There are 2 aspects.

    One, after all objects discovered into the Niagara...
  25. Replies
    14
    Views
    1,896

    If the given controller manufacturer provides LNS...

    If the given controller manufacturer provides LNS plug-ins, then theoretically any LNS client software from other manufacturers can launch the plug-ins and create new objects. The learning curve of...
  26. Replies
    62
    Views
    9,220

    To go beyond organic growth and satisfy book...

    To go beyond organic growth and satisfy book worms on Wall street.
  27. Replies
    23
    Views
    1,778

    It's about one month away now. I will go to the...

    It's about one month away now. I will go to the summit and am wondering who else has registered?
  28. Replies
    9
    Views
    745

    You can handle that in a program object.

    You can handle that in a program object.
  29. Replies
    9
    Views
    1,193

    Hi BACnet, This meter is on BACnet/IP. The...

    Hi BACnet,

    This meter is on BACnet/IP. The whole section 5 is titled as "BACnet IP interface". And you are probably right on its BTL status.
  30. Replies
    9
    Views
    1,193

    It seems this is pretty easy to be found online,...

    It seems this is pretty easy to be found online, please check section 5.7 of the document from link below.
    ...
  31. Replies
    8
    Views
    1,038

    Honeywell XL50 or XL500 has internal schedule. A...

    Honeywell XL50 or XL500 has internal schedule. A function in EBI called Global Schedule can access and edit them. Bacnet schedule in BACnet controllers can be accessed too.

    Maybe field...
  32. Replies
    5
    Views
    513

    There is no restriction of where this schedule...

    There is no restriction of where this schedule can be created, but it's more convenient to put it somewhere logical and easily to be found, e.g. the 'main building' folder you mentioned.
  33. Replies
    5
    Views
    513

    Question #2: You can create one schedule and...

    Question #2:

    You can create one schedule and "link to" multiple nvi from different controller. If the NV type of TodEvent, you can link the schedule to TodEvent object in KitLon and from this...
  34. Replies
    5
    Views
    513

    I am not a typical EC-BOS user but here are my 2...

    I am not a typical EC-BOS user but here are my 2 cents
    Question 1: Gfx program editor runs locally on your PC and connect to JACE through BcpServer in the station, default port number 1930. So I...
  35. Replies
    109
    Views
    10,472

    Writing posts sometimes is complicated and...

    Writing posts sometimes is complicated and misleading. It takes both writer and reader great efforts to communicate correctly. You thought you understand, but do you really read out what was written?...
  36. Replies
    9
    Views
    1,346

    Oops, not a good news to me. Hope this is not...

    Oops, not a good news to me. Hope this is not true.
  37. Replies
    6
    Views
    1,881

    I had a glimpse of Wonderware InTouch years ago...

    I had a glimpse of Wonderware InTouch years ago and it's impressive. But I don't have hands-on experience on that.

    Nowadays, exciting frontend experiences are mostly from Flash/Flex or Silverlight...
  38. Replies
    109
    Views
    10,472

    You can say BS to "few lines of code" and...

    You can say BS to "few lines of code" and "standard practice" statements. That's your freedom. And it is, it's no longer "few lines of code". Most likely, it would be "copy and paste" now. It's such...
  39. Replies
    109
    Views
    10,472

    I believe most manual operation experience can be...

    I believe most manual operation experience can be digitalized into codes. But I need to be a sophisticated "owner" to know those. Most of us program and fine tune closed loops but work and learn...
  40. Replies
    109
    Views
    10,472

    I put online/offline judgment in my Niagara AX...

    I put online/offline judgment in my Niagara AX program object. When free programmable VAV controllers are used, I write prejudgments (considering various temperature/setpoint and flow/setpoint...
  41. Replies
    109
    Views
    10,472

    It's amazing to see, from this small topic, how...

    It's amazing to see, from this small topic, how various the opinions are and how persistent people are behind their own opinion, just like religious beliefs.

    Static pressure setpoint reset is...
  42. Replies
    6
    Views
    1,003

    I wouldn't say "optimize the BAS operation" but...

    I wouldn't say "optimize the BAS operation" but "use BAS to optimize the mech/elec system operation". So the answer/knowledge is not in BAS but in those systems under control.
  43. Replies
    109
    Views
    10,472

    This is a good question. A full study of...

    This is a good question. A full study of sensor-less VAV control has been done in last century by Japaneses. And I tried this in one of my job. The static pressure sensor can be a boundary limiter to...
  44. Replies
    109
    Views
    10,472

    I would agree with you if you don't change gear...

    I would agree with you if you don't change gear when driving from highway to local road and vice verse.
  45. The normal BACnet feature is BACnet client and...

    The normal BACnet feature is BACnet client and Enterprise Connectivity is to enable BACnet server (export =true).
  46. Replies
    28
    Views
    4,540

    I'll second this.

    I'll second this.
  47. I am sorry to say this but whoever told you R2 is...

    I am sorry to say this but whoever told you R2 is bad simply only knows AX and is intimidated by R2, and maybe have no idea of what R2 is.
    1) R2 is as open and effective as AX for an integrator who...
  48. Replies
    22
    Views
    3,707

    Get the station output after starting the station...

    Get the station output after starting the station and before the station connection
    run netstat and see if 1911 is listening
    Do you have any web service running (e.g. IIS)?
    And why...
  49. Replies
    2
    Views
    735

    Use BRelTime.

    Use BRelTime.
  50. Replies
    22
    Views
    3,707

    What's your firewall setting?

    What's your firewall setting?